Biosensors for environmental applications:: Future development trends

被引:108
作者
Rodriguez-Mozaz, S
Marco, MP
de Alda, MJL
Barceló, D
机构
[1] CSIC, IIQAB, Dept Environm Chem, ES-08034 Barcelona, Spain
[2] CSIC, IIQAB, Dept Biol Organ Chem, ES-08034 Barcelona, Spain
关键词
D O I
10.1351/pac200476040723
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Biosensors can be excellent analytical tools for monitoring programs working to implement legislation. In this article, biosensors for environmental analysis and monitoring are extensively reviewed. Examples of biosensors for the most important families of environmental Pollutants, including some commercial devices, are presented. Finally, future trends in biosensor development are discussed. In this context, bioelectronics, nanotechnology, miniaturization, and especially biotechnology seem to be growing areas that will have a marked influence on the development of new biosensing strategies in the next future.
引用
收藏
页码:723 / 752
页数:30
相关论文
共 173 条
[1]   SPR fibre sensor sensitised by fluoroxiloxane polymers [J].
Abdelghani, A ;
Jaffrezic-Renault, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :117-123
[2]   High-performance liquid chromatographic determination of phenols using a tyrosinase-based amperometric biosensor detection system [J].
Adeyoju, O ;
Iwuoha, EI ;
Smyth, MR ;
Leech, D .
ANALYST, 1996, 121 (12) :1885-1889
[3]   Use of optical biosensor technology to study immunological cross-reactivity between different sulfonamide drugs [J].
Ahmad, A ;
Ramakrishnan, A ;
McLean, MA ;
Li, DB ;
Rock, MT ;
Karim, A ;
Breau, AP .
ANALYTICAL BIOCHEMISTRY, 2002, 300 (02) :177-184
[4]   Detection of sulphamethazine with an optical biosensor and anti-idiotypic antibodies [J].
Akkoyun, A ;
Kohen, VF ;
Bilitewski, U .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 70 (1-3) :12-18
[5]   FLUORESCENCE MONITORING OF A BENZO[A]PYRENE METABOLITE USING A REGENERABLE IMMUNOCHEMICAL-BASED FIBEROPTIC SENSOR [J].
ALARIE, JP ;
BOWYER, JR ;
SEPANIAK, MJ ;
HOYT, AM ;
VO-DINH, T .
ANALYTICA CHIMICA ACTA, 1990, 236 (02) :237-244
[6]   Market analysis of biosensors for food safety [J].
Alocilja, EC ;
Radke, SM .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :841-846
[7]   A portable fiber-optic pesticide biosensor based on immobilized cholinesterase and sol-gel entrapped bromcresol purple for in-field use [J].
Andreou, VG ;
Clonis, YD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (1-2) :61-69
[8]   Fibre-optic pesticide biosensor based on covalently immobilized acetylcholinesterase and thymol blue [J].
Andres, RT ;
Narayanaswamy, R .
TALANTA, 1997, 44 (08) :1335-1352
[9]  
ANGERER J, 1993, ORGANOHALOGEN COMPD, V14, P163
[10]   A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution [J].
Bachmann, TT ;
Schmid, RD .
ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) :95-103