Magnetic resonance electrical impedance tomography of the breast: A simulation study on basic imaging setup

被引:1
|
作者
Lee, B. I.
Oh, S. H.
Kim, T. -S.
Woo, E. J.
Lee, S. Y.
Kwon, O.
Seo, J. K.
机构
来源
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2005年
关键词
breast MREIT; conductivity image; breast tumor;
D O I
10.1109/IEMBS.2005.1615435
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance electrical impedance tomography (MRFIT) has been developed as a new medical imaging modality providing high-resolution conductivity and current density images. This paper is about MREIT of the breast. To show the feasibility of breast MIREIT, we carried numerical simulations and breast phantom experiments. We found that an anomaly with 4mm diameter can be visualized in a reconstructed conductivity image using 5mA injection current if the SNR of the corresponding MR magnitude image is at least 150. We propose a desirable electrode configuration and show our first experimental results of the breast MREIT. Developing an RF coil for the breast MREIT, we plan to conduct various experimental studies including tissue phantoms.
引用
收藏
页码:4377 / 4380
页数:4
相关论文
共 50 条
  • [21] Simulations and phantom evaluations of magnetic resonance electrical impedance tomography (MREIT) for breast cancer detection
    Sadleir, Rosalind J.
    Sajib, Saurav Z. K.
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    JOURNAL OF MAGNETIC RESONANCE, 2013, 230 : 40 - 49
  • [22] Simulation on two-step magnetic resonance electrical impedance tomography of brain anomaly tissues
    College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
    不详
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2008, 42 (04): : 661 - 666
  • [23] Validation of conductivity tensor imaging against diffusion tensor magnetic resonance electrical impedance tomography
    Sajib, S. Z. K.
    Chauhan, M.
    Sahu, S.
    Boakye, E.
    Sadleir, R. J.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [24] Fast conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) for RF ablation monitoring
    Kwon, Oh In
    Chauhan, Munish
    Kim, Hyung Joong
    Jeong, Woo Chul
    Wi, Hun
    Oh, Tong In
    Woo, Eung Je
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2014, 30 (07) : 447 - 455
  • [25] Noninvasive imaging of bioimpedance distribution by means of current reconstruction magnetic resonance electrical impedance tomography
    Gao, Nuo
    He, Bin
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (05) : 1530 - 1538
  • [26] Resolution and contrast in magnetic resonance electrical impedance tomography (MREIT) and its application to cancer imaging
    Muftuler, LT
    Hamamura, M
    Birgul, O
    Nalcioglu, O
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2004, 3 (06) : 599 - 609
  • [27] Electrical conductivity imaging using gradient Bz decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)
    Park, C
    Kwon, O
    Woo, EJ
    Seo, JK
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) : 388 - 394
  • [28] The basic principles of computed tomography and magnetic resonance imaging
    Caldemeyer, KS
    Buckwalter, KA
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1999, 41 (05) : 768 - 771
  • [29] Induced current magnetic resonance-electrical impedance tomography
    Özparlak, L
    Ider, YZ
    PHYSIOLOGICAL MEASUREMENT, 2005, 26 (02) : S289 - S305
  • [30] Inverse problem of inductive magnetic resonance electrical impedance tomography
    Liu, Guoqiang
    Meng, Meng
    Wang, Hao
    Jiang, Lingtong
    Li, Shiqiang
    2007 JOINT MEETING OF THE 6TH INTERNATIONAL SYMPOSIUM ON NONINVASIVE FUNCTIONAL SOURCE IMAGING OF THE BRAIN AND HEART AND THE INTERNATIONAL CONFERENCE ON FUNCTIONAL BIOMEDICAL IMAGING, 2007, : 147 - 149