Magnetic resonance electrical impedance tomography of the breast: A simulation study on basic imaging setup

被引:1
|
作者
Lee, B. I.
Oh, S. H.
Kim, T. -S.
Woo, E. J.
Lee, S. Y.
Kwon, O.
Seo, J. K.
机构
来源
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7 | 2005年
关键词
breast MREIT; conductivity image; breast tumor;
D O I
10.1109/IEMBS.2005.1615435
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance electrical impedance tomography (MRFIT) has been developed as a new medical imaging modality providing high-resolution conductivity and current density images. This paper is about MREIT of the breast. To show the feasibility of breast MIREIT, we carried numerical simulations and breast phantom experiments. We found that an anomaly with 4mm diameter can be visualized in a reconstructed conductivity image using 5mA injection current if the SNR of the corresponding MR magnitude image is at least 150. We propose a desirable electrode configuration and show our first experimental results of the breast MREIT. Developing an RF coil for the breast MREIT, we plan to conduct various experimental studies including tissue phantoms.
引用
收藏
页码:4377 / 4380
页数:4
相关论文
共 50 条
  • [1] Basic setup for breast conductivity imaging using magnetic resonance electrical impedance tomography
    Lee, BI
    Oh, SH
    Kim, TS
    Woo, EJ
    Lee, SY
    Kwon, O
    Seo, JK
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (02): : 443 - 455
  • [2] Magnetic resonance-electrical impedance tomography in breast cancer imaging
    Birgul, Ozlem
    Hamamura, Mark J.
    Muftuler, L. Turgan
    Nalcioglu, Orhan
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 686 - +
  • [3] Magnetic Resonance Driven Electrical Impedance Tomography: A Simulation Study
    Negishi, Michiro
    Tong, Tangji
    Constable, R. Todd
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 828 - 837
  • [4] Fast imaging for magnetic resonance electrical impedance tomography
    Hamamura, Mark J.
    Muftuler, L. Tugan
    MAGNETIC RESONANCE IMAGING, 2008, 26 (06) : 739 - 745
  • [5] Coregistration of electrical impedance tomography and magnetic resonance imaging
    Halter, R. J.
    Manwaring, P.
    Hartov, A.
    Paulsen, K. D.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 416 - 419
  • [6] Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)
    Oh, SH
    Han, JY
    Lee, SY
    Cho, MH
    Lee, BI
    Woo, EJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 875 - 878
  • [7] Magnetic Resonance Electrical Impedance Tomography For Anisotropic Conductivity Imaging
    Degirmenci, E.
    Eyuboglu, B. M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 728 - 731
  • [8] Magnetic resonance electrical impedance tomography (MREIT):: Simulation study of J-substitution algorithm
    Kwon, O
    Woo, EJ
    Yoon, JR
    Seo, JK
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (02) : 160 - 167
  • [9] Multi-frequency Electrical Impedance Tomography and Magnetic Resonance Electrical Impedance Tomography
    Seo, Jin Keun
    Woo, Eung Je
    MATHEMATICAL MODELING IN BIOMEDICAL IMAGING I: ELECTRICAL AND ULTRASOUND TOMOGRAPHIES, ANOMALY DETECTION, AND BRAIN IMAGING, 2009, 1983 : 1 - 71
  • [10] A Simulation Study on Induced Current Magnetic Resonance Electrical Impedance Tomography of Anisotropic Brain Tissues
    Liu, Yang
    Dai, Songshi
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 75 - 77