Updated Australian diagnostic reference levels for adult CT

被引:41
作者
Lee, Kam L. [1 ]
Beveridge, Toby [1 ]
Sanagou, Masoumeh [1 ]
Thomas, Peter [1 ]
机构
[1] Australian Radiat Protect & Nucl Safety Agcy, 619 Lower Plenty Rd, Yallambie, Vic 3085, Australia
关键词
Computed tomography; diagnostic reference level; dose survey; optimisation; radiation protection; COMPUTED-TOMOGRAPHY;
D O I
10.1002/jmrs.372
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction In 2018, ARPANSA published updated national DRLs for adult CT, which were first published in 2012, and augmented the national DRL categories. This paper presents the updated national DRLs and describes the process by which they were produced. Methods Examine patient survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS). Determine the quartiles of the distributions of median survey dose metrics with categorisation by procedure type. Engage a liaison panel representing the radiology professions to review procedure categories and recommend revised national DRLs. The revised NDRL procedure categories are: head (non-contrast brain (trauma/headache)), cervical spine (Non-contrast (trauma)), soft-tissue neck (post-contrast (oncology)), chest (post-contrast (oncology)), abdomen-pelvis (post-contrast (oncology)), kidney-ureter-bladder (non-contrast (suspected renal colic)), chest-abdomen-pelvis (post-contrast (oncology)) and lumbar spine (non-contrast (degenerative pain)). Results The existing six procedure categories were revised and refined. Updated Australian national diagnostic reference levels for adult CT were recommended and endorsed for eight procedure categories: head (52 mGy/880 mGycm), cervical spine (23 mGy/470 mGycm),soft-tissue neck (17 mGy/450 mGycm), chest (10 mGy/390 mGycm), abdomen-pelvis (13 mGy/600 mGycm), kidney-ureter-bladder (13 mGy/600 mGycm), chest-abdomen-pelvis (11 mGy/940 mGycm) and lumbar spine (26 mGy/670 mGycm). The updated national DRLs are between 12 and 26% lower than the previous DRLs for dose-length product and between 13 and 63% lower for volume computed tomography dose index. Conclusions Australian national DRLs for adult CT have been reviewed and revised. The revised national DRLs are lower, better reflecting current practice among imaging facilities in Australia. The revised Australian national DRLs are similar to those in other developed countries.
引用
收藏
页码:5 / 15
页数:11
相关论文
共 26 条
  • [1] [Anonymous], 2015, 2011 2013 NATL DIAGN
  • [2] [Anonymous], ANN ICRP
  • [3] [Anonymous], 1991, NRPBR249
  • [4] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [5] Bundesamt fur Strahlenschutz, 2016, BEK AKT DIAGN REF DI
  • [6] Faulkner, 1991, NRPBR248
  • [7] Establishment of CT diagnostic reference levels in Ireland
    Foley, S. J.
    McEntee, M. F.
    Rainford, L. A.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018) : 1390 - 1397
  • [8] Diagnostic reference level of computed tomography (CT) in japan
    Fukushima, Yasuhiro
    Tsushima, Yoshito
    Takei, Hiroyuki
    Taketomi-Takahashi, Ayako
    Otake, Hidenori
    Endo, Keigo
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 51 - 57
  • [9] National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK
    Hart, D.
    Hillier, M. C.
    Wall, B. F.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (973) : 1 - 12
  • [10] New diagnostic reference level for full-field digital mammography units
    Hauge, I. H. R.
    Bredholt, K.
    Olerud, H. M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (02) : 181 - 192