Liquid chromatography-tandem mass spectrometric assay for the light sensitive survivin suppressant sepantronium bromide (YM155) in mouse plasma

被引:2
|
作者
Dolman, M. Emmy M. [1 ]
den Hartog, Ilona J. M. [1 ]
Molenaar, Jan J. [1 ]
Schellens, Jan H. M. [2 ,3 ]
Beijnen, Jos H. [2 ,3 ,4 ]
Sparidans, Rolf W. [2 ]
机构
[1] Univ Amsterdam, Amsterdam Med Ctr, Dept Oncogen, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Utrecht, Fac Sci, Dept Pharmaceut Sci, Div Pharmacoepidemiol & Clin Pharmacol, NL-3584 CG Utrecht, Netherlands
[3] Netherlands Canc Inst, Dept Clin Pharmacol, NL-1066 CX Amsterdam, Netherlands
[4] Slotervaart Hosp, Dept Pharm & Pharmacol, NL-1066 EC Amsterdam, Netherlands
关键词
Sepantronium bromide; Survivin suppressant; LC-MS/MS; Plasma; NEUROBLASTOMA;
D O I
10.1016/j.jpba.2014.01.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for sepantronium bromide (YM155), an inhibitor of survivin, was developed and validated. Under reduced light exposure, plasma samples were pre-treated using protein precipitation with acetonitrile containing AT7519 as internal standard. After dilution with water, the extract was directly injected into the reversed-phase liquid chromatographic system. The eluate was transferred into the electrospray interface with positive ionization and compounds detected in the selected reaction monitoring mode of a triple quadrupole mass spectrometer. The assay was validated in a 0.5-100 ng/ml calibration range with r(2) = 0.9981 +/- 0.0007 using double logarithmic calibration (n = 5). Within day precisions (n = 6) were 3.6-8.8% and between day (3 days; n = 18) precisions 6.5-11.1%. Accuracies were between 92 and 111% for the whole calibration range. The light sensitive drug sepantronium was sufficiently stable under all relevant analytical conditions. Finally, the assay was successfully used to determine plasma drug levels in mice after administration of sepantronium bromide by continuous infusion from subcutaneously implanted osmotic pumps. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:144 / 148
页数:5
相关论文
共 50 条
  • [31] Liquid chromatography-tandem mass spectrometric analysis of stobadine in human plasma
    Abdel-Hamid, ME
    Novotny, L
    Stankovicova, M
    Benes, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 383 - 393
  • [32] Sensitive and rapid liquid chromatography/tandem mass spectrometric assay for the quantification of chloroquine in dog plasma
    Singhal, Puran
    Gaur, Ashwani
    Behl, Vanita
    Gautam, Anirudh
    Varshney, Brijesh
    Paliwal, Jyoti
    Batra, Vijay
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 293 - 299
  • [33] A rapid and sensitive liquid chromatography-tandem mass spectrometric assay for moexipril, an angiotensin-converting enzyme inhibitor in human plasma
    Karra, Vijaya Kumari
    Mullangi, Ramesh
    Pilli, Nageswara Rao
    Inamadugu, Jaswanth Kumar
    Ravi, Vasu Babu
    Rao, J. V. L. N. Seshagiri
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (12) : 1552 - 1558
  • [34] Sensitive and rapid liquid chromatography/tandem mass spectrometric assay for the quantification of piperaquine in human plasma
    Paliwal, Jyoti
    Batra, Vijay
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 859 (01): : 24 - 29
  • [35] A rapid and sensitive liquid chromatography-tandem mass spectrometric assay for cycloserine in 50 μL of human plasma: Its pharmacokinetic application
    Polagani, Srinivasa Rao
    Pilli, Nageswara Rao
    Maddela, Rambabu
    Gajula, Ramakrishna
    Gandu, Venkateswarlu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 76 : 21 - 27
  • [36] A flexible and high throughput liquid chromatography-tandem mass spectrometric assay for the quantitation of telcagepant in human plasma
    Du, Lihong
    Miller-Stein, Cynthia M.
    Valesky, Robert J.
    Martucci, Ashley N.
    Woolf, Eric J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (14-15): : 1465 - 1471
  • [37] Liquid chromatography-tandem mass spectrometric assay for determination of unstable arecoline in rat plasma and its application
    Pan, Hong
    Huang, Linyan
    Li, Yi
    Zhou, Xumei
    Lu, Yuanfu
    Shi, Fuguo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1070 : 112 - 116
  • [38] Liquid chromatography-tandem mass spectrometric assay for eltrombopag in 50 μL of human plasma: A pharmacokinetic study
    Maddela, Rambabu
    Gajula, Ramakrishna
    Pilli, Nageswara Rao
    Siddiraju, Sridhar
    Maddela, Srinubabu
    Makula, Ajitha
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 98 : 68 - 73
  • [39] Liquid chromatography-tandem mass spectrometric assay for the nucleoside reverse transcriptase inhibitor emtricitabine in human plasma
    Sparidans, Rolf W.
    Prins, Jan M.
    Schellens, Jan H. M.
    Beijnen, Jos H.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) : 621 - 627
  • [40] Liquid chromatography-tandem mass spectrometric assay for the determination of vaccarin in rat plasma: application to a pharmacokinetic study
    Yang, Guilin
    Zhang, Nan
    Wang, Tiance
    Zhang, Shudong
    Xu, Rihao
    Zhu, Zhicheng
    Liu, Kexiang
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (12) : 1789 - 1794