Off-line mixed-mode liquid chromatography coupled with reversed phase high performance liquid chromatography-high resolution mass spectrometry to improve coverage in lipidomics analysis

被引:37
|
作者
Narvaez-Rivas, Monica [1 ]
Ngoc Vu [2 ]
Chen, Guan-Yuan [1 ]
Zhang, Qibin [1 ,2 ]
机构
[1] Univ North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus,500 Laureate Way, Kannapolis, NC 28081 USA
[2] Univ North Carolina Greensboro, Dept Chem & Biochem, Greensboro, NC 27412 USA
基金
美国国家卫生研究院;
关键词
Rat plasma lipidome; Rat liver lipidome; Off-line two-dimensional liquid chromatography; Untargeted lipidomics; Monolithic column; Accucore C30 column; LIGHT-SCATTERING DETECTOR; MULTIVARIATE DATA-ANALYSIS; LC-QTOF-MS; HUMAN PLASMA; SEPARATION; IDENTIFICATION; PHOSPHOLIPIDS; TISSUES; LIPIDS; QUANTIFICATION;
D O I
10.1016/j.aca.2016.12.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The confident identification and in-depth profiling of molecular lipid species remain to be a challenge in lipidomics analysis. In this work, an off-line two-dimensional mixed-mode and reversed-phase liquid chromatography (RPLC) method combined with high-field quadrupole orbitrap mass spectrometer (Q Exactive HF) was developed to profile lipids from complex biological samples. In the first dimension, 22 different lipid classes were separated on a monolithic silica column with elution order from neutral to polar lipids. A total of 13 fractions were collected and run on a RPLC 00 column in the second dimension for further separation of the lipid molecular species based on their hydrophobicity, with the elution order being determined by both the length and degree of unsaturation in the fatty-acyl chain. The method was applied to analyze lipids extracted from rat plasma and rat liver. Fatty acid methyl ester analysis by gas chromatography-mass spectrometry was used to identify the fatty acyls from total lipid extracts, which provided a more confident identification of the lipid species present in these samples. More than 800 lipids were identified in each sample and their molecular structures were confidentially confirmed using tandem mass spectrometry (MS/MS). The number of lipid molecular species identified in both rat plasma and rat liver by this off-line two-dimensional method is approximately twice of that by one-dimensional RPLC-MS/MS employing a C30 column. This off-line two-dimensional mixed-mode LC-RPLC-MS/MS method is a promising technique for comprehensive lipid profiling in complex biological matrices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 150
页数:11
相关论文
共 50 条
  • [31] Analysis of racemization products of synthetic heptapeptide by reversed phase high performance liquid chromatography/mass spectrometry
    Qi Wei
    Jia Chenxi
    He Zhimin
    Qiao Bin
    Zhang Yanying
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (09) : 1244 - 1248
  • [32] Quality control analysis of plant growth regulator forchlorfenuron by reversed phase high performance liquid chromatography and liquid chromatography-mass spectrometry
    Lian, HZ
    Li, DN
    Zhu, W
    ASIAN JOURNAL OF CHEMISTRY, 2005, 17 (03) : 1617 - 1624
  • [33] Rapid high performance liquid chromatography-high resolution mass spectrometry methodology for multiple prenol lipids analysis in zebrafish embryos
    Martano, Chiara
    Mugoni, Vera
    Dal Bello, Federica
    Santoro, Massimo M.
    Medana, Claudio
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1412 : 59 - 66
  • [34] Countercurrent chromatography separation of saponins by skeleton type from Ampelozizyphus amazonicus for off-line ultra-high-performance liquid chromatography/high resolution accurate mass spectrometry analysis and characterisation
    Figueiredo, Fabiana de Souza
    Celan, Rita
    Silva, Danila de Sousa
    Costa, Fernanda das Neves
    Hewitson, Peter
    Ignatova, Svetlana
    Piccinelli, Anna Lisa
    Rastrelli, Luca
    Leitao, Suzana Guimaraes
    Leitao, Gilda Guimaraes
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1481 : 92 - 100
  • [35] Comprehensive profiling of Sanguisorba officinalis using offline two-dimensional mixed-mode liquid chromatography x reversed-phase liquid chromatography, tandem high-resolution mass spectrometry, and molecular network
    Dai, Yubei
    Zhang, Kailian
    Xiong, Ling
    Wang, Long
    Guo, Zhimou
    Yang, Jing
    Wu, Anguo
    Wu, Jianming
    Zeng, Jing
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (10) : 1727 - 1736
  • [36] Metabolic study of methylstenbolone in horses using liquid chromatography-high resolution mass spectrometry and gas chromatography-mass spectrometry
    Choi, Timmy L. S.
    Wong, Jenny K. Y.
    Kwok, Wai Him
    Curl, Peter
    Mechie, Stewart
    Wan, Terence S. M.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1546 : 106 - 118
  • [37] MECHANIZED OFF-LINE COMBINATION OF MICROBORE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND LASER MASS-SPECTROMETRY
    HUBER, JFK
    DZIDO, T
    HERESCH, F
    JOURNAL OF CHROMATOGRAPHY, 1983, 271 (01): : 27 - 33
  • [38] Application of mixed-mode ultra high performance liquid chromatography to forensic drug analysis
    Clyde, Cassandra
    Blake, Samantha
    Obrien, Stacey
    Igwilo, Ihuoma
    Lurie, Ira S.
    ANALYTICAL METHODS, 2015, 7 (23) : 9763 - 9772
  • [39] A data processing pipeline for petroleomics based on liquid chromatography-high resolution mass spectrometry
    Xia, Yueyi
    Wang, Xiaoxiao
    Ma, Chenfei
    Wang, Xinxin
    Zhao, Chunxia
    Zhao, Xinjie
    Zhang, Zhanquan
    Yu, Yinglong
    Lin, Xiaohui
    Lu, Xin
    Xu, Guowang
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1673
  • [40] Screening and quantification of pesticide residues in ciders by liquid chromatography-high resolution mass spectrometry
    Zustakova, Veronika
    Dusek, Martin
    Jandovska, Vladimira
    Olsovska, Jana
    CZECH JOURNAL OF FOOD SCIENCES, 2023, 41 (01) : 29 - 35