Off-line mixed-mode liquid chromatography coupled with reversed phase high performance liquid chromatography-high resolution mass spectrometry to improve coverage in lipidomics analysis

被引:37
|
作者
Narvaez-Rivas, Monica [1 ]
Ngoc Vu [2 ]
Chen, Guan-Yuan [1 ]
Zhang, Qibin [1 ,2 ]
机构
[1] Univ North Carolina Greensboro, Ctr Translat Biomed Res, North Carolina Res Campus,500 Laureate Way, Kannapolis, NC 28081 USA
[2] Univ North Carolina Greensboro, Dept Chem & Biochem, Greensboro, NC 27412 USA
基金
美国国家卫生研究院;
关键词
Rat plasma lipidome; Rat liver lipidome; Off-line two-dimensional liquid chromatography; Untargeted lipidomics; Monolithic column; Accucore C30 column; LIGHT-SCATTERING DETECTOR; MULTIVARIATE DATA-ANALYSIS; LC-QTOF-MS; HUMAN PLASMA; SEPARATION; IDENTIFICATION; PHOSPHOLIPIDS; TISSUES; LIPIDS; QUANTIFICATION;
D O I
10.1016/j.aca.2016.12.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The confident identification and in-depth profiling of molecular lipid species remain to be a challenge in lipidomics analysis. In this work, an off-line two-dimensional mixed-mode and reversed-phase liquid chromatography (RPLC) method combined with high-field quadrupole orbitrap mass spectrometer (Q Exactive HF) was developed to profile lipids from complex biological samples. In the first dimension, 22 different lipid classes were separated on a monolithic silica column with elution order from neutral to polar lipids. A total of 13 fractions were collected and run on a RPLC 00 column in the second dimension for further separation of the lipid molecular species based on their hydrophobicity, with the elution order being determined by both the length and degree of unsaturation in the fatty-acyl chain. The method was applied to analyze lipids extracted from rat plasma and rat liver. Fatty acid methyl ester analysis by gas chromatography-mass spectrometry was used to identify the fatty acyls from total lipid extracts, which provided a more confident identification of the lipid species present in these samples. More than 800 lipids were identified in each sample and their molecular structures were confidentially confirmed using tandem mass spectrometry (MS/MS). The number of lipid molecular species identified in both rat plasma and rat liver by this off-line two-dimensional method is approximately twice of that by one-dimensional RPLC-MS/MS employing a C30 column. This off-line two-dimensional mixed-mode LC-RPLC-MS/MS method is a promising technique for comprehensive lipid profiling in complex biological matrices. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 150
页数:11
相关论文
共 50 条
  • [31] Determination of ketamine and norketamine in hair by micropulverized extraction and liquid chromatography-high resolution mass spectrometry
    Favretto, Donata
    Vogliardi, Susanna
    Stocchero, Giulia
    Nalesso, Alessandro
    Tucci, Marianna
    Terranova, Claudio
    Ferrara, Santo Davide
    FORENSIC SCIENCE INTERNATIONAL, 2013, 226 (1-3) : 88 - 93
  • [32] Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry
    Matysik, Silke
    Liebisch, Gerhard
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1526 : 112 - 118
  • [33] Pressurised liquid extraction and liquid chromatography-high resolution mass spectrometry to determine high-intensity sweeteners in fish samples
    Nunez, Mireia
    Borrull, Francesc
    Pocurull, Eva
    Fontanals, Nuria
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1479 : 32 - 39
  • [34] Speciation Analysis of Arsenics in Commercial Hijiki by High Performance Liquid Chromatography-tandem-mass Spectrometry and High Performance Liquid Chromatography-inductively Coupled Plasma Mass Spectrometry
    Shimoda, Yasuyo
    Suzuki, Yoshihiro
    Endo, Yoko
    Kato, Koichi
    Tachikawa, Mariko
    Endo, Ginji
    Yamanaka, Kenzo
    JOURNAL OF HEALTH SCIENCE, 2010, 56 (01) : 47 - 56
  • [35] Determination of four amide synthetic cannabinoid isomers by ultra-high performance liquid chromatography-high resolution mass spectrometry
    Tang Ruiyang
    Wang Jifen
    Xiao Tingyue
    Qin Shiyang
    Jie Zhaowei
    Zhang Aolin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2024, 42 (01) : 84 - 91
  • [36] Off-Line Two-Dimensional liquid Chromatography with Maximized Sample Loading to Reversed-Phase Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry for Shotgun Proteome Analysis
    Wang, Nan
    Xie, Chuanhui
    Young, J. Bryce
    Li, Liang
    ANALYTICAL CHEMISTRY, 2009, 81 (03) : 1049 - 1060
  • [37] Method of extraction and proteome profiling of mycobacteria using liquid chromatography-high resolution mass spectrometry
    Bajaj, Amol
    Saraswat, Suraj
    Freeke, Joanna
    Barker, Adam
    SN APPLIED SCIENCES, 2020, 2 (11):
  • [38] Comprehensive analysis of resveratrol metabolites in rats using ultra high performance liquid chromatography coupled with high resolution mass spectrometry
    Liu, Zihan
    Wang, Shaoping
    Dong, Fan
    Lin, Ying
    Li, Haoran
    Shi, Lei
    Wang, Zhibin
    Zhang, Jiayu
    ARABIAN JOURNAL OF CHEMISTRY, 2020, 13 (09) : 7055 - 7065
  • [39] Exploiting the formation of adducts in mobile phases with ammonium fluoride for the enhancement of annotation in liquid chromatography-high resolution mass spectrometry based lipidomics
    Gonzalez-Riano, Carolina
    Gradillas, Ana
    Barbas, Coral
    JOURNAL OF CHROMATOGRAPHY OPEN, 2021, 1
  • [40] Quantitation of carbohydrate monomers and dimers by liquid chromatography coupled with high-resolution mass spectrometry
    Barzen-Hanson, Krista A.
    Wilkes, Rebecca A.
    Aristilde, Ludmilla
    CARBOHYDRATE RESEARCH, 2018, 468 : 30 - 35