Effect of Osmotherapy on Optic Nerve Sheath Diameter in Patients with Increased Intracranial Pressure

被引:63
|
作者
Launey, Yoann [1 ,2 ,3 ]
Nesseler, Nicolas [1 ,2 ,3 ]
Le Maguet, Pascale [1 ]
Malledant, Yannick [1 ,2 ,3 ]
Seguin, Philippe [1 ,2 ,3 ]
机构
[1] Hop Pontchaillou, CHU Rennes, Dept Anesthesie Reanimat, F-35033 Rennes, France
[2] INSERM, U991, Rennes, France
[3] Univ Rennes 1, Rennes, France
关键词
intracranial hypertension; adult brain injury; optic nerve sheath diameter; osmotherapy; TRANSORBITAL SONOGRAPHIC EVALUATION; OCULAR SONOGRAPHY; ULTRASOUND; HYPERTENSION; ULTRASONOGRAPHY; FUNDAMENTALS; MANAGEMENT; EXPANSION; ACCURACY;
D O I
10.1089/neu.2012.2829
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The measurement of ocular nerve sheath diameter (ONSD) via ocular ultrasound scanning is a recent non-invasive method for intracranial pressure (ICP) assessment. Few clinical studies have assessed ONSD variations during osmotherapy for the treatment of sustained increased ICP episodes. The aim of our study was to determine the rate of ONSD variation after mannitol administration for increased ICP episodes. We consecutively included in a prospective, observational study, the patients who had severe acute brain injury and monitored with an invasive ICP monitor. For each episode of sustained elevated ICP, the ONSD was measured in the right and left eye with a 7.5-MHz echography probe, and the mean value was reported. Simultaneously, ICP and cerebral perfusion pressure (CPP) were recorded. All measurements were performed just before and 20 minutes following a 20% mannitol infusion. Data were expressed as medians and interquartile ranges. Thirteen patients were included and analysed (traumatic brain injury, n=10; subarachnoid haemorrhage, n=3). The median value of the mannitol dose infused was 0.54 g/kg (0.49-0.80 g/kg). In all cases, the ONSD was greater than 5.8 mm before osmotherapy. The ONSD significantly decreased after mannitol infusion from 6.3 (6.1-6.7) to 5. mm (5.5-6.3) (p=0.0007). Concomitantly, the intracranial pressure decreased from 35 (32-41) to 25 (22-29) mmHg (p=0.001) and the CPP increased from 47 (50-60) to 66 (59-69) mmHg (p=0.003). The variations of ONSD appear to be an interesting parameter to evaluate the efficacy of osmotherapy for elevated ICP episodes in patients with acute brain injury.
引用
收藏
页码:984 / 988
页数:5
相关论文
共 50 条
  • [41] Optic nerve sheath diameter on computed tomography is correlated with simultaneously measured intracranial pressure in patients with severe traumatic brain injury
    Sekhon, Mypinder S.
    Griesdale, Donald E.
    Robba, Chiara
    McGlashan, Nick
    Needham, Edward
    Walland, Katherine
    Shook, Alyssa C.
    Smielewski, Peter
    Czosnyka, Marek
    Gupta, Arun K.
    Menon, David K.
    INTENSIVE CARE MEDICINE, 2014, 40 (09) : 1267 - 1274
  • [42] Ultrasonic Assessment of Optic Nerve Sheath to Detect Increased Intracranial Pressure
    Hanafi, Mohammad Ghasem
    Verki, Mohammadreza Maleki
    Parei, Sima Norouzi
    JOURNAL OF MEDICAL ULTRASOUND, 2019, 27 (02) : 69 - 74
  • [43] Optic nerve sheath diameter measurement as a risk marker for significant intracranial hypertension
    Geeraerts, Thomas
    Dubost, Clement
    BIOMARKERS IN MEDICINE, 2009, 3 (02) : 129 - 137
  • [44] Optic nerve sheath diameter threshold by ocular ultrasonography for detection of increased intracranial pressure in Korean adult patients with brain lesions
    Lee, Si Un
    Jeon, Jin Pyeong
    Lee, Hannah
    Han, Jung Ho
    Seo, Mingu
    Byoun, Hyoung Soo
    Cho, Won-Sang
    Ryu, Ho Geol
    Kang, Hyun-Seung
    Kim, Jeong Eun
    Kim, Heung Cheol
    Jang, Kyung-Sool
    MEDICINE, 2016, 95 (41)
  • [45] Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis
    Montorfano, Lisandro
    Yu, Qian
    Bordes, Stephen J.
    Sivanushanthan, Shankarapryan
    Rosenthal, Raul J.
    Montorfano, Miguel
    ULTRASOUND JOURNAL, 2021, 13 (01)
  • [46] Sonographic Optic Nerve Sheath Diameter as an Estimate of Intracranial Pressure in Adult Trauma
    Strumwasser, Aaron
    Kwan, Rita O.
    Yeung, Louise
    Miraflor, Emily
    Ereso, Alex
    Castro-Moure, Frederico
    Patel, Atul
    Sadjadi, Javid
    Victorino, Gregory P.
    JOURNAL OF SURGICAL RESEARCH, 2011, 170 (02) : 265 - 271
  • [47] TRANSCRANIAL ULTRASOUND TO DETECT ELEVATED INTRACRANIAL PRESSURE: COMPARISON OF SEPTUM PELLUCIDUM UNDULATIONS AND OPTIC NERVE SHEATH DIAMETER
    Bolesch, Susanne
    von Wegner, Frederic
    Senft, Christian
    Lorenz, Matthias W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) : 1233 - 1240
  • [48] Correlating optic nerve sheath diameter with opening intracranial pressure in pediatric traumatic brain injury
    Young, Adam M. H.
    Guilfoyle, Mathew R.
    Donnelly, Joseph
    Scoffings, Daniel
    Fernandes, Helen
    Garnett, Mathew
    Agrawal, Shruti
    Hutchinson, Peter J.
    PEDIATRIC RESEARCH, 2017, 81 (03) : 443 - 447
  • [49] Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
    Julie Dubourg
    Etienne Javouhey
    Thomas Geeraerts
    Mahmoud Messerer
    Behrouz Kassai
    Intensive Care Medicine, 2011, 37 : 1059 - 1068
  • [50] Evaluation of Increased Intracranial Pressure with the Optic Nerve Sheath Diameter by Ultrasound in Epiduroscopic Neural Laser Discectomy Procedures
    Beyaz, Serbulent Gokhan
    Kaya, Burak
    Ulgen, Ali Metin
    Sahin, Fatih
    Kocayigit, Havva
    Issi, Zeynep Tuncer
    PAIN PHYSICIAN, 2021, 24 (05) : E595 - E600