Effect of Osmotherapy on Optic Nerve Sheath Diameter in Patients with Increased Intracranial Pressure

被引:63
|
作者
Launey, Yoann [1 ,2 ,3 ]
Nesseler, Nicolas [1 ,2 ,3 ]
Le Maguet, Pascale [1 ]
Malledant, Yannick [1 ,2 ,3 ]
Seguin, Philippe [1 ,2 ,3 ]
机构
[1] Hop Pontchaillou, CHU Rennes, Dept Anesthesie Reanimat, F-35033 Rennes, France
[2] INSERM, U991, Rennes, France
[3] Univ Rennes 1, Rennes, France
关键词
intracranial hypertension; adult brain injury; optic nerve sheath diameter; osmotherapy; TRANSORBITAL SONOGRAPHIC EVALUATION; OCULAR SONOGRAPHY; ULTRASOUND; HYPERTENSION; ULTRASONOGRAPHY; FUNDAMENTALS; MANAGEMENT; EXPANSION; ACCURACY;
D O I
10.1089/neu.2012.2829
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The measurement of ocular nerve sheath diameter (ONSD) via ocular ultrasound scanning is a recent non-invasive method for intracranial pressure (ICP) assessment. Few clinical studies have assessed ONSD variations during osmotherapy for the treatment of sustained increased ICP episodes. The aim of our study was to determine the rate of ONSD variation after mannitol administration for increased ICP episodes. We consecutively included in a prospective, observational study, the patients who had severe acute brain injury and monitored with an invasive ICP monitor. For each episode of sustained elevated ICP, the ONSD was measured in the right and left eye with a 7.5-MHz echography probe, and the mean value was reported. Simultaneously, ICP and cerebral perfusion pressure (CPP) were recorded. All measurements were performed just before and 20 minutes following a 20% mannitol infusion. Data were expressed as medians and interquartile ranges. Thirteen patients were included and analysed (traumatic brain injury, n=10; subarachnoid haemorrhage, n=3). The median value of the mannitol dose infused was 0.54 g/kg (0.49-0.80 g/kg). In all cases, the ONSD was greater than 5.8 mm before osmotherapy. The ONSD significantly decreased after mannitol infusion from 6.3 (6.1-6.7) to 5. mm (5.5-6.3) (p=0.0007). Concomitantly, the intracranial pressure decreased from 35 (32-41) to 25 (22-29) mmHg (p=0.001) and the CPP increased from 47 (50-60) to 66 (59-69) mmHg (p=0.003). The variations of ONSD appear to be an interesting parameter to evaluate the efficacy of osmotherapy for elevated ICP episodes in patients with acute brain injury.
引用
收藏
页码:984 / 988
页数:5
相关论文
共 50 条
  • [11] Optic nerve sheath diameter and intracranial pressure
    Dubourg, Julie
    Javouhey, Etienne
    Messerer, Mahmoud
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2012, 9 (05) : 570 - 571
  • [12] Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis
    Dubourg, Julie
    Javouhey, Etienne
    Geeraerts, Thomas
    Messerer, Mahmoud
    Kassai, Behrouz
    INTENSIVE CARE MEDICINE, 2011, 37 (07) : 1059 - 1068
  • [13] Bedside Optic Nerve Sheath Diameter Assessment in the Identification of Increased Intracranial Pressure in Suspected Idiopathic Intracranial Hypertension
    Irazuzta, Jose E.
    Brown, Martha E.
    Akhtar, Javed
    PEDIATRIC NEUROLOGY, 2016, 54 : 35 - 38
  • [14] Correlation of optic nerve and optic nerve sheath diameter with intracranial pressure in pigs
    Mija, R.
    Zubak, I
    Schuetz, A.
    Glas, M.
    Fung, C.
    Jakob, S. M.
    Beck, J.
    Z'Graggen, W. J.
    Bloch, Andreas
    PLOS ONE, 2020, 15 (02):
  • [15] Optic Nerve Sheath Diameter is not Related to Intracranial Pressure in Subarachnoid Hemorrhage Patients
    Zoerle, Tommaso
    Caccioppola, Alessio
    D'Angelo, Eleonora
    Carbonara, Marco
    Conte, Giorgio
    Avignone, Sabrina
    Zanier, Elisa R.
    Birg, Tatiana
    Ortolano, Fabrizio
    Triulzi, Fabio
    Stocchetti, Nino
    NEUROCRITICAL CARE, 2020, 33 (02) : 491 - 498
  • [16] Ultrasonographic optic nerve sheath diameter to detect increased intracranial pressure in adults: a meta-analysis
    Kim, Sung-Eun
    Hong, Eun Pyo
    Kim, Heung Cheol
    Lee, Si Un
    Jeon, Jin Pyeong
    ACTA RADIOLOGICA, 2019, 60 (02) : 221 - 229
  • [17] Optic Nerve Sheath Diameter Assessment in Patients with Intracranial Pressure Monitoring
    Kavi, Tapan
    Gupta, Anuj
    Hunter, Krystal
    Schreiber, Craig
    Shaikh, Hamza
    Turtz, Alan R.
    CUREUS, 2018, 10 (11):
  • [18] Is increased intracranial pressure a reason for headache in COVID-19 patients? Evaluation with optic nerve sheath diameter
    Simsek, Zuhal Ozer
    Guzeldag, Seda
    Ertas, Sule Ketenci
    Dincaslan, Yasemin
    NEUROLOGY ASIA, 2022, 27 (02) : 379 - 383
  • [19] Point-of-care ultrasound of optic nerve sheath diameter to detect intracranial pressure in neurocritically ill children - A narrative review
    Lin, Jainn-Jim
    Chen, Aaron E.
    Lin, Elaina E.
    Hsia, Shao-Hsuan
    Chiang, Ming-Chou
    Lin, Kuang-Lin
    BIOMEDICAL JOURNAL, 2020, 43 (03) : 231 - 239
  • [20] Bedside Sonographic Measurement of Optic Nerve Sheath Diameter as a Predictor of Increased Intracranial Pressure in Children
    Le, Audrey
    Hoehn, Mary Ellen
    Smith, Mary E.
    Spentzas, Thomas
    Schlappy, David
    Pershad, Jay
    ANNALS OF EMERGENCY MEDICINE, 2009, 53 (06) : 785 - 791