An Experimental Biomechanical Study on Artificial Atlantoodontoid Joint Replacement in Dogs

被引:1
作者
Zang, Quanjin [1 ]
Liu, Yanming [1 ]
Wang, Dengfeng [1 ]
Li, Haopeng [1 ]
Yang, Pinglin [1 ]
Wang, Dong [1 ]
He, Xijing [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Orthopaed, Affiliated Hosp 2, Xian 710000, Peoples R China
来源
CLINICAL SPINE SURGERY | 2017年 / 30卷 / 01期
关键词
artificial atlantoodontoid joint; atlantoaxial instability; range of motion; neutral zone; stiffness; biomechanics; UPPER CERVICAL-SPINE; MECHANICAL-PROPERTIES; FIXATION TECHNIQUES; STABILIZATION; STRENGTH; MODEL; BONE;
D O I
10.1097/BSD.0000000000000255
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: This study tested the biomechanics of artificial atlantoodontoid joint replacement (AAOJR) in a dog model. Dogs were divided into the artificial AAOJR group (n = 10), the decompression group (n = 10), and the healthy control group (n = 10) using a random number table. Objective: To evaluate whether the use of AAOJR for repair of atlantoaxial instability retains rotation and restores stability. Summary of Background data: Atlantoaxial instability is characterized by excessive movement or laxity at the junction between the atlas (C1) and axis (C2). Pure decompression can lead to considerable loss of head and neck rotation and postoperative impairment. A series of biomechanical tests on cadavers found that the artificial AAOJR might rebuild the stability and retain the rotation function. Methods: We designed the AAOJ based on the radiologic and anatomic data of the dog atlas and axis, and established an animal model by resecting the odontoid and implanting the AAOJ into dogs. The biomechanical experiments measured the range of motion (ROM), neutral zone (NZ), and stiffness of flexion, extension, lateral bending, and axial rotation in the intact state, the decompressed state, after AAOJR, and after a fatigue test. Results: Compared with the intact state, after decompression operation, ROM and NZ in all directions, and stiffness during flexion were increased, and stiffness in all other directions was decreased. Compared with the after decompression state, AAOJR before and after the fatigue test resulted in decreased ROM in all directions (all P < 0.05), decreased NZ during flexion/extension and lateral bending (all P < 0.05), an increased NZ during axial rotation (both P < 0.05), and increased stiffness in all directions (all P < 0.05). Conclusions: These results indicate that AAOJR could reconstruct the vertebral stability of the C1-C2 segment and retain some axial rotation function.
引用
收藏
页码:E1 / E6
页数:6
相关论文
共 21 条
[1]   BONE-GRAFT TRANSLATION OF 4 UPPER CERVICAL-SPINE FIXATION TECHNIQUES IN A CADAVERIC MODEL [J].
CRISCO, JJ ;
PANJABI, MM ;
ODA, T ;
GROB, D ;
DVORAK, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (06) :835-846
[2]   BIOMECHANICAL EFFECTS OF TRANSORAL ODONTOIDECTOMY [J].
DICKMAN, CA ;
CRAWFORD, NR ;
BRANTLEY, AGU ;
SONNTAG, VKH .
NEUROSURGERY, 1995, 36 (06) :1146-1152
[3]   MAGNETIC-RESONANCE-IMAGING OF THE TRANSVERSE ATLANTAL LIGAMENT FOR THE EVALUATION OF ATLANTOAXIAL INSTABILITY [J].
DICKMAN, CA ;
MAMOURIAN, A ;
SONNTAG, VKH ;
DRAYER, BP .
JOURNAL OF NEUROSURGERY, 1991, 75 (02) :221-227
[4]   Quantitative anatomy of the lateral mass of the atlas [J].
Dong, Y ;
Hong, MX ;
Li, JY ;
Lin, MY .
SPINE, 2003, 28 (09) :860-863
[5]   Physiological axial compressive preloads increase motion segment stiffness, linearity and hysteresis in all six degrees of freedom for small displacements about the neutral posture [J].
Gardner-Morse, MG ;
Stokes, IA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (03) :547-552
[6]   BIOMECHANICAL EVALUATION OF 4 DIFFERENT POSTERIOR ATLANTOAXIAL FIXATION TECHNIQUES [J].
GROB, D ;
CRISCO, JJ ;
PANJABI, MM ;
WANG, P ;
DVORAK, J .
SPINE, 1992, 17 (05) :480-490
[7]  
Hu Yong, 2007, Chin J Traumatol, V10, P138
[8]   A novel technique of intra-spinous process injection of PMMA to augment the strength of an inter-spinous process device such as the X STOP [J].
Idler, Cary ;
Zucherman, James F. ;
Yerby, Scott ;
Hsu, Ken Y. ;
Hannibal, Matthew ;
Kondrashov, Dimitriy .
SPINE, 2008, 33 (04) :452-456
[9]   Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results [J].
Koller, Heiko ;
Kammermeier, Volker ;
Ulbricht, Dietmar ;
Assuncao, Allan ;
Karolus, Stefan ;
van den Berg, Boris ;
Holz, Ulrich .
EUROPEAN SPINE JOURNAL, 2006, 15 (09) :1326-1338
[10]   Artificial atlanto-odontoid joint replacement through a transoral approach [J].
Lu, Bin ;
He, Xi Jing ;
Zhao, Chen Guang ;
Li, Hao Peng ;
Wang, Dong .
EUROPEAN SPINE JOURNAL, 2009, 18 (01) :109-117