Sonographic Measurement of Cross-Sectional Area of the Median Nerve in the Diagnosis of Carpal Tunnel Syndrome: Correlation with Nerve Conduction Studies

被引:115
|
作者
Moran, Luz [1 ]
Perez, Maria [1 ]
Esteban, Angel [2 ]
Bellon, Jose [3 ]
Arranz, Beatriz [2 ]
del Cerro, Miguel [4 ]
机构
[1] Hosp Univ Gregorio Maranon, Dept Radiol, Madrid, Spain
[2] Hosp Gregorio Maranon, Dept Neurophysiol, Madrid, Spain
[3] Hosp Gregorio Maranon, Dept Stat, Madrid, Spain
[4] Hosp Gregorio Maranon, Dept Traumatol, Madrid, Spain
关键词
carpal tunnel syndrome; sonography; nerve conduction studies; HIGH-RESOLUTION SONOGRAPHY; ELECTROMYOGRAPHY; ULTRASOUND;
D O I
10.1002/jcu.20551
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. To assess the usefulness of sonographic measurement of the median nerve cross-sectional area (CSA) in the diagnosis of carpal tunnel syndrome (CTS) and grading of its severity using nerve conduction (NC) studies as the standard. Method. The CSA of the median nerve was measured at the tunnel inlet and outlet using the ellipse formula and automatic tracing in 72 hands with suspicion of CTS. Result. The lack of inter-reader reliability led to excluding CSA measurements obtained at the tunnel outlet. Based on the receiver operating characteristic curves, the following cut-off points for the CSA of the median nerve at the tunnel inlet was selected: 9.8 mm and 12.3 mm(2) for the ellipse formula and 11 and 13 mm 2 for automatic tracing.For the ellipse formula, a CSA less than or equal to 9.8 mm(2) excluded CTS whereas a CSA greater than or equal to 12.3 mm(2) was diagnostic of CTS with measurements between 9.8 and 12.3 mm(2) being indeterminate and requiring NC studies. For automatic tracing, the cutoff value of 11 mm 2 was excluded because of the high percentage of false negatives, whereas CSAs greater than or equal to 13 mm(2) were diagnostic of CTS. There were no statistically significant differences in CSA measurements between the various degrees of CTS severity determined by NC studies. Conclusion. Sonographic measurement of median nerve CSA at the tunnel inlet is a good alternative to NC studies as the initial diagnostic test for CTS, but it cannot grade the severity of CTS as well as NC studies. (C) 2009 Wiley Periodicals, Inc. J Clin Ultrasound 37:125-131, 2009; Published online in Wiley InterScience (www.interscience.wiley.com). DOI: 10.1002/jcu.20551
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [11] Correlation of ultrasound cross-sectional area of the median nerve, nerve conduction studies and 2-point discrimination
    Panagopoulos, Georgios N.
    Wu, Tiffany
    Fowler, John R.
    MUSCLE & NERVE, 2019, 59 (02) : 236 - 239
  • [12] Ultrasonographic measurement of median nerve cross-sectional area in idiopathic carpal tunnel syndrome: Diagnostic accuracy
    Nakamichi, KI
    Tachibana, S
    MUSCLE & NERVE, 2002, 26 (06) : 798 - 803
  • [13] Median nerve ultrasound as a screening tool in carpal tunnel syndrome: Correlation of cross-sectional area measures with electrodiagnostic abnormality
    Mhoon, Justin T.
    Juel, Vern C.
    Hobson-Webb, Lisa D.
    MUSCLE & NERVE, 2012, 46 (06) : 871 - 878
  • [14] Measurement of Median Nerve Cross Sectional Area With Ultrasound and MRI in Idiopathic Carpal Tunnel Syndrome Patients
    Duymus, Mahmut
    Ulasli, Alper Murat
    Yilmaz, Omer
    Asal, Nese
    Kacar, Mahmut
    Nacir, Baris
    Erdem, Hatice Rana
    Kosar, Ugur
    JOURNAL OF NEUROLOGICAL SCIENCES-TURKISH, 2013, 30 (01): : 59 - 71
  • [15] Difference and ratio of the cross-sectional area of median nerve at the carpal tunnel and the pronator quadratus muscle in diagnosing carpal tunnel syndrome: a cross-sectional study
    Xu, Cheng
    Zhou, Yang
    He, Zhou
    Liu, Wei
    Zou, Meilin
    Sun, Yanjun
    Qiu, Jinxin
    Ren, Yuting
    Mao, Guomin
    Wang, Yue
    Xi, Qinghua
    Chen, Yuehua
    Zhang, Bin
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (06)
  • [16] Correlation Nerve Conduction Studies with Findings of the Ultrasound of the Median Nerve in Patients with Carpal Tunnel Syndrome
    Torres-Cuenca, Thomas
    Ortiz-Corredor, Fernando
    Diaz-Ruiz, Jorge
    Orozco-Salomon, Diego
    Naranjo-Quevedo, Andres
    CURRENT MEDICAL IMAGING, 2021, 17 (11) : 1340 - 1349
  • [17] Sonographic differences in carpal tunnel syndrome with normal and abnormal nerve conduction studies
    Borire, Adeniyi A.
    Hughes, Andrew R.
    Lueck, Christian J.
    Colebatch, James G.
    Krishnan, Arun V.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 34 : 77 - 80
  • [18] Ultrasonographic Measurement of Median Nerve Cross-Sectional Area in Evaluating Carpal Tunnel Release Outcomes
    Saglam, Gonca
    Turgut, Mehmet Cenk
    Semis, Halil Sezgin
    Toy, Serdar
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (10): : 1060.e1 - 1060.e8
  • [19] Diagnostic Value of Cross-Sectional Area of Median Nerve in Grading Severity of Carpal Tunnel Syndrome
    Mohammadi, Afshin
    Afshar, Ahmadreza
    Etemadi, Ardeshir
    Masoudi, Sima
    Baghizadeh, Atieh
    ARCHIVES OF IRANIAN MEDICINE, 2010, 13 (06) : 516 - 521
  • [20] Ratio and difference of the cross-sectional area of median nerve to ulnar nerve in diagnosing carpal tunnel syndrome: a case control study
    Chang, Yi-Wei
    Hsieh, Tsung-Cheng
    Tzeng, I-Shiang
    Chiu, Valeria
    Huang, Pei-Jung
    Horng, Yi-Shiung
    BMC MEDICAL IMAGING, 2019, 19