Limitations of coronary computed tomographic angiography for delineating the lumen and vessel contours of coronary arteries in patients with stable angina

被引:14
作者
Kim, Choongki [1 ]
Hong, Sung-Jin [1 ]
Shin, Dong-Ho [1 ,2 ]
Kim, Jung-Sun [1 ,2 ]
Kim, Byeong-Keuk [1 ,2 ]
Ko, Young-Guk [1 ,2 ]
Choi, Donghoon [1 ,2 ]
Jang, Yangsoo [1 ,2 ,3 ]
Hong, Myeong-Ki [1 ,2 ,3 ]
机构
[1] Yonsei Univ Hlth Syst, Severance Cardiovasc Hosp, Seoul, South Korea
[2] Yonsei Univ, Coll Med, Cardiovasc Res Inst, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
关键词
coronary artery disease; coronary computed tomographic angiography; intravascular ultrasound; FRACTIONAL FLOW RESERVE; INTRAVASCULAR ULTRASOUND; ATHEROSCLEROTIC PLAQUE; VIRTUAL HISTOLOGY; CT ANGIOGRAPHY; DIAGNOSTIC-ACCURACY; AMERICAN-COLLEGE; TASK-FORCE; QUANTIFICATION; STENOSIS;
D O I
10.1093/ehjci/jev100
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We sought to evaluate whether coronary computed tomographic angiography (CCTA) could accurately and reproducibly delineate the lumen and vessel contours of coronary arteries. Methods and results One hundred coronary stenotic lesions representing 91 patients with stable angina who received both CCTA and intravascular ultrasound (IVUS) were analysed. Three segments with minimal lumen cross-sectional area (CSA), proximal reference, and distal reference on IVUS images were selected for each lesion. Five observers measured lumen and vessel CSAs at three matching segments on CCTA images. These CSAs were compared with the IVUS-measured CSAs as a reference standard. All five observers underestimated lumen CSA at the three selected segments by CCTA. The minimal lumen CSA assessed by CCTA exhibited very weak correlations with those obtained by IVUS (r = 0.23, 0.24, 0.15, 0.25, and 0.28, respectively). In contrast to the lumen CSA, the vessel CSA at the three segments was overestimated by all observers when assessed by CCTA. At the segment with minimal lumen CSA, the vessel CSA obtained by CCTA showed weak correlations with those assessed by IVUS (r = 0.43, 0.33, 0.44, 0.37, and 0.42, respectively). Moreover, intra-class correlation coefficients ranged from 0.44 to 0.73 among the five observers for lumen or vessel CSA measurements by CCTA at the segment with minimal lumen CSA. Conclusion CCTA has potential limitations in the accurate delineation of lumen and vessel contours in patients with angina, as there was a high level of discordance with the IVUS-measured lumen and vessel CSAs and high inter-observer variability.
引用
收藏
页码:1358 / 1365
页数:8
相关论文
共 21 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   Accuracy of dual-source CT in the characterisation of non-calcified plaque: use of a colour-coded analysis compared with virtual histology intravascular ultrasound [J].
Brodoefel, H. ;
Burgstahler, C. ;
Heuschmid, M. ;
Reimann, A. ;
Khosa, F. ;
Kopp, A. ;
Schroeder, S. ;
Claussen, C. D. ;
Clouse, M. E. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (982) :805-812
[3]   Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[4]   Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography [J].
Chun, Eun Ju ;
Lee, Whal ;
Choi, Young Hoon ;
Koo, Bon-Kwon ;
Choi, Sang Il ;
Jae, Hwan Jun ;
Kim, Hyo-Cheol ;
So, Young Ho ;
Chung, Jin Wook ;
Park, Jae Hyung .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (01) :86-92
[5]   Automatic quantification and characterization of coronary atherosclerosis with computed tomography coronary angiography: cross-correlation with intravascular ultrasound virtual histology [J].
de Graaf, Michiel A. ;
Broersen, Alexander ;
Kitslaar, Pieter H. ;
Roos, Cornelis J. ;
Dijkstra, Jouke ;
Lelieveldt, Boudewijn P. F. ;
Jukema, J. Wouter ;
Schalij, Martin J. ;
Delgado, Victoria ;
Bax, Jeroen J. ;
Reiber, Johan H. C. ;
Scholte, Arthur J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) :1177-1190
[6]   Effects of sublingual nitroglycerin on coronary lumen diameter and number of visualized septal branches on 64-MDCT angiography [J].
Decramer, Isabel ;
Vanhoenacker, Piet K. ;
Sarno, Giovanna ;
Van Hoe, Lieven ;
Bladt, Olivier ;
Wijns, William ;
Parizel, Paul M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) :219-225
[7]   Coronary CT angiography versus intravascular ultrasound for estimation of coronary stenosis and atherosclerotic plaque burden: A meta-analysis [J].
Fischer, Collin ;
Hulten, Edward ;
Belur, Pallavi ;
Smith, Ryan ;
Voros, Szilard ;
Villines, Todd C. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (04) :256-266
[8]   Quantification and Characterization of Obstructive Coronary Plaques Using 64-Slice Computed Tomography: A Comparison With Intravascular Ultrasound [J].
Hur, Jin ;
Kim, Young Jin ;
Lee, Hye-Jeong ;
Nam, Ji Eun ;
Choe, Kyu Ok ;
Seo, Jae Seung ;
Choi, Dong-Hoon ;
Kim, Jung-Sun ;
Choi, Byoung Wook .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) :186-192
[9]   Impact of Coronary Artery Calcium Characteristics on Accuracy of CT Angiography [J].
Kruk, Mariusz ;
Noll, Dariusz ;
Achenbach, Stefan ;
Mintz, Gary S. ;
Pregowski, Jerzy ;
Kaczmarska, Edyta ;
Kryczka, Karolina ;
Pracon, Radoslow ;
Dzielinska, Zofia ;
Sleszycka, Justyna ;
Witkowski, Adam ;
Demkow, Marcin ;
Ruzyllo, Witold ;
Kepka, Cezary .
JACC-CARDIOVASCULAR IMAGING, 2014, 7 (01) :49-58
[10]   Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system - A comparative study using intravascular ultrasound [J].
Leber, AW ;
Becker, A ;
Knez, A ;
von Ziegler, F ;
Sirol, M ;
Nikolaou, K ;
Ohnesorge, B ;
Fayad, ZA ;
Becker, CR ;
Reiser, M ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (03) :672-677