Early Corrosion Detection in Prestressed Concrete Girders Using Acoustic Emission

被引:70
作者
ElBatanouny, Mohamed K. [1 ]
Mangual, Jese [1 ]
Ziehl, Paul H. [1 ]
Matta, Fabio [1 ]
机构
[1] Univ S Carolina, Columbia, SC 29208 USA
关键词
Prestressed concrete; Acoustic emission; Residual capacity; Nondestructive evaluation; Accelerated corrosion; REINFORCED-CONCRETE; CAPACITY; BEHAVIOR; STRANDS; DAMAGE;
D O I
10.1061/(ASCE)MT.1943-5533.0000845
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Long-term corrosion tests were performed on prestressed T-girders measuring 4.98m (16ft, 4in.). The test program was composed of four specimens, including one control. The specimens were subjected to wet/dry cycles using 3% NaCl solution to accelerate corrosion. Two of the specimens were precracked prior to conditioning to examine the effect of crack presence and/or width. The specimens were continuously monitored using acoustic emission (AE). Half-cell potential (HCP) measurements and linear polarization resistance (LPR) were performed daily to serve as a benchmark for corrosion detection. Acoustic emission can detect the onset of corrosion comparable in time to conventional electrochemical methods. Furthermore, AE intensity analysis has the ability to distinguish between different levels of corrosion. The specimens were load-tested to measure the residual capacity, which can give an indication of AE's ability to detect corrosion damage before it affects the strength of prestressed structures.
引用
收藏
页码:504 / 511
页数:8
相关论文
共 27 条
[1]   QUANTITATIVE MEASUREMENTS OF CORROSION RATE OF REINFORCING STEELS EMBEDDED IN CONCRETE USING POLARIZATION RESISTANCE MEASUREMENTS [J].
ANDRADE, C ;
GONZALEZ, JA .
WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1978, 29 (08) :515-519
[2]  
ANDRADE C, 1990, CORROSION RATES STEE, P29
[3]  
[Anonymous], 2006, E131606 ASTM
[4]  
[Anonymous], 2009, REP CARD AM INFR
[5]  
[Anonymous], 2009, ASTM C876-09
[6]  
ASTM, 1994, G4694 ASMT
[7]  
ASTM, 1997, G5997 ASTM
[8]   Electrochemical behavior of steel-reinforced concrete during accelerated corrosion testing [J].
Austin, SA ;
Lyons, R ;
Ing, MJ .
CORROSION, 2004, 60 (02) :203-212
[9]  
Auyeung Y, 2000, ACI MATER J, V97, P214
[10]   Effect of pitting corrosion on capacity of prestressing wires [J].
Darmawan, M. S. ;
Stewart, M. G. .
MAGAZINE OF CONCRETE RESEARCH, 2007, 59 (02) :131-139