Reducing energy consumption of a steam ejector through experimental optimization of the nozzle geometry

被引:58
作者
Sharifi, Navid [1 ]
Sharifi, Majid [2 ]
机构
[1] Amirkabir Univ Technol, Dept Aerosp Engn, Tehran 158754413, Iran
[2] Drexel Univ, Dept Chem & Biol Engn, Philadelphia, PA 19104 USA
关键词
Energy consumption; Steam ejector; Experimental optimization; CFD simulation; Supersonic nozzle; COMPUTATIONAL FLUID-DYNAMICS; THERMO-COMPRESSOR DESIGN; NUMERICAL ASSESSMENT; REFRIGERATION; PERFORMANCE; VALIDATION;
D O I
10.1016/j.energy.2014.01.055
中图分类号
O414.1 [热力学];
学科分类号
摘要
Steam ejectors use pressurized vapor as the motive flow for running in steam cycles. The major parameter that affects the thermal energy consumption is the pressure of motive flow used in this device. In the current study, a malfunctioning experimental ejector is studied numerically to reveal the source of low evacuation rate from a suction chamber. This ejector was designed to operate under a motive pressure of 6 bar. However, the required vacuum in the suction vessel was not attained unless the pressure of motive steam was increased to 8 bar. The fastest and the most inexpensive way of improving the device performance was considered as replacing just the primary nozzle, with no further changes in ejector's body because, the ejector was connected to other unit facilities and hence the ejector replacement was very costly. The optimization procedure was performed through using numerical CFD (Computational Fluid Dynamics) simulations. The shape of internal supersonic nozzle was changed in many CFD analyses and the most optimized nozzle was selected for manufacturing. After installing the designed nozzle, an improved entrainment capability under the nominal pressure of 6 bar was observed and the desired vacuum level was attained. (c) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:860 / 867
页数:8
相关论文
共 22 条
[1]   Numerical assessment of ejector operation for refrigeration applications based on CFD [J].
Bartosiewicz, Y ;
Aidoun, Z ;
Mercadier, Y .
APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) :604-612
[2]   Experimental study on R-134a refrigeration system using a two-phase ejector as an expansion device [J].
Chaiwongsa, Praitoon ;
Wongwises, Somchai .
APPLIED THERMAL ENGINEERING, 2008, 28 (5-6) :467-477
[3]  
Dayem AMA, 2006, ENERGY, V31, P2710, DOI 10.1016/j.energy.2006.01.008
[4]  
Desevaux P, 2002, INT J TURBO JET ENG, V19, P71
[5]  
*FLUENT INC, FLUENT 6 3 US GUID
[6]   CFD investigation on the flow structure inside thermo vapor compressor [J].
Ji, MyoungKuk ;
Utomo, Tony ;
Woo, JuSik ;
Lee, YongHun ;
Jeong, HyoMin ;
Chung, HanShik .
ENERGY, 2010, 35 (06) :2694-2702
[7]   Experience of modification of thermo-compressors in multiple effects desalination plants in Assaluyeh in IRAN [J].
Kouhikamali, Ramin ;
Sharifi, Navid .
APPLIED THERMAL ENGINEERING, 2012, 40 :174-180
[8]   Investigation and improvement of ejector refrigeration system using computational fluid dynamics technique [J].
Pianthong, K. ;
SeehanaM, W. ;
Behnia, M. ;
SriveerakUl, T. ;
Aphornratana, S. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (09) :2556-2564
[9]   Energy savings in CO2 (carbon dioxide) capture using ejectors for waste heat upgrading [J].
Reddick, Christopher ;
Sorin, Mikhail ;
Rheault, Fernand .
ENERGY, 2014, 65 :200-208
[10]   Computational fluid dynamics applied to ejector heat pumps [J].
Riffat, SB ;
Gan, G ;
Smith, S .
APPLIED THERMAL ENGINEERING, 1996, 16 (04) :291-297