Flow dynamics control endothelial permeability in a microfluidic vessel bifurcation model

被引:40
|
作者
Akbari, Ehsan [1 ]
Spychalski, Griffin B. [2 ]
Rangharajan, Kaushik K. [1 ]
Prakash, Shaurya [1 ]
Song, Jonathan W. [1 ,3 ]
机构
[1] Ohio State Univ, Dept Mech & Aerosp Engn, Scott Lab, 201 W 19th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[3] Ohio State Univ, Ctr Comprehens Canc, Columbus, OH 43210 USA
关键词
FLUID SHEAR-STRESS; NITRIC-OXIDE; IN-VITRO; BARRIER FUNCTION; MICROVASCULAR PERMEABILITY; VASCULAR-PERMEABILITY; TISSUE ANALOG; RHO-GTPASES; ANGIOGENESIS; TRANSPORT;
D O I
10.1039/c8lc00130h
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Endothelial barrier function is known to be regulated by a number of molecular mechanisms; however, the role of biomechanical signals associated with blood flow is comparatively less explored. Biomimetic microfluidic models comprised of vessel analogues that are lined with endothelial cells (ECs) have been developed to help answer several fundamental questions in endothelial mechanobiology. However, previously described microfluidic models have been primarily restricted to single straight or two parallel vessel analogues, which do not model the bifurcating vessel networks typically present in physiology. Therefore, the effects of hemodynamic stresses that arise due to bifurcating vessel geometries on ECs are not well understood. Here, we introduce and characterize a microfluidic model that mimics both the flow conditions and the endothelial/extracellular matrix (ECM) architecture of bifurcating blood vessels to systematically monitor changes in endothelial permeability mediated by the local flow dynamics at specific locations along the bifurcating vessel structure. We show that bifurcated fluid flow (BFF) that arises only at the base of a vessel bifurcation and is characterized by stagnation pressure of similar to 38 dyn cm(-2) and approximately zero shear stress induces significant decrease in EC permeability compared to the static control condition in a nitric oxide (NO)-dependent manner. Similarly, intravascular laminar shear stress (LSS) (3 dyn cm(-2)) oriented tangential to ECs located downstream of the vessel bifurcation also causes a significant decrease in permeability compared to the static control condition via the NO pathway. In contrast, co-application of transvascular flow (TVF) (similar to 1 mu m s(-1)) with BFF and LSS rescues vessel permeability to the level of the static control condition, which suggests that TVF has a competing role against the stabilization effects of BFF and LSS. These findings introduce BFF at the base of vessel bifurcations as an important regulator of vessel permeability and suggest a mechanism by which local flow dynamics control vascular function in vivo.
引用
收藏
页码:1084 / 1093
页数:10
相关论文
共 50 条
  • [1] Competing Fluid Forces Control Endothelial Sprouting in a 3-D Microfluidic Vessel Bifurcation Model
    Akbari, Ehsan
    Spychalski, Griffin B.
    Rangharajan, Kaushik K.
    Prakash, Shaurya
    Song, Jonathan W.
    MICROMACHINES, 2019, 10 (07)
  • [2] Direct current electric field regulates endothelial permeability under physiologically relevant fluid forces in a microfluidic vessel bifurcation model
    Sundaram, Prashanth Mohana
    Rangharajan, Kaushik K.
    Akbari, Ehsan
    Hadick, Tanner J.
    Song, Jonathan W.
    Prakash, Shaurya
    LAB ON A CHIP, 2021, 21 (02) : 319 - 330
  • [3] Blood flow dynamics in carotid bifurcation and vessel wall changes
    Remuzzi, A
    Piccinelli, M
    Antiga, L
    Caverni, L
    De Monti, M
    BIOMEDICINE & PHARMACOTHERAPY, 2004, 58 (08) : 463 - 463
  • [4] Characterization of vascular permeability using a biomimetic microfluidic blood vessel model
    Thomas, Antony
    Wang, Shunqiang
    Sohrabi, Salman
    Orr, Colin
    He, Ran
    Shi, Wentao
    Liu, Yaling
    BIOMICROFLUIDICS, 2017, 11 (02):
  • [5] Bifurcation Dynamics of a Worm Model with Impulsive Control
    Li, Tao
    Wang, Yuanmei
    Lu, Guangyue
    Xiang, Yalin
    2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL I, 2009, : 779 - 781
  • [6] A microfluidic chip for permeability assays of endothelial monolayer
    Jianbo Shao
    Lei Wu
    Jianzhang Wu
    Yunhuan Zheng
    Hui Zhao
    Xinhui Lou
    Qinghui Jin
    Jianlong Zhao
    Biomedical Microdevices, 2010, 12 : 81 - 88
  • [7] A microfluidic chip for permeability assays of endothelial monolayer
    Shao, Jianbo
    Wu, Lei
    Wu, Jianzhang
    Zheng, Yunhuan
    Zhao, Hui
    Lou, Xinhui
    Jin, Qinghui
    Zhao, Jianlong
    BIOMEDICAL MICRODEVICES, 2010, 12 (01) : 81 - 88
  • [8] The Dynamics and Bifurcation Control of a Singular Biological Economic Model
    Li, Ning
    Sun, Hai-Yi
    Zhang, Qing-Ling
    INTERNATIONAL JOURNAL OF AUTOMATION AND COMPUTING, 2012, 9 (01) : 1 - 7
  • [9] The Dynamics and Bifurcation Control of a Singular Biological Economic Model
    Ning Li1 Hai-Yi Sun2 Qing-Ling Zhang1 1Institute of Systems Science
    International Journal of Automation and Computing, 2012, (01) : 1 - 7
  • [10] Perturbation and bifurcation analysis of a gonorrhoea dynamics model with control
    Omenyi, Louis
    Ezaka, Aloysius
    Adagba, Henry O.
    Oyakhire, Friday
    Elebute, Kafayat
    Offia, Akachukwu
    Ekhator, Monday
    INTERNATIONAL JOURNAL OF ADVANCED AND APPLIED SCIENCES, 2022, 9 (07): : 150 - 158