Open-Switch Fault Diagnosis Algorithm and Tolerant Control Method of the Three-Phase Three-Level NPC Active Rectifier

被引:17
作者
Jung, Jun-Hyung [1 ]
Ku, Hyun-Keun [2 ]
Son, Yung-Deug [3 ]
Kim, Jang-Mok [1 ]
机构
[1] Pusan Natl Univ, Dept Elect & Comp Engn, Busan 46241, South Korea
[2] Korea Elect Power Corp, Converter Stn Construct Team, Naju 58322, Jeollanam Do, South Korea
[3] Korea Univ Technol & Educ, Dept Mech Facil Control Engn, Cheonan 31253, Chungnam, South Korea
关键词
three-level neutral-point clamped (NPC) active rectifier; open-switch fault; fault diagnosis and tolerant control method; space vector modulation (SVM); OPEN-CIRCUIT FAULT; PWM STRATEGY; CONVERTER; INJECTION;
D O I
10.3390/en12132495
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes a fault diagnosis and tolerant control methods for an open-switch fault caused in a three-phase three-level neutral-point-clamped (NPC) pulse-width modulation (PWM) active rectifier. The open-switch fault in the three-level NPC active rectifier causes a distortion in the input phase current and a ripple in the DC-link capacitor voltage. Therefore, proper fault diagnosis and tolerant control methods are required to prevent additional failures and performance degradation in the rectifier system. This paper conducted a detailed analysis of the effect of the single open-switch fault on the NPC PWM active rectifier and proposed a fault diagnosis method utilizing the DC link voltage and the phase angle of the input grid voltage. Furthermore, this paper proposes a fault-tolerant control method to reduce the effect of the open-switch fault by compensating a distorted reference voltage. The effectiveness of the proposed fault diagnosis and tolerant control methods are verified through experimental results.
引用
收藏
页数:17
相关论文
共 29 条
[21]   Space-Vector Pulsewidth Modulation for Three-Level NPC Converter With the Neutral Point Voltage Control [J].
Lewicki, Arkadiusz ;
Krzeminski, Zbigniew ;
Abu-Rub, Haitham .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (11) :5076-5086
[22]   Open-circuit fault diagnosis for a fault-tolerant three-level neutral-point-clamped STATCOM [J].
Li, Haoyang ;
Guo, Yuanbo ;
Xia, Jinhui ;
Li, Ze ;
Zhang, Xiaohua .
IET POWER ELECTRONICS, 2019, 12 (04) :810-816
[23]   Indirect IGBT Over-Current Detection Technique Via Gate Voltage Monitoring and Analysis [J].
Li, Xinchang ;
Xu, Dawei ;
Zhu, Hongyue ;
Cheng, Xinhong ;
Yu, Yuehui ;
Ng, Wai Tung .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (04) :3615-3622
[24]   A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters [J].
Lu, Bin ;
Sharma, Santosh K. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (05) :1770-1777
[25]   Modulation Methods for Neutral-Point-Clamped Wind Power Converter Achieving Loss and Thermal Redistribution Under Low-Voltage Ride-Through [J].
Ma, Ke ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (02) :835-845
[26]   A Carrier-Based PWM Strategy With Zero-Sequence Voltage Injection for a Three-Level Neutral-Point-Clamped Converter [J].
Pou, Josep ;
Zaragoza, Jordi ;
Ceballos, Salvador ;
Saeedifard, Maryam ;
Boroyevich, Dushan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (02) :642-651
[27]   Survey on Reliability of Power Electronic Systems [J].
Song, Yantao ;
Wang, Bingsen .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) :591-604
[28]  
Wu B., 2017, High-power converters and ac drives
[29]   Open-circuit faults diagnosis in back-to-back converters of DF wind turbine [J].
Zhao, Hongshan ;
Cheng, Liangliang .
IET RENEWABLE POWER GENERATION, 2017, 11 (04) :417-424