Heterogeneous time-resolved electrocherniluminoimmunoassay of thyroid stimulating hormone with magnetic beads at oxide-covered aluminum electrode

被引:6
|
作者
Ala-Kleme, Timo [1 ]
机构
[1] Univ Turku, Dept Chem, Turku 20014, Finland
关键词
ELECTROGENERATED CHEMILUMINESCENCE; ELECTROCHEMICAL IMMUNOASSAY; SILICON ELECTRODES; ELECTROCHEMILUMINESCENCE; PROTEIN; ELECTROCHEMILUMINOIMMUNOASSAY; ELECTROLUMINESCENCE; IMMUNOSENSOR; CHELATE; AGENTS;
D O I
10.1016/j.jlumin.2017.02.035
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The heterogeneous immunoassay of thyroid stimulating hormone (TSH) was detected by the time-resolved cathodic electrochemiluminescence immunoassay (tr-CECLIA) method using magnetic beads as a mobile support. The magnetic beads coated with sandwich type TSH immunoassay were captured with a magnet for washing and detection processes. The time-resolved cathodic electrochemiluminescence (tr-CECL) signal of Tb(III) chelate label was generated by cathodic pulse polarization in the aluminum working electrode and platinum counter electrode system. The detection method causes injection of high energy electrons into the aqueous solution near the aluminum electrode and creates rigid simultaneous oxidative and reductive conditions that excitate the Tb(III) chelate used as a label luminophore in the heterogeneous sandwich type immunoassay of TSH in the surface of the magnetic beads. The limit of detection of the method was about 50 mIU L-1. The precision of it was noticed to be good; the coefficient variation percentage was realized to be lower than 10 %. Unfortunately the limit of detection is not good enough for determination of analyte levels of very low concentrations for instance TSH in body fluids. The possible application areas of the method are in highly sophisticated micro or nano fluidic detection and sensor systems where the aspiration level of the analyte detection limit is not very high and the mobility and manageability and the large surface area of the magnetic beads can be utilized efficiently in separating, washing, moving, coating and detecting processes. In the case of tr-CECLIA the presented method makes possible to use multipurpose working electrodes instead of disposable ones. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 10 条
  • [1] EVALUATION OF A TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY FOR SERUM THYROID STIMULATING HORMONE
    PATERSON, N
    BIGGART, EM
    CHAPMAN, RS
    BEASTALL, GH
    ANNALS OF CLINICAL BIOCHEMISTRY, 1985, 22 (NOV) : 606 - 611
  • [2] Hot electron-induced time-resolved electrogenerated luminescence of Tb(III) ions at stationary oxide-covered aluminium electrodes
    Kulmala, S
    Kulmala, A
    Helin, M
    Hyppänen, I
    ANALYTICA CHIMICA ACTA, 1998, 359 (1-2) : 71 - 86
  • [3] Application of Eu(III) nanoparticle labels in time-resolved phosphorescence analysis for detection of thyroid stimulating hormone
    V. G. Pomelova
    N. S. Osin
    T. A. Bychenkova
    D. V. Paramonov
    T. S. Kostryukova
    Russian Journal of Bioorganic Chemistry, 2017, 43 : 377 - 385
  • [4] Application of Eu(III) Nanoparticle Labels in Time-Resolved Phosphorescence Analysis for Detection of Thyroid Stimulating Hormone
    Pomelova, V. G.
    Osin, N. S.
    Bychenkova, T. A.
    Paramonov, D. V.
    Kostryukova, T. S.
    RUSSIAN JOURNAL OF BIOORGANIC CHEMISTRY, 2017, 43 (04) : 377 - 385
  • [5] Sensitive Time-Resolved Fluoroimmunoassay of Human Thyroid-Stimulating Hormone by Using a New Europium Fluorescent Chelate as a Label
    Jingli Yuan
    Guilan Wang
    Hiroko Kimura
    Kazuko Matsumoto
    Analytical Sciences, 1998, 14 : 421 - 423
  • [6] Sensitive time-resolved fluoroimmunoassay of human thyroid-stimulating hormone by using a new europium fluorescent chelate as a label
    Yuan, J
    Wang, G
    Kimura, H
    Matsumoto, K
    ANALYTICAL SCIENCES, 1998, 14 (02) : 421 - 423
  • [7] Sensitive time-resolved fluoroimmunoassay for simultaneous detection of serum thyroid-stimulating hormone and total thyroxin with Eu and Sm as labels
    Wu, FB
    Han, SQ
    Xu, T
    He, YF
    ANALYTICAL BIOCHEMISTRY, 2003, 314 (01) : 87 - 96
  • [8] Application of europium(III) chelates-bonded silica nanoparticle in time-resolved immunofluorometric detection assay for human thyroid stimulating hormone
    Zhou, Yulin
    Xia, Xiaohu
    Xu, Ye
    Ke, Wei
    Yang, Wei
    Li, Qingge
    ANALYTICA CHIMICA ACTA, 2012, 722 : 95 - 99
  • [9] Super-sensitive time-resolved fluoroimmunoassay for thyroid-stimulating hormone utilizing europium(III) nanoparticle labels achieved by protein corona stabilization, short binding time, and serum preprocessing
    Nareoja, Tuomas
    Rosenholm, Jessica M.
    Lamminmaki, Urpo
    Hanninen, Pekka E.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (13) : 3407 - 3416
  • [10] Super-sensitive time-resolved fluoroimmunoassay for thyroid-stimulating hormone utilizing europium(III) nanoparticle labels achieved by protein corona stabilization, short binding time, and serum preprocessing
    Tuomas Näreoja
    Jessica M. Rosenholm
    Urpo Lamminmäki
    Pekka E. Hänninen
    Analytical and Bioanalytical Chemistry, 2017, 409 : 3407 - 3416