Assessment of damages on a RC building after a big fire

被引:14
作者
Ada, Mehmet [1 ]
Sevim, Barb [1 ]
Yuzer, Nabi [1 ]
Ayvaz, Yusuf [1 ]
机构
[1] Yildiz Tech Univ, Dept Civil Engn, Istanbul, Turkey
关键词
beam-column connection damage; elevated temperature; fire damage; RC building; structural element; HIGH-STRENGTH CONCRETE; HIGH-TEMPERATURES; SAFETY DESIGN; PERFORMANCE; EXPOSURE; BOND;
D O I
10.12989/acc.2018.6.2.177
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a case study about the damages on the structural elements of a cast in place reinforced concrete (RC) building after a big fire which was able to be controlled after six hours. The fire broke off at the 2nd basement floor of the building, which has five basements, one ground, and two normal floors. As a result of intensely stocked ignitable materials, it spread out to the all of the upstairs. In visual inspection, most of the typical fire damages were observed (such as spalling, net-like cracks, crumbled plasters, bared or visible reinforcement). Also, failures of the 2nd basement columns were encountered. It has been concluded that the severity failures of the columns at the 2nd basement caused utterly deformation of the building, which is responsible for the massive damages on the beam-column connections. All of the observed damages were categorized related to the types and presented separated regarding the floors. Besides to the visual inspection, the numerical analysis was run to verify the observed damaged on the building for columns, beams, and the connection regions. It is concluded from the study that several parameters such as duration of the fire, level of the temperature influence on the damages to the RC building. Also, it is highlighted by the study that if the damaged building is considered on the overall structural system, it is not able to satisfy the minimum service requirements neither gravity loads nor earthquake conditions.
引用
收藏
页码:177 / 197
页数:21
相关论文
共 40 条
  • [1] [Anonymous], 1997, TECHNICAL REPORT NIS
  • [2] [Anonymous], 1999, ISO 834
  • [3] Predicting the bond between concrete and reinforcing steel at elevated temperatures
    Aslani, Farhad
    Samali, Bijan
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, 2013, 48 (05) : 643 - 660
  • [4] Residual strength and pore structure of high-strength concrete and normal strength concrete after exposure to high temperatures
    Chan, YN
    Peng, GF
    Anson, M
    [J]. CEMENT & CONCRETE COMPOSITES, 1999, 21 (01) : 23 - 27
  • [5] Time-temperature analysis of bond strength of a rebar after fire exposure
    Chiang, CH
    Tsai, CL
    [J]. CEMENT AND CONCRETE RESEARCH, 2003, 33 (10) : 1651 - 1654
  • [6] Choi J, 2012, STRUCT ENG MECH, V42, P815
  • [7] The assessment of the structure of Novi Sad Open University damaged in a fire
    Folic, R
    Radonjanin, V
    Malesev, M
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2002, 16 (07) : 427 - 440
  • [8] Fire hazard in bridges: Review, assessment and repair strategies
    Garlock, Maria
    Paya-Zaforteza, Ignacio
    Kodur, Venkatesh
    Gu, Li
    [J]. ENGINEERING STRUCTURES, 2012, 35 : 89 - 98
  • [9] A Case Study on the Rehabilitation of a Fire-Damaged Structure
    Ha, Taehun
    Ko, Jeongwon
    Lee, Sangho
    Kim, Seonwoong
    Jung, Jieun
    Kim, Dae-Jin
    [J]. APPLIED SCIENCES-BASEL, 2016, 6 (05):
  • [10] Concrete strength for fire safety design
    Hertz, KD
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2005, 57 (08) : 445 - 453