Detection of biomolecular surface interactions by transit time measurements with a coplanar transmission line probe

被引:5
|
作者
Chen, Qin [1 ]
Roitman, Daniel [2 ]
Knoesen, Andre [1 ]
机构
[1] Univ Calif Davis, Dept Elect & Comp Engn, Davis, CA 95616 USA
[2] Agilent Technol Labs, Palo Alto, CA 94303 USA
基金
美国国家科学基金会;
关键词
Biosensor; Coplanar waveguide; Transmission line; DIELECTRIC-PROPERTIES; SENSITIVE DETECTION; SOLID INTERFACE; WATER; FILMS; SPECTROSCOPY; SYSTEMS; GHZ;
D O I
10.1016/j.sna.2009.03.034
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Changes in the transit time of a short electrical pulse propagating through a coplanar transmission line (CTL) are used to sense protein interactions at an aqueous-solid interface. The effective permittivity of the CTL is lowered as a result of protein binding at the interface. This decrease is sensed by the relative decrease in propagation transit time of a baseband picosecond electrical pulse through the probe. It is shown that the microwave probe is sensitive to protein binding at a liquid-solid interface and can be used for measuring dissociation constants in the nM range. In comparison with previous microwave sensors, this sensor is relatively insensitive to temperature fluctuations. It has the capability of operating in non-optical environments such as porous capillaries, capillaries filled with separation media, or opaque substrates. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 159
页数:9
相关论文
共 50 条
  • [1] Time domain transmission line dielectric probe for detection of biomolecular interactions
    Chen, Q
    Roitman, D
    Knoesen, A
    LAB - ON - A - CHIP: PLATFORMS, DEVICES, AND APPLICATIONS, 2004, 5591 : 198 - 204
  • [2] Microwave transmission line dielectric probe to detect biomolecular surface interactions
    Chen, Q
    McMurdie, J
    Roitman, D
    Knoesen, A
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1990 - 1993
  • [3] Transit time coplanar probe for biornolecular interactions at an aqueous-solid interface
    Chen, Qin
    Roitman, Daniel
    Knoesen, Andre
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 133 (02) : 480 - 485
  • [4] A THICK-FILM COPLANAR PROBE FOR TIME DOMAIN MEASUREMENTS
    MUTHUKRISHNAN, N
    RIAD, SM
    ELSHABINIRIAD, A
    IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1989, 12 (02): : 297 - 302
  • [5] Enzymatic manipulation of surface biomolecular nanostructures for the detection of bioaffinity interactions with SPR imaging and fluorescence measurements
    Lee, Hye Jin
    Wark, Alastair
    Corn, Robert M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [6] Observations on Substrate Characterisation through Coplanar Transmission Line Impedance Measurements.
    Floyd, Liam
    Pike, John
    Tao, Jing
    Jackson, Nathan
    PROCEEDINGS OF THE 2015 IEEE INTERNATIONAL CONFERENCE ON MICROELECTRONIC TEST STRUCTURES (ICMTS 2015), 2015, : 224 - 229
  • [7] On solitons: the biomolecular nonlinear transmission line models with constant and time variable coefficients
    Raza, Nauman
    Murtaza, Isma Ghulam
    Sial, Sultan
    Younis, Muhammad
    WAVES IN RANDOM AND COMPLEX MEDIA, 2018, 28 (03) : 553 - 569
  • [8] Dielectric spectroscopy of a thin surface layer by differential time-domain reflectometry using a coplanar waveguide circuit line probe
    Shirakashi, R.
    Ogawa, T.
    Yamada, J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (02)
  • [10] On-chip CMOS coplanar transmission line measurements and model verification up to 50 GHz
    Goren, D.
    Sheinman, B.
    Woods, W.
    Rascoe, J.
    Shlafman, S.
    2008 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, COMMUNICATIONS, ANTENNAS AND ELECTRONIC SYSTEMS, 2008, : 126 - +