First-in-man randomised comparison of a novel sirolimus-eluting stent with abluminal biodegradable polymer and thin-strut cobalt-chromium alloy: INSPIRON-I trial

被引:22
|
作者
Ribeiro, Expedito E. [1 ]
Campos, Carlos M. [1 ,2 ]
Ribeiro, Henrique B. [1 ]
Lopes, Augusto C. [3 ,4 ]
Esper, Rodrigo B. [1 ]
Meirelles, George X. [5 ]
Perin, Marco A. [1 ]
Abizaid, Alexandre [6 ]
Lemos, Pedro A. [1 ]
机构
[1] Univ Sao Paulo, Dept Intervent Cardiol, Heart Inst InCor, BR-05403900 Sao Paulo, Brazil
[2] Erasmus MC, Thoraxctr, Dept Intervent Cardiol, Rotterdam, Netherlands
[3] MIT, Inst Med Engn & Sci, Cambridge, MA 02139 USA
[4] Harvard Univ, Brigham & Womens Hosp, Cardiovasc Div, Dept Med,Med Sch, Boston, MA 02115 USA
[5] Hosp Servidor Publ Estadual, Dept Cardiol, Sao Paulo, Brazil
[6] Inst Dante Pazzanese Cardiol, Sao Paulo, Brazil
关键词
biodegradable polymer; drug-eluting stent; percutaneous coronary intervention; sirolimus-eluting stent; CORONARY-ARTERIES; DRUG; THROMBOSIS; RISK;
D O I
10.4244/EIJV9I12A234
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The INSPIRON-I trial is a first-in-man evaluation of the safety and efficacy of the Inspiron drug-eluting stent, a sirolimus-eluting stent with abluminal biodegradable polymer coating and thin cobalt-chromium alloy. Methods and results: This is a randomised, multicentre comparison between Inspiron and a stent with the same metallic structure but without polymer coating or drug elution (Cronus). The primary objective was to evaluate the in-segment late loss (LLL) at six months. Secondary endpoints included percent in-stent obstruction as measured by intravascular ultrasound (IVUS) at six months and major adverse cardiac events (MACE). Fifty-eight patients were enrolled (60 lesions), 39 for Inspiron and 19 for Cronus. Baseline clinical and angiographic characteristics of both groups were similar. At six months, the in-segment LLL was reduced in the Inspiron group compared to the control group (0.19 +/- 0.16 mm vs. 0.58 +/- 0.4 mm, respectively; p<0.001), as well as the percent neointimal obstruction (7.8 +/- 7.1% vs. 26.5 +/- 11.4%; p<0.001). At two-year follow-up, incidence of MACE was similar between groups (7.9 vs. 21.1%, respectively; p=0.20), with lower target lesion revascularisation for Inspiron (0 vs. 21.1%, respectively; p=0.01) and no stent thrombosis. Conclusions: Sirolimus eluted from an abluminal biodegradable polymer on a cobalt-chromium alloy proved effective in reducing restenosis at six months.
引用
收藏
页码:1380 / 1384
页数:5
相关论文
共 35 条
  • [1] A Randomized Comparison of Novel Biodegradable Polymer- and Durable Polymer-Coated Cobalt-Chromium Sirolimus-Eluting Stents
    Han, Yaling
    Xu, Bo
    Jing, Quanmin
    Lu, Shuzheng
    Yang, Lixia
    Xu, Kai
    Li, Yi
    Li, Jing
    Guan, Changdong
    Kirtane, Ajay J.
    Yang, Yuejin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (12) : 1352 - 1360
  • [2] First-in-man randomised comparison of the BuMA Supreme biodegradable polymer sirolimus-eluting stent versus a durable polymer zotarolimus-eluting coronary stent: the PIONEER trial
    von Birgelen, Clemens
    Asano, Taku
    Amoroso, Giovanni
    Aminian, Adel
    Brugaletta, Salvatore
    Vrolix, Mathias
    Hernandez-Antolin, Rosana
    van de Harst, Pim
    Iniguez, Andres
    Janssens, Luc
    Smits, Pieter C.
    Wykrzykowska, Joanna J.
    Ribeiro, Vasco Gama
    Pereira, Helder
    da Silva, Pedro Canas
    Piek, Jan J.
    Onuma, Yoshinobu
    Serruys, Patrick W.
    Sabate, Manel
    EUROINTERVENTION, 2018, 13 (17) : 2026 - 2035
  • [3] A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial
    Gao, Run-Lin
    Xu, Bo
    Lansky, Alexandra J.
    Yang, Yue-Jin
    Ma, Chang-Sheng
    Han, Ya-Ling
    Chen, Shao-Liang
    Li, Hui
    Zhang, Rui-Yan
    Fu, Guo-Sheng
    Yuan, Zu-Yi
    Jiang, Hong
    Huo, Yong
    Li, Wei
    Zhang, Yao-Jun
    Leon, Martin B.
    EUROINTERVENTION, 2013, 9 (01) : 75 - 83
  • [4] Randomized comparison of novel biodegradable polymer and durable polymer-coated cobalt-chromium sirolimus-eluting stents: Three-Year Outcomes of the I-LOVE-IT 2 Trial
    Song, Lei
    Li, Jing
    Guan, Changdong
    Jing, Quanmin
    Lu, Shuzheng
    Yang, Lixia
    Xu, Kai
    Yang, Yuejin
    Xu, Bo
    Han, Yaling
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 : 608 - 616
  • [5] One-year performance of thin-strut cobalt chromium sirolimus-eluting stent versus thicker strut stainless steel biolimus-eluting coronary stent: a propensity-matched analysis of two international all-comers registries
    Vlieger, Selina
    Danzi, Gian B.
    Kauer, Floris
    Oemrawsingh, Rohit M.
    Stojkovic, Sinisa
    IJsselmuiden, Alexander J. J.
    Routledge, Helen
    Laanmets, Peep
    Roffi, Marco
    Frobert, Ole
    Baello, Pascual
    Wlodarczak, Adrian
    Puentes, Angel
    Polad, Jawed
    Hildick-Smith, David
    CORONARY ARTERY DISEASE, 2021, 32 (05) : 391 - 396
  • [6] First-in-man study of dedicated bifurcation cobalt-chromium sirolimus-eluting stent BiOSS LIM C® - three-month results
    Gil, Robert J.
    Bil, Jacek
    Kern, Adam
    Pawlowski, Tomasz
    KARDIOLOGIA POLSKA, 2018, 76 (02) : 464 - 470
  • [7] Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention The SORT OUT VII Trial
    Jensen, Lisette Okkels
    Thayssen, Per
    Maeng, Michael
    Ravkilde, Jan
    Krusell, Lars Romer
    Raungaard, Bent
    Junker, Anders
    Terkelsen, Christian Juhl
    Veien, Karsten Tange
    Villadsen, Anton Boel
    Kaltoft, Anne
    Tilsted, Hans-Henrik
    Hansen, Knud Norregaard
    Aaroe, Jens
    Kristensen, Steen Dalby
    Hansen, Henrik Steen
    Jensen, Svend Eggert
    Madsen, Morten
    Botker, Hans Erik
    Berencsi, Klara
    Lassen, Jens Flensted
    Christiansen, Evald Hoj
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07)
  • [8] A prospective multicentre randomised all-comers trial to assess the safety and effectiveness of the thin-strut sirolimus-eluting coronary stent SUPRAFLEX: rationale and design of the Thin Strut Sirolimus-eluting Stent in All Comers Population vs Everolimus-eluting Stent (TALENT) trial
    Modolo, Rodrigo
    Chichareon, Ply
    Kogame, Norihiro
    Asano, Taku
    Chang, Chun Chin
    de Winter, Robbert J.
    Kaul, Upendra
    Zaman, Azfar
    Spitzer, Ernest
    Takahashi, Kuniaki
    Katagiri, Yuki
    Soliman, Osama
    van Es, Gerrit A.
    Morel, Marie-Angele
    Onuma, Yoshinobu
    Serruys, Patrick W.
    EUROINTERVENTION, 2019, 15 (04) : E362 - E369
  • [9] Comparison of the Ultrathin Strut, Biodegradable Polymer Sirolimus-eluting Stent With a Durable Polymer Everolimus-eluting Stent in a Chinese Population: The Randomized BIOFLOW VI Trial
    Li, Chongjian
    Yang, Yuejin
    Han, Yaling
    Song, Dan
    Xu, Jing
    Guan, Changdong
    Gao, Runlin
    Garcia-Garcia, Hector M.
    Waksman, Ron
    Xu, Bo
    CLINICAL THERAPEUTICS, 2020, 42 (04) : 649 - +
  • [10] Outcomes of a novel thin-strut bioresorbable-polymer sirolimus-eluting stent in patients with chronic total occlusions: A multicenter registry
    Azzalini, Lorenzo
    Demir, Ozan M.
    Gasparini, Agabriele L.
    Grancini, Luca
    La Manna, Alessio
    Ojeda, Soledad
    Benincasa, Susanna
    Bellini, Barbara
    Poletti, Enrico
    Maccagni, Davide
    Soldi, Margherita
    Lannetta, Loredana
    Trabattoni, Daniela
    Gravina, Giacomo
    Hidalgo, Francisco
    Giannini, Francesco
    Pan, Manuel
    Tamburino, Corrado
    Bartorelli, Antonio L.
    Reimers, Bernhard
    Godino, Cosmo
    Carlino, Mauro
    Colombo, Antonio
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 258 : 36 - 41