Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma-mass spectrometry in wine analysis

被引:19
作者
Grindlay, Guillermo [1 ,2 ]
Mora, Juan [1 ]
de Loos-Vollebregt, Margaretha T. C. [2 ,3 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, E-03080 Alicante, Spain
[2] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[3] Delft Univ Technol, Fac Appl Sci Analyt Biotechnol, NL-2628 BC Delft, Netherlands
关键词
Spectral interference; Collision/reaction cell; ICP-MS; Multi-element analysis; Wine; ICP-MS; TRACE-ELEMENTS; METALS; INTERFERENCES; SYSTEM;
D O I
10.1016/j.talanta.2014.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work explores the multi-element capabilities of inductively coupled plasma-mass spectrometry with collision/reaction cell technology (CCT-ICP-MS) for the simultaneous determination of both spectrally interfered and non-interfered nuclides in wine samples using a single set of experimental conditions. The influence of the cell gas type (i.e. He, He+H-2 and He+NH3), cell gas flow rate and sample pre-treatment (i.e. water dilution or acid digestion) on the background-equivalent concentration (BEC) of several nuclides covering the mass range from 7 to 238 u has been studied. Results obtained in this work show that, operating the collision/reaction cell with a compromise cell gas flow rate (i.e. 4 mL min(-1)) improves BEC values for interfered nuclides without a significant effect on the BECs for non-interfered nuclides, with the exception of the light elements Li and Be. Among the different cell gas mixtures tested, the use of He or He+H-2 is preferred over He+NH3 because NH3 generates new spectral interferences. No significant influence of the sample pre-treatment methodology (i.e. dilution or digestion) on the multi-element capabilities of CCT-ICP-MS in the context of simultaneous analysis of interfered and non-interfered nuclides was observed. Nonetheless, sample dilution should be kept at minimum to ensure that light nuclides could be quantified in wine. Finally, a direct 5-fold aqueous dilution is recommended for the simultaneous trace and ultra-trace determination of spectrally interfered and non-interfered elements in wine by means of CCT-ICP-MS. The use of the CCT is mandatory for interference-free ultra-trace determination of Ti and Cr. Only Be could not be determined when using the CCT due to a deteriorated limit of detection when compared to conventional ICP-MS. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 50 条
  • [41] Heavy metals in aromatic spices by inductively coupled plasma-mass spectrometry
    Bua, Daniel Giuseppe
    Annuario, Giovanni
    Albergamo, Ambrogina
    Cicero, Nicola
    Dugo, Giacomo
    FOOD ADDITIVES & CONTAMINANTS PART B-SURVEILLANCE, 2016, 9 (03): : 210 - 216
  • [42] Minireview: Advances in Germanium Isotope Analysis by Multiple Collector-Inductively Coupled Plasma-Mass Spectrometry
    Meng, Yu-Miao
    Hu, Rui-Zhong
    ANALYTICAL LETTERS, 2018, 51 (05) : 627 - 647
  • [43] Determination of Trace As and Se in Complex Matrix Sample by Inductively Coupled Plasma-Mass Spectrometry with O2 Collision/Reaction Cell
    Lu Bing-Yuan
    Lu Wen-Wei
    Zhu Wei-Lin
    Lu Yan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (12) : 1781 - 1785
  • [44] Characterization of plastic films from trace element analysis using inductively coupled plasma-mass spectrometry
    Nissen, KE
    Keegan, JT
    Byrne, JP
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 1998, 43 (04): : 122 - 128
  • [45] Determination of total and partially extractable solid-bound element concentrations using collision/reaction cell inductively coupled plasma-mass spectrometry and their significance in environmental studies
    Nurdan S. Duzgoren-Aydin
    Bharathi Avula
    Kristine L. Willett
    Ikhlas A. Khan
    Environmental Monitoring and Assessment, 2011, 172 : 51 - 66
  • [46] Multi-element analysis of spices by inductively coupled plasma mass spectrometry and human risk assessment in the Rabat-Sale-Temara area (Morocco)
    El Youssfi, Mourad
    Flayou, Majda
    El Idrissi, Zineb Lakhlifi
    Ben Ali, Majda
    Bennani, Mohamed
    El Hamidi, Adnane
    Ben Aakame, Rachid
    Laghzizil, Abdelaziz
    Zinedine, Abdellah
    Sifou, Aicha
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 140
  • [47] Multi-element analysis of bread, cheese, fruit and vegetables by double-focusing sector-field inductively coupled plasma mass spectrometry
    Khouzam, Rola Bou
    Lobinski, Ryszard
    Pohl, Pawel
    ANALYTICAL METHODS, 2011, 3 (09) : 2115 - 2120
  • [48] Determination of Major and Trace Elements in Plant Samples by Inductively Coupled Plasma-Mass Spectrometry
    Masson, P.
    Dalix, T.
    Bussiere, S.
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2010, 41 (03) : 231 - 243
  • [49] Determination of Se at low concentration in coal by collision/reaction cell technology inductively coupled plasma mass spectrometry
    Henn, Alessandra S.
    Rondan, Filipe S.
    Mesko, Marcia F.
    Mello, Paola A.
    Perez, Magali
    Armstrong, Joseph
    Bullock, Liam A.
    Parnell, John
    Feldmann, Joerg
    Flores, Erico M. M.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 143 : 48 - 54
  • [50] Recent advances in single-cell analysis by inductively coupled plasma-mass spectrometry: A review
    Yu X.
    He M.
    Chen B.
    Hu B.
    Hu, Bin (binhu@whu.edu.cn), 1600, Elsevier B.V. (1137): : 191 - 207