Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma-mass spectrometry in wine analysis

被引:19
作者
Grindlay, Guillermo [1 ,2 ]
Mora, Juan [1 ]
de Loos-Vollebregt, Margaretha T. C. [2 ,3 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, E-03080 Alicante, Spain
[2] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[3] Delft Univ Technol, Fac Appl Sci Analyt Biotechnol, NL-2628 BC Delft, Netherlands
关键词
Spectral interference; Collision/reaction cell; ICP-MS; Multi-element analysis; Wine; ICP-MS; TRACE-ELEMENTS; METALS; INTERFERENCES; SYSTEM;
D O I
10.1016/j.talanta.2014.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work explores the multi-element capabilities of inductively coupled plasma-mass spectrometry with collision/reaction cell technology (CCT-ICP-MS) for the simultaneous determination of both spectrally interfered and non-interfered nuclides in wine samples using a single set of experimental conditions. The influence of the cell gas type (i.e. He, He+H-2 and He+NH3), cell gas flow rate and sample pre-treatment (i.e. water dilution or acid digestion) on the background-equivalent concentration (BEC) of several nuclides covering the mass range from 7 to 238 u has been studied. Results obtained in this work show that, operating the collision/reaction cell with a compromise cell gas flow rate (i.e. 4 mL min(-1)) improves BEC values for interfered nuclides without a significant effect on the BECs for non-interfered nuclides, with the exception of the light elements Li and Be. Among the different cell gas mixtures tested, the use of He or He+H-2 is preferred over He+NH3 because NH3 generates new spectral interferences. No significant influence of the sample pre-treatment methodology (i.e. dilution or digestion) on the multi-element capabilities of CCT-ICP-MS in the context of simultaneous analysis of interfered and non-interfered nuclides was observed. Nonetheless, sample dilution should be kept at minimum to ensure that light nuclides could be quantified in wine. Finally, a direct 5-fold aqueous dilution is recommended for the simultaneous trace and ultra-trace determination of spectrally interfered and non-interfered elements in wine by means of CCT-ICP-MS. The use of the CCT is mandatory for interference-free ultra-trace determination of Ti and Cr. Only Be could not be determined when using the CCT due to a deteriorated limit of detection when compared to conventional ICP-MS. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 50 条
  • [31] Advantages of N2 and Ar as reaction gases for measurement of multiple Se isotopes using inductively coupled plasma-mass spectrometry with a collision/reaction cell
    Olesik, John W.
    Gray, Patrick J.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 100 : 197 - 210
  • [32] INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY IN GEOCHEMISTRY
    FALKNER, KK
    KLINKHAMMER, GP
    UNGERER, CA
    CHRISTIE, DM
    ANNUAL REVIEW OF EARTH AND PLANETARY SCIENCES, 1995, 23 : 409 - 449
  • [33] Warning diagnostics for inductively coupled plasma-mass spectrometry
    Ying, H
    Murphy, J
    Tromp, JW
    Mermet, JM
    Salin, ED
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (04) : 311 - 326
  • [34] Multi-Element Analysis of Wild Chinese Honeylocust Fruit by Inductively Coupled Plasma Tandem Mass Spectrometry (ICP-MS/MS)
    Jiang Bo
    Huang Jian-hua
    Liu Wei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (12) : 3859 - 3864
  • [35] Method validation of multi-element panel in whole blood by inductively coupled plasma mass spectrometry (ICP-MS)
    Bajaj, Amol O.
    Parker, Rebecca
    Farnsworth, Candice
    Law, Christian
    Johnson-Davis, Kamisha L.
    JOURNAL OF MASS SPECTROMETRY AND ADVANCES IN THE CLINICAL LAB, 2023, 27 : 33 - 39
  • [36] Analytical capabilities of inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometry (ICP-oa-TOF-MS) for multi-element analysis of food and beverages
    Husakova, Lenka
    Urbanova, Iva
    Sramkova, Jitka
    Cernohorsky, Tomas
    Krejcova, Anna
    Bednarikova, Marie
    Frydova, Eva
    Nedelkova, Iva
    Pilarova, Lucie
    FOOD CHEMISTRY, 2011, 129 (03) : 1287 - 1296
  • [37] Fundamental Studies Related to Elemental Isotope Selection for Quantitative Analysis by Inductively Coupled Plasma-Mass Spectrometry with a Helium Collision Cell
    Kero, Frank A.
    Moore, Lucas R.
    Malson, Jeff
    SPECTROSCOPY, 2012, 27 (12) : 24 - 29
  • [38] A provenance study of iron archaeological artefacts by Inductively Coupled Plasma-Mass Spectrometry multi-elemental analysis
    Desaulty, Anne-Marie
    Mariet, Clarisse
    Dillmann, Philippe
    Joron, Jean Louis
    Fluzin, Philippe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (11) : 1253 - 1262
  • [39] Dokha brand differentiation by elemental analysis measured by inductively coupled plasma-Mass spectrometry
    Thomas, Orianna
    Belunis, Amanda
    Alibozek, Rachel
    Hondrogiannis, Ellen M.
    JOURNAL OF FORENSIC SCIENCES, 2022, 67 (05) : 1786 - 1800
  • [40] GGR Handbook of Rock and Mineral Analysis Chapter 7 Quadrupole Inductively Coupled Plasma-Mass Spectrometry
    Linge, Kathryn L.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (03) : 543 - 575