Evaluation of the multi-element capabilities of collision/reaction cell inductively coupled plasma-mass spectrometry in wine analysis

被引:19
作者
Grindlay, Guillermo [1 ,2 ]
Mora, Juan [1 ]
de Loos-Vollebregt, Margaretha T. C. [2 ,3 ]
Vanhaecke, Frank [1 ]
机构
[1] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, E-03080 Alicante, Spain
[2] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
[3] Delft Univ Technol, Fac Appl Sci Analyt Biotechnol, NL-2628 BC Delft, Netherlands
关键词
Spectral interference; Collision/reaction cell; ICP-MS; Multi-element analysis; Wine; ICP-MS; TRACE-ELEMENTS; METALS; INTERFERENCES; SYSTEM;
D O I
10.1016/j.talanta.2014.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work explores the multi-element capabilities of inductively coupled plasma-mass spectrometry with collision/reaction cell technology (CCT-ICP-MS) for the simultaneous determination of both spectrally interfered and non-interfered nuclides in wine samples using a single set of experimental conditions. The influence of the cell gas type (i.e. He, He+H-2 and He+NH3), cell gas flow rate and sample pre-treatment (i.e. water dilution or acid digestion) on the background-equivalent concentration (BEC) of several nuclides covering the mass range from 7 to 238 u has been studied. Results obtained in this work show that, operating the collision/reaction cell with a compromise cell gas flow rate (i.e. 4 mL min(-1)) improves BEC values for interfered nuclides without a significant effect on the BECs for non-interfered nuclides, with the exception of the light elements Li and Be. Among the different cell gas mixtures tested, the use of He or He+H-2 is preferred over He+NH3 because NH3 generates new spectral interferences. No significant influence of the sample pre-treatment methodology (i.e. dilution or digestion) on the multi-element capabilities of CCT-ICP-MS in the context of simultaneous analysis of interfered and non-interfered nuclides was observed. Nonetheless, sample dilution should be kept at minimum to ensure that light nuclides could be quantified in wine. Finally, a direct 5-fold aqueous dilution is recommended for the simultaneous trace and ultra-trace determination of spectrally interfered and non-interfered elements in wine by means of CCT-ICP-MS. The use of the CCT is mandatory for interference-free ultra-trace determination of Ti and Cr. Only Be could not be determined when using the CCT due to a deteriorated limit of detection when compared to conventional ICP-MS. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 50 条
  • [1] Geographic characterization of Greek wine by inductively coupled plasma-mass spectrometry macroelemental analysis
    Pasvanka, Konstantina
    Tzachristas, Alexandros
    Kostakis, Marios
    Thomaidis, Nikolaos
    Proestos, Charalampos
    ANALYTICAL LETTERS, 2019, 52 (17) : 2741 - 2750
  • [2] Multi-element analysis in plastics by laser ablation inductively coupled plasma mass spectrometry
    Kayar, Murat
    Izgi, Belgin
    Cimenoglu, M. Akif
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 399 : 10 - 16
  • [3] Attenuation of interference in collision/reaction cell inductively coupled plasma mass spectrometry, using helium and hydrogen as cell gases - application to multi-element analysis of mastic gum
    Rousis, Nikolaos I.
    Pasias, Loannis N.
    Thomaidis, Nikotaos S.
    ANALYTICAL METHODS, 2014, 6 (15) : 5899 - 5908
  • [4] Determination of Metals Content in Wine Samples by Inductively Coupled Plasma-Mass Spectrometry
    Plotka-Wasylka, Justyna
    Frankowski, Marcin
    Simeonov, Vasil
    Polkowska, Zaneta
    Namiesnik, Jacek
    MOLECULES, 2018, 23 (11):
  • [5] Multi-element analysis of urine using dynamic reaction cell inductively coupled plasma mass spectrometry (ICP-DRC-MS) - A practical application
    Brodzka, Renata
    Trzcinka-Ochocka, Malgorzata
    Janasik, Beata
    INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2013, 26 (02) : 302 - 312
  • [6] Multi-element analysis of urine by inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometry
    Husakova, Lenka
    Urbanova, Iva
    Audrlicka-Vavrusova, Lenka
    Sramkova, Jitka
    Cernohorsky, Tomas
    Bednarikova, Marie
    Pilarova, Lucie
    MICROCHIMICA ACTA, 2011, 173 (1-2) : 173 - 181
  • [7] Inductively Coupled Plasma-Mass Spectrometry
    Esaka, Fumitaka
    ANALYTICAL SCIENCES, 2017, 33 (10) : 1097 - +
  • [8] Multi-element Analysis of Ferromanganese Nodules and Crusts by Inductively Coupled Plasma Mass Spectrometry
    Wang, Xiaoyuan
    Yin, Xuebo
    Zeng, Zhigang
    Chen, Shuai
    ATOMIC SPECTROSCOPY, 2019, 40 (05) : 153 - 160
  • [9] Multielemental Analysis of Biodiesel by Dynamic Reaction Cell-Inductively Coupled Plasma-Mass Spectrometry
    Ling, Zhao-Xing
    He, Yang-Ming
    Wang, Ping-Ya
    Zhou, Ying
    Ahmad, Farooq
    Zhao, Fang-Fang
    ANALYTICAL LETTERS, 2016, 49 (15) : 2461 - 2473
  • [10] Multi-element and isotope ratio determinations in foods and clinical samples using inductively coupled plasma-mass spectrometry
    Crews, HM
    Baxter, MJ
    Lewis, DJ
    Havermeister, W
    Fairweather-Tait, SJ
    Harvey, LJ
    Majsak-Newman, G
    TRACE ELEMENTS IN MAN AND ANIMALS - 9, 1997, : 247 - 251