Evolving experience with thoracic aortic stent graft repair

被引:117
作者
Cambria, RP
Brewster, DC
Lauterbach, SR
Kaufman, JL
Geller, S
Fan, CM
Greenfield, A
Hilgenberg, A
Clouse, WD
机构
[1] Harvard Univ, Sch Med, Dept Surg, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Radiol, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Div Vasc Surg, Boston, MA 02114 USA
[4] Massachusetts Gen Hosp, Div Vasc Radiol, Boston, MA 02114 USA
[5] Massachusetts Gen Hosp, Thorac Aort Ctr, Boston, MA 02114 USA
关键词
D O I
10.1067/mva.2002.123323
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: We reviewed our initial thoracic aorta (TA) stent graft experience in 28 patients from the perspective of treatment with homemade devices (Dacron over Gianturco Z stents; 14 cases) and a commercial device (Excluder; W.L. Gore Co, Flagstaff, Ariz; 14 cases). Methods: From November 1996 to August 2001, 28 patients with a spectrum of disease (degenerative aneurysm, n = 18; chronic dissection, n = 4; pseudoaneurysm, n = 3, with 1 trauma and 2 anastomotic; intramural hematoma, n = 2; and coarctation, n = 1) underwent TA stent grafting. Clinical parameters included a mean age of 71 years, 12 female (43%) and 16 male (57%) patients, 14 of 28 patients (50%) with major comorbidities that prohibited open repair, and nine of 28 patients (32%) with urgent or ruptured conditions. Seven patients (25%) needed open surgical access to the aorta or iliac artery for either concomitant abdominal aortic aneurysm repair (n = 3) or device deployment (n = 4), and six of 28 patients (21%) needed left subclavian-carotid transposition to provide for an adequate proximal fixation site. Focal (< 15 cm) grafts were used in 19 patients, and the remaining patients had at least two thirds of their descending aorta excluded. Results: The procedural mortality rate was 3.5% (1/28 patients); three additional deaths, (1 device-related) occurred during the mean follow-up period of 17 months. Access artery complications occurred in six of 28 patients (21%), with one fatal. No immediate or late open conversions were performed. One patient needed urgent dilation and stenting of a collapsed stent graft 3 weeks after deployment. Serious systemic complications included temporary dialysis (n = 1), congestive heart failure (n = 1), and unstable angina (n = 1). Complete exclusion of the TA lesion was noted in 27 of 28 cases (96%). No cases of spinal cord ischemia were noted. Ease and accuracy of deployment was superior for the second generation (commercial) device. Conclusion: TA stent graft repair, although in evolution, appears to be a safe and effective alternative to open repair for many patients with a spectrum of TA disease. Prospective trials for individual diseases will be necessary to define its ultimate role.
引用
收藏
页码:1129 / 1135
页数:7
相关论文
共 20 条
[1]   Epidural cooling for spinal cord protection during thoracoabdominal aneurysm repair: A five-year experience [J].
Cambria, RP ;
Davison, JK ;
Carter, C ;
Brewster, DC ;
Chang, YC ;
Clark, KA ;
Atamian, S .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (06) :1093-1101
[2]   Improved prognosis of thoracic aortic aneurysms - A population-based study [J].
Clouse, WD ;
Hallett, JW ;
Schaff, HV .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (22) :1926-1929
[3]   Endovascular stent-graft placement for the treatment of acute aortic dissection [J].
Dake, MD ;
Kato, N ;
Mitchell, RS ;
Semba, CP ;
Razavi, MK ;
Shimono, T ;
Hirano, T ;
Takeda, K ;
Yada, I ;
Miller, DC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20) :1546-1552
[4]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[5]  
DATTILO JB, 2002, IN PRESS J VASC SURG
[6]   Endovascular stent graft repair for aneurysms on the descending thoracic aorta [J].
Ehrlich, M ;
Grabenwoeger, M ;
Cartes-Zumelzu, F ;
Grimm, M ;
Petzl, D ;
Lammer, J ;
Thurnher, S ;
Wolner, E ;
Havel, M .
ANNALS OF THORACIC SURGERY, 1998, 66 (01) :19-24
[7]   Primary endoleakage in endovascular treatment of the thoracic aorta: Importance of intraoperative transesophageal echocardiography [J].
Fattori, R ;
Caldarera, I ;
Rapezzi, C ;
Rocchi, G ;
Napoli, G ;
Parlapiano, M ;
Favali, M ;
Pierangeli, A ;
Gavelli, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 120 (03) :490-495
[8]   Thoracic aortic aneurysms:: Treatment with endovascular self-expandable stent grafts [J].
Grabenwöger, M ;
Hutschala, D ;
Ehrlich, MP ;
Cartes-Zumelzu, F ;
Thurnher, S ;
Lammer, J ;
Wolner, E ;
Havel, M .
ANNALS OF THORACIC SURGERY, 2000, 69 (02) :441-445
[9]   Endovascular repair of descending thoracic aortic aneurysms: an early experience with intermediate-term follow-up [J].
Greenberg, R ;
Resch, T ;
Nyman, U ;
Lindh, M ;
Brunkwall, J ;
Brunkwall, P ;
Malina, M ;
Koul, B ;
Lindblad, B ;
Ivancev, K .
JOURNAL OF VASCULAR SURGERY, 2000, 31 (01) :147-156
[10]   Preliminary report on prediction of spinal cord ischemia in endovascular stent graft repair of thoracic aortic aneurysm by retrievable stent graft [J].
Ishimaru, S ;
Kawaguchi, S ;
Koizumi, N ;
Obitsu, Y ;
Ishikawa, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (04) :811-818