The Detection of Macular Analysis by SD-OCT for Optic Chiasmal Compression Neuropathy and Nasotemporal Overlap

被引:39
|
作者
Akashi, Azusa [1 ]
Kanamori, Akiyasu [1 ]
Ueda, Kaori [1 ]
Matsumoto, Yoshiko [1 ]
Yamada, Yuko [1 ]
Nakamura, Makoto [1 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Surg, Div Ophthalmol, Kobe, Hyogo 6500017, Japan
基金
日本学术振兴会;
关键词
band atrophy; chiasmal compression; optical coherence tomography; ganglion cell layer; retinal nerve fiber layer; NERVE-FIBER LAYER; NASO-TEMPORAL DIVISION; COHERENCE TOMOGRAPHY; BAND ATROPHY; FOURIER-DOMAIN; DIAGNOSTIC ABILITY; GANGLION-CELLS; RETINA; THICKNESS; GLAUCOMA;
D O I
10.1167/iovs.14-14766
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the diagnostic performance of the macular parameters detected by spectral-domain optical coherence tomography (SD-OCT) in band atrophy (BA) eyes. METHODS. Forty-nine BA eyes with permanent temporal hemianopia and 89 normal eyes were enrolled. Any patients who had nasal visual field loss were excluded. Each participant was imaged by three-dimensional (3D) OCT-2000, and 10 3 10 grids in the macula were automatically allocated. The thickness of the macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL) + (GCL+inner plexiform layer [IPL]), and GCL++ (RNFL+GCL+IPL) in both nasal and temporal hemiretina was calculated and compared between the BA and normal eyes. The areas under the receiver operating characteristic curves (AUCs) in these parameters were compared between the nasal hemiretina and the temporal hemiretina. RESULTS. All the parameters in the BA eyes were significantly thinner than those in the normal eyes. The AUCs for the mRNFL, GCL+, and GCL++ thickness in the nasal hemiretina were 0.890, 0.988, and 0.981, respectively. The parameters in the nasal hemiretina showed significantly higher AUCs than those parameters in the temporal hemiretina. In the temporal hemiretina, the damaged grids in the mRNFL were located in the arcuate areas in each hemifield. CONCLUSIONS. The inner macular parameters in the nasal hemiretina exhibited high diagnostic abilities to detect BA. The GCL+ was more affected than mRNFL. The characteristic pattern of mRNFL and GCL+ thinning was implicated in the anatomical architecture regarding the nasotemporal overlap of the crossed and uncrossed fibers around the fovea. (www.umin.ac.jp/ctr number, UMIN000006900.)
引用
收藏
页码:4667 / 4672
页数:6
相关论文
共 50 条
  • [21] Sensitivity and specificity of SS-OCT for detecting macular pathologies vs SD-OCT
    Yeu, Elizabeth
    Berdahl, John P.
    Gupta, Preeya K.
    Patterson, Michael
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (05) : 481 - 485
  • [22] The Ability of Macular Parameters and Circumpapillary Retinal Nerve Fiber Layer by Three SD-OCT Instruments to Diagnose Highly Myopic Glaucoma
    Akashi, Azusa
    Kanamori, Akiyasu
    Nakamura, Makoto
    Fujihara, Masashi
    Yamada, Yuko
    Negi, Akira
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (09) : 6025 - 6032
  • [23] Validation of Macular Choroidal Thickness Measurements from Automated SD-OCT Image Segmentation
    Twa, Michael D.
    Schulle, Krystal L.
    Chiu, Stephanie J.
    Farsiu, Sina
    Berntsen, David A.
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (11) : 1387 - 1398
  • [24] Role of SD-OCT in the diagnosis and prognosis of macular hypoplasia in nystagmus patients
    Bouraoui, R.
    Bouladi, M.
    Nefaa, F.
    Limaiem, R.
    El Matri, L.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2016, 39 (03): : 272 - 276
  • [25] Rationale and Development of an OCT-Based Method for Detection of Glaucomatous Optic Neuropathy
    Liebmann, Jeffrey M.
    Hood, Donald C.
    de Moraes, Carlos Gustavo
    Blumberg, Dana M.
    Harizman, Noga
    Kresch, Yocheved S.
    Tsamis, Emmanouil
    Cioffi, George A.
    JOURNAL OF GLAUCOMA, 2022, 31 (06) : 375 - 381
  • [26] Reproducibility of Thickness Measurements of Macular Inner Retinal Layers Using SD-OCT With or Without Correction of Ocular Rotation
    Hirasawa, Hiroyo
    Araie, Makoto
    Tomidokoro, Atsuo
    Saito, Hitomi
    Iwase, Aiko
    Ohkubo, Shinji
    Sugiyama, Kazuhisa
    Ootani, Tomohiro
    Kishi, Shoji
    Matsushita, Kenji
    Maeda, Naoyuki
    Hangai, Masanori
    Yoshimura, Nagahisa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (04) : 2562 - 2570
  • [27] SD-OCT Imaging of the Retina and Optic Nerve in Normal and Glaucomatous Cats
    Seo, K.
    Rasmussen, C. A.
    Finch, A. K.
    Xiong, K.
    Kaufman, P. L.
    McLellan, G. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [28] Maculopathy with optic nerve pits. Morphological criteria in SD-OCT
    Wehrmann, K.
    Stumpfe, S.
    Pettenkofer, M.
    Feucht, N.
    Lohmann, C.
    Maier, M.
    OPHTHALMOLOGE, 2018, 115 (03): : 216 - 221
  • [29] Spectral domain optical coherence tomography (SD-OCT) assessment of the healthy female canine retina and optic nerve
    Hernandez-Merino, Elena
    Kecova, Helga
    Jacobson, Samantha J.
    Hamouche, Karl N.
    Nzokwe, Richard N.
    Grozdanic, Sinisa D.
    VETERINARY OPHTHALMOLOGY, 2011, 14 (06) : 400 - 405
  • [30] Classification of SD-OCT Volumes for DME Detection: An Anomaly Detection Approach
    Sankara, S.
    Sidibe, D.
    Cheung, Y.
    Wong, T. Y.
    Lamoureux, E.
    Milea, D.
    Meriaudeau, F.
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785