Transcatheter coil occlusion of patent ductus arteriosus and follow-up results

被引:1
作者
Atik, Sezen Ugan [1 ]
Saltik, Irfan Levant [1 ]
机构
[1] Istanbul Univ Cerrahpasa, Cerrahpasa Tip Fak, Cocuk Kardiyol Bil Dali, Istanbul, Turkey
来源
TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY | 2019年 / 47卷 / 04期
关键词
Child; coil; patent ductus arteriosus; transcatheter occlusion; CARDIAC-CATHETERIZATION; PERCUTANEOUS CLOSURE; STATEMENT; HEMOLYSIS; LIGATION; OCCLUDER; MODERATE; DISEASE; YOUNG;
D O I
10.5543/tkda.2019.35405
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Although many articles have been published about transcatheter coil occlusion, few studies have been conducted on the long-term outcomes of patent ductus arteriosus closure with a coil. This study is an examination of the follow-up data of patients who underwent transcatheter patent ductus arteriosus closure with a coil. Methods: Between May 1996 and May 2018, 243 patients underwent transcatheter patent ductus arteriosus closure with a coil. The patients were divided into 2 groups based on the timing of the use of ductal occluders at the facility. Until the end of 2005, every ductus was closed with a coil. Since initiating the use of ductal occluders in 2006, coils are mostly used to close small, elongated ducts, and occasionally, some complex ducts. Results: The median age of the patient was 4.33 years, the median weight was 15 kg, and the median duct diameter was 2 mm. In this study group, 98 (40%) patients were male and 145 were female (60%). The angiographic features of the ductus were classified as type A in 126 patients, type B in 15, type C in 6, type D in 9, type E in 74, and 13 were recorded as other types. In 238 of the patients, the patent ductus arteriosus was successfully closed with a coil. In 5 (2.2%) cases, the procedure was unsuccessful. Echocardiography follow-up continued for an average of 4.1 +/- 4.1 years (1 day-19 years). A residual shunt was observed in 42 patients, and spontaneous occlusion was seen in 29 of the 42 patients. Conclusion: The results of this study indicated that closure of the patent ductus arteriosus with a coil was a safe and effective method.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 50 条
  • [21] Transcatheter occlusion of patent ductus arteriosus with a new detachable coil system (DuctOcclud) - a multicenter clinical trial
    Oho, S
    Ishizawa, A
    Koike, K
    Kobayashi, T
    Nakanishi, T
    Momma, K
    Ino, T
    Nishimoto, K
    Ohkubo, M
    Ono, Y
    Kamiya, T
    Akagi, T
    Kato, H
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1998, 62 (07): : 489 - 493
  • [22] Coil occlusion of the patent ductus arteriosus: Lessons learned
    Sanatani, S
    Potts, JE
    Ryan, A
    Sandor, GGS
    Human, DG
    Culham, JAG
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (02) : 87 - 90
  • [23] Transcatheter Patent Ductus Arteriosus Occlusion in Small Infants
    Schwartz, Matthew C.
    Nykanen, David
    Winner, Lawrence H.
    Perez, Jose
    McMahan, Michael
    Munro, Hamish M.
    Narasimhulu, Sukumar Suguna
    CONGENITAL HEART DISEASE, 2016, 11 (06) : 647 - 655
  • [24] Long-Term Follow-Up after Transvenous Single Coil Embolization of Patent Ductus Arteriosus in Dogs
    Hildebrandt, N.
    Schneider, C.
    Schweigl, T.
    Schneider, M.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (06): : 1400 - 1406
  • [25] Coil occlusion of patent ductus arteriosus associated with right aortic arch
    Rao, PS
    Wagman, AJ
    Chen, SC
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (01) : 79 - 82
  • [26] A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus
    Jin Mei
    Liang Yong-Mei
    Wang Xiao-Fang
    Guo Bao-Jing
    Zheng Ke
    Gu Yan
    Lyu Zhen-Yu
    中华医学杂志英文版, 2015, 128 (17) : 2284 - 2289
  • [27] Coil occlusion for patent ductus arteriosus larger than 3 mm
    Kobayashi, T
    Tomita, H
    Fuse, S
    Takamuro, M
    Hatakeyama, K
    Horita, N
    Tsutsumi, H
    CIRCULATION JOURNAL, 2005, 69 (10) : 1271 - 1274
  • [28] Changes in coil morphology following transcatheter coil occlusion of the patent ductus arteriosus using a modified snare technique
    Dobrolet, NC
    Ettedgui, JA
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (04) : 504 - 509
  • [29] Transcatheter occlusion of the patent ductus arteriosus with a single device technique: comparison between the Cook detachable coil and the Rashkind umbrella device
    Jaeggi, ET
    Fasnacht, M
    Arbenz, U
    Beghetti, M
    Bauersfeld, U
    Friedli, B
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2001, 79 (01) : 71 - 76
  • [30] Transcatheter closure of calcified patent ductus arteriosus in older adult patients: Immediate and 12-month follow-up results
    Gu, Xinghua
    Zhang, Qiuwang
    Sun, Hourong
    Fei, Jianchun
    Zhang, Xiquan
    Kutryk, Michael J.
    CONGENITAL HEART DISEASE, 2017, 12 (03) : 289 - 293