External validation and comparison of three prediction tools for risk of osteoporotic fractures using data from population based electronic health records: retrospective cohort study

被引:63
作者
Dagan, Noa [1 ,2 ]
Cohen-Stavi, Chandra [1 ]
Leventer-Roberts, Maya [1 ,3 ,4 ]
Balicer, Ran D. [1 ,5 ]
机构
[1] Clalit Hlth Serv, Clalit Res Inst, Chief Phys Off, Tel Aviv, Israel
[2] Ben Gurion Univ Negev, Dept Comp Sci, Beer Sheva, Israel
[3] Icahn Sch Med Mt Sinai, Dept Prevent Med, New York, NY 10029 USA
[4] Icahn Sch Med Mt Sinai, Dept Pediat, New York, NY 10029 USA
[5] Ben Gurion Univ Negev, Dept Epidemiol, Beer Sheva, Israel
来源
BMJ-BRITISH MEDICAL JOURNAL | 2017年 / 356卷
关键词
PRIMARY-CARE; HIP FRACTURE; FRAX TOOL; MEN; WOMEN; PERFORMANCE; INSTRUMENTS; PREVENTION; MANAGEMENT; DERIVATION;
D O I
10.1136/bmj.i6755
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To directly compare the performance and externally validate the three most studied prediction tools for osteoporotic fractures-QFracture, FRAX, and Garvan-using data from electronic health records. DESIGN Retrospective cohort study. SETTING Payer provider healthcare organisation in Israel. PARTICIPANTS 1054 815 members aged 50 to 90 years for comparison between tools and cohorts of different age ranges, corresponding to those in each tools' development study, for tool specific external validation. MAIN OUTCOME MEASURE First diagnosis of a major osteoporotic fracture (for QFracture and FRAX tools) and hip fractures (for all three tools) recorded in electronic health records from 2010 to 2014. Observed fracture rates were compared to probabilities predicted retrospectively as of 2010. RESULTS The observed five year hip fracture rate was 2.7% and the rate for major osteoporotic fractures was 7.7%. The areas under the receiver operating curve (AUC) for hip fracture prediction were 82.7% for QFracture, 81.5% for FRAX, and 77.8% for Garvan. For major osteoporotic fractures, AUCs were 71.2% for QFracture and 71.4% for FRAX. All the tools underestimated the fracture risk, but the average observed to predicted ratios and the calibration slopes of FRAX were closest to 1. Tool specific validation analyses yielded hip fracture prediction AUCs of 88.0% for QFracture (among those aged 30-100 years), 81.5% for FRAX (50-90 years), and 71.2% for Garvan (60-95 years). CONCLUSIONS Both QFracture and FRAX had high discriminatory power for hip fracture prediction, with QFracture performing slightly better. This performance gap was more pronounced in previous studies, likely because of broader age inclusion criteria for QFracture validations. The simpler FRAX performed almost as well as QFracture for hip fracture prediction, and may have advantages if some of the input data required for QFracture are not available. However, both tools require calibration before implementation.
引用
收藏
页数:15
相关论文
共 37 条
[31]   Long-term proton pump inhibitor use and risk of osteoporosis and hip fractures: A nationwide population-based and multicenter cohort study using a common data model [J].
Park, Da Hee ;
Seo, Seung In ;
Lee, Kyung Joo ;
Kim, Jinseob ;
Kim, Yerim ;
Seo, Won-Woo ;
Lee, Hyung Seok ;
Shin, Woon Geon ;
Yoo, Jong Jin .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2022, 37 (08) :1534-1543
[32]   Assessing the impact of attachment to primary care and unattachment duration on healthcare utilization and cost in Ontario, Canada: a population-based retrospective cohort study using health administrative data [J].
Fitzsimon, Jonathan ;
Cronin, Shawna ;
Gayowsky, Anastasia ;
St-Amant, Antoine ;
Bjerre, Lise M. .
BMC PRIMARY CARE, 2025, 26 (01)
[33]   A Natural Language Processing Model for COVID-19 Detection Based on Dutch General Practice Electronic Health Records by Using Bidirectional Encoder Representations From Transformers: Development and Validation Study [J].
Homburg, Maarten ;
Meijer, Eline ;
Berends, Matthijs ;
Kupers, Thijmen ;
Hartman, Tim Olde ;
Muris, Jean ;
de Schepper, Evelien ;
Velek, Premysl ;
Kuiper, Jeroen ;
Berger, Marjolein ;
Peters, Lilian .
JOURNAL OF MEDICAL INTERNET RESEARCH, 2023, 25
[34]   “Decline and uneven recovery from 7 common long-term conditions managed in the Catalan primary care after two pandemic years: an observational retrospective population-based study using primary care electronic health records” [J].
Núria Mora ;
Francesc Fina ;
Leonardo Méndez-Boo ;
Roser Cantenys ;
Mència Benítez ;
Nemesio Moreno ;
Elisabet Balló ;
Eduardo Hermosilla ;
Mireia Fàbregas ;
Carolina Guiriguet ;
Xavier Cos ;
Sara Rodoreda ;
Ariadna Mas ;
Yolanda Lejardi ;
Ermengol Coma ;
Manuel Medina .
BMC Primary Care, 24
[35]   Decline and uneven recovery from 7 common long-term conditions managed in the Catalan primary care after two pandemic years: an observational retrospective population-based study using primary care electronic health records [J].
Mora, Nuria ;
Fina, Francesc ;
Mendez-Boo, Leonardo ;
Cantenys, Roser ;
Benitez, Mencia ;
Moreno, Nemesio ;
Ballo, Elisabet ;
Hermosilla, Eduardo ;
Fabregas, Mireia ;
Guiriguet, Carolina ;
Cos, Xavier ;
Rodoreda, Sara ;
Mas, Ariadna ;
Lejardi, Yolanda ;
Coma, Ermengol ;
Medina, Manuel .
BMC PRIMARY CARE, 2023, 24 (01)
[36]   Predicting patient-level new-onset atrial fibrillation from population-based nationwide electronic health records: protocol of FIND-AF for developing a precision medicine prediction model using artificial intelligence [J].
Nadarajah, Ramesh ;
Wu, Jianhua ;
Frangi, Alejandro F. ;
Hogg, David ;
Cowan, Campbell ;
Gale, Chris .
BMJ OPEN, 2021, 11 (11)
[37]   Development and temporal external validation of a simple risk score tool for prediction of outcomes after severe head injury based on admission characteristics from level-1 trauma centre of India using retrospectively collected data [J].
Kamal, Vineet Kumar ;
Pandey, Ravindra Mohan ;
Agrawal, Deepak .
BMJ OPEN, 2021, 11 (01)