Imaging Surrogates of Tumor Response to Therapy: Anatomic and Functional Biomarkers

被引:64
作者
Zhao, Binsheng [1 ,2 ]
Schwartz, Lawrence H. [2 ]
Larson, Steve M. [2 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
关键词
response assessment; surrogate biomarker; functional/molecular imaging; volumetric CT; lung cancer; POSITRON-EMISSION-TOMOGRAPHY; CELL LUNG-CANCER; PROLIFERATION IN-VIVO; DNA FLOW-CYTOMETRY; F-18-FDG PET; PROSTATE-CANCER; METABOLIC MEASUREMENTS; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; PROGNOSTIC VALUE;
D O I
10.2967/jnumed.108.056655
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article addresses the current status of quantitative imaging as a surrogate biomarker for the assessment of tumor response to therapy with non-small cell lung cancer as an example. In addition, the article discusses the limitations of conventional response criteria in the new era of molecular-targeted agent for cancer treatment; the increasing need for more accurate and early response-assessment methods, particularly for volumetric CT; new tumor-specific radiotracers and molecular imaging technologies; and the future applications of molecular imaging with PET for studying various features of cancer metabolism, endocrine status, hypoxia, and oncofetal and differentiation antigens.
引用
收藏
页码:239 / 249
页数:11
相关论文
共 81 条
[21]  
HAMBERG LM, 1994, J NUCL MED, V35, P1308
[22]  
HERHOLZ K, 1992, J NEURO-ONCOL, V12, P159
[23]   Early response assessment using 3′-Deoxy-3′-[18F]fluorothymidine-positron emission tomography in high-grade non-Hodgkin's lymphoma [J].
Herrmann, Ken ;
Wieder, Hinrich A. ;
Buck, Andreas K. ;
Schoeffel, Marion ;
Krause, Bernd-Joachim ;
Fend, Falko ;
Schuster, Tibor ;
zum Bueschenfeld, Christian Meyer ;
Wester, Hans-Juergen ;
Duyster, Justus ;
Peschel, Christian ;
Schwaiger, Markus ;
Dechow, Tobias .
CLINICAL CANCER RESEARCH, 2007, 13 (12) :3552-3558
[24]  
Higashi K, 1998, J NUCL MED, V39, P1016
[25]  
HIGASHI K, 1993, J NUCL MED, V34, P414
[26]   Monitoring response to therapy in cancer using [18F]-2-fluouo-2-deoxy-D-glucose and positron emission tomography:: an overview of different analytical methods [J].
Hoekstra, CJ ;
Paglianiti, I ;
Hoekstra, OS ;
Smit, EF ;
Postmus, PE ;
Teule, GJJ ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (06) :731-743
[27]   Inaccuracy of fixed threshold segmentation for PET [J].
Kirov, A. ;
Danford, C. ;
Schmidtlein, C. ;
Yorke, E. ;
Yahalom, J. ;
Kalaigian, H. ;
Hu, Y. ;
Larson, S. ;
Humm, J. ;
Amols, H. .
MEDICAL PHYSICS, 2006, 33 (06) :2039-2039
[28]   PREPARATION OF C-11-METHYL IODIDE AND ITS USE IN SYNTHESIS OF C-11-METHYL-L-METHIONINE [J].
LANGSTROM, B ;
LUNDQVIST, H .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1976, 27 (07) :357-363
[29]  
Larson SM, 2006, J NUCL MED, V47, P901
[30]  
Larson SM, 2004, J NUCL MED, V45, P366