A Comparison of SF6 Decomposition Characteristics under Corona with Point-to-plane Electrode Defect and Spark with Floating Potential Defect

被引:13
|
作者
Ding, Weidong [1 ]
Li, Guojun [1 ]
Ren, Xiang [1 ]
Yan, Xianglian [2 ]
Li, Feng [3 ]
Zhou, Wenwu [4 ]
Wang, Feng [5 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
[2] China Elect Power Res Inst, Beijing 100192, Peoples R China
[3] Guangdong Power Grid Co Ltd, Elect Power Res Inst, Guangzhou 510080, Guangdong, Peoples R China
[4] China Power Engn Consulting Grp, Northwest Elect Power Design Inst, Xian 710032, Shaanxi, Peoples R China
[5] Hunan Univ, Sch Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
关键词
Corona; decomposition product; floating potential defect; point-to-plane electrode; spark; GAS-PHASE HYDROLYSIS; PARTIAL DISCHARGE; AC CORONA; BREAKDOWN; SOF2; O-2; DC;
D O I
10.1109/TDEI.2015.004752
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Corona and spark are two typical discharge types in gas-insulated switchgear (GIS). Studies on the SF6 decomposition characteristics under corona and spark are significant for the safe operation of the GIS. In this paper, the discharge energy/charge and SF6 decomposition products under ac corona with point-to-plane electrode defect and spark with floating potential defect were investigated under different electrode dimensions, applied voltages, SF6 gas pressures, adsorbents and moisture contents. The upper limit of the formation rates, feature extraction, and the amount of wear of the GIS were also discussed. The results show that the influences of gas pressure and moisture content on the discharge energy and SF6 decomposition products under two different defects are distinguishable. In addition, the concentration ratios of (SOF2+SO2)/(SO2F2) under corona and spark lie in the ranges, 0-1, and 1-5, respectively. The formation rates of SF6 decomposition products calculated from experimental results under corona discharge lie in the range, 0.1-5 mu moles/J. However, the formation rates under spark are usually in the range, 0.02-0.04 mu moles/J, which are far lower than that under corona. Theoretically the upper limit of the formation rates under corona and spark are estimated to be in the ranges, 67-540 mu moles/J, and 188-376 nmoles/J respectively. Besides, the concentration ratios and formation rates can be used to distinguish the discharge types and the amount of wear of the GIS can be estimated.
引用
收藏
页码:3278 / 3289
页数:12
相关论文
共 34 条
  • [1] Decomposition Characteristics of SF6 under Partial Discharges with Point-to-plane Electrode Defect
    Ding Weidong
    Zhou Wenwu
    Ren Xiang
    Li Guojun
    Fan Chuan
    Duan Wei
    Song Gao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (05) : 1727 - 1736
  • [2] Decomposition Characteristics of SF6 Under Different Spark Energies
    Tang, J.
    Liu, X.
    Rao, X. J.
    Zeng, F. P.
    Yao, Q.
    Miao, Y. L.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (06) : 3346 - 3354
  • [3] Decomposition Characteristics of By-products of SF6 Under Different Spark Energies
    Yue, X. G.
    Liu, X.
    Yao, Q.
    Miao, Y. L.
    Tang, J.
    Zeng, F. P.
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 45 - 48
  • [4] Experimental Study on SF6 Decomposition Characteristics under Spark Discharges
    Lin, Tao
    Han, Dong
    Zhang, Guoqiang
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 1003 - 1006
  • [5] Investigation on SF6 Spark Decomposition Characteristics Under Different Pressures
    Tang, Ju
    Rao, Xiajin
    Tang, Bowen
    Liu, Xin
    Gong, Xun
    Zeng, Fuping
    Yao, Qiang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (04) : 2066 - 2075
  • [6] Partial Discharge Characteristics of Void Defect in SF6 under Stepped AC Voltage
    Widodo, Rusli
    Suwarno
    Zhu, Ming-Xiao
    Zhang, Guan-Jun
    5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, 2015, : 181 - 185
  • [7] Partial Discharge Characteristics of Surface Defect in SF6 Under Oscillating Impulse Voltage
    Han, Xutao
    Pang, Peichuan
    Zhang, Liang
    Zhang, Qian
    Li, Junhao
    2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [8] Effects of voltage forms, pressure, and adsorbent on the SF6 decomposition characteristics under corona discharge
    Zhong, Lipeng
    Liu, Kai
    Ji, Shengchang
    Wang, Feng
    Sun, Qiuqin
    Chen, She
    Liu, Jie
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2020, 14 (04) : 486 - 493
  • [9] Correlation Characteristics between SF6 Decomposition Process and Partial Discharge Quantity under Negative DC Condition initiated by Free Metal Particle Defect
    Yang, Dong
    Tang, Ju
    Zeng, Fuping
    Yang, Xu
    Yao, Qiang
    Miao, Yulong
    Chen, Lincong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (02) : 574 - 583
  • [10] Partial discharge on SF6 needle-plane defect under negative oscillating lighting impulse voltage
    Zhang L.
    Che B.
    Han X.
    Li J.
    Xiong J.
    Wang S.
    Li, Junhao, 2016, Xi'an Jiaotong University (50): : 108 - 116