Experimental evaluation of a 1.x-effect ejector-absorption refrigeration system

被引:7
|
作者
Yan, Xiaona [1 ,2 ]
Shi, Yuqi [3 ]
Wang, Lin [2 ]
Hong, Daliang [4 ]
Chen, Guangming [5 ]
机构
[1] Zhejiang A&F Univ, Sch Landscape Architecture, Hangzhou 311300, Zhejiang, Peoples R China
[2] Henan Univ Sci & Technol, Lab Refrigerat Heat Pump & Air Conditioning Techn, Luoyang 471023, Peoples R China
[3] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ene, MOE, Tianjin 300072, Peoples R China
[4] China Elect Technol Grp Corp 38 Res Inst, Hefei, Anhui, Peoples R China
[5] Zhejiang Univ, Key Lab Refrigerat & Cryogen Technol Zhejiang Pro, Inst Refrigerat & Cryogen, Hangzhou, Zhejiang, Peoples R China
关键词
Absorption refrigeration; 1.x effect; Ejector-absorption combined; Experimental; EXERGY ANALYSIS; FLASH TANK; DRIVEN; CYCLE; FLOW;
D O I
10.1016/j.applthermaleng.2019.113738
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a 1.x-effect (hybrid ejector-absorption refrigeration working between single-effect and double effect) cycle is evaluated experimentally. Through the use of the ejector, the external heat sources' grade is reduced. Part of the refrigerant vapor at the outlet of the low-pressure generator is directly entrained by the refrigerant vapor from the outlet of the high-pressure generator to the condenser. The system with 10 kW cooling load is experimentally studied. The COP of the system is 30.0% higher than a single-effect absorption refrigeration system, and generation temperature is at least 20 degrees C lower than a double-effect absorption refrigeration system.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation of adding flash tank to solar combined ejector-absorption refrigeration system
    Sirwan, Ranj
    Alghoul, M. A.
    Sopian, K.
    Ali, Yusoff
    Abdulateef, Jasim
    SOLAR ENERGY, 2013, 91 : 283 - 296
  • [2] Hybrid Ejector-Absorption Refrigeration Systems: A Review
    Mukhtar, Hamza K.
    Ghani, Saud
    ENERGIES, 2021, 14 (20)
  • [3] A novel ejector-absorption combined refrigeration cycle
    Hong, Daliang
    Chen, Guangming
    Tang, Limin
    He, Yijian
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (07): : 1596 - 1603
  • [4] Evaluation of a novel combined ejector-absorption refrigeration cycle .1. Computer simulation
    Sun, DW
    Eames, IW
    Aphornratana, S
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1996, 19 (03): : 172 - 180
  • [5] Thermodynamic analysis and comparison of combined ejector-absorption and single effect absorption refrigeration systems
    Farshi, L. Garousi
    Mosaffa, A. H.
    Ferreira, C. A. Infante
    Rosen, M. A.
    APPLIED ENERGY, 2014, 133 : 335 - 346
  • [6] Evaluation of a novel combined ejector-absorption refrigeration cycle - I: computer simulation
    Natl Univ of Ireland, Dublin, Ireland
    Int J Refrig, 3 (172-180):
  • [7] Study of an ejector-absorption refrigeration cycle with an adaptable ejector nozzle for different working conditions
    Vereda, C.
    Ventas, R.
    Lecuona, A.
    Venegas, M.
    APPLIED ENERGY, 2012, 97 : 305 - 312
  • [8] Experimental investigation of a combined ejector-absorption refrigerator
    Aphornratana, S
    Eames, IW
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1998, 22 (03) : 195 - 207
  • [9] Experimental study of a new ejector-absorption refrigeration cycle driven by multi-heat sources
    Shi, Yuqi
    Li, Fei
    Hong, Daliang
    Wang, Qin
    Chen, Guangming
    APPLIED THERMAL ENGINEERING, 2018, 133 : 604 - 612
  • [10] Thermodynamic analysis of a biomass gasifier driven combined power and ejector-absorption refrigeration (CPER) system
    Parvez M.