Assessment of the myocardial area at risk: comparing T2-weighted cardiovascular magnetic resonance imaging with contrast-enhanced cine (CE-SSFP) imaging-a DANAMI3 substudy

被引:12
|
作者
Goeransson, Christoffer [1 ]
Ahtarovski, Kiril Aleksov [1 ]
Kyhl, Kasper [1 ]
Lonborg, Jacob [1 ]
Nepper-Christensen, Lars [1 ]
Bertelsen, Litten [1 ]
Ghotbi, Adam Ali [2 ]
Schoos, Mikkel Malby [1 ]
Kober, Lars [1 ]
Hofsten, Dan [1 ]
Helqvist, Steffen [1 ]
Kelbaek, Henning [3 ]
Engstrom, Thomas [1 ]
Vejlstrup, Niels [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Cardiol, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Dept Clin Physiol Nucl Med & PET, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
[3] Zealand Univ Hosp, Dept Cardiol, Sygehusvej 10, DK-4000 Roskilde, Denmark
关键词
acute myocardial infarction; area at risk; cardiovascular magnetic resonance imaging; INFARCT SIZE; EDEMA; CMR; QUANTIFICATION; VALIDATION; MRI;
D O I
10.1093/ehjci/jey106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Myocardial salvage following treatment for ST-segment elevation myocardial infarction is prognostic for morbidity and mortality. Studies with myocardial salvage as endpoint rely on valid assessment of the myocardial area at risk (AAR). T2-weighted cardiovascular magnetic resonance (CMR) imaging is the preferred method to assess the AAR. However, T2-weighted imaging can be of poor image quality and uninterpretable. Contrast-enhanced (CE) cine imaging can also show AAR and our aim was to investigate if CE-cine can replace T2-weighted imaging. Cine imaging is part of a standard CMR-protocol and implementing CE-cine imaging for assessment of the AAR would mean shorter investigation time. Methods and results As a DANAMI-3 substudy, we performed successful dual imaging of the AAR in 166 participants using both T2-weighted short tau inversion recovery (T2-STIR) and CE-cine imaging. T2-STIR imaging was non-diagnostic in nine and CE-cine in one scan during the period. CE-cine measured 4.7% of left ventricle (LV) [95% confidence interval 3.2-6.2%] smaller AAR compared with T2-STIR images (P<0.001). Visual analysis of a plot of infarct size vs. AAR showed an overestimation of the AAR when measured with T2-STIR images. There was no difference in AAR with CE-cine in an interobserver analysis of 46 scans [1.2 g (standard deviation 9.5), P = 0.42]. Conclusions CE-cine imaging shows good internal consistency in assessment of the AAR. A visual inspection reveals possible overestimation of AAR with T2-STIR images. There is good interobserver agreement in the analysis of CE-cine imaging. CE-cine can replace T2-STIR imaging resulting in a more valid assessment of the myocardial AAR.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 50 条
  • [41] Validation of contrast enhanced cine steady-state free precession and T2-weighted CMR for assessment of ischemic myocardial area-at-risk in the presence of reperfusion injury
    Esben Søvsø Szocska Hansen
    Steen Fjord Pedersen
    Steen Bønløkke Pedersen
    Hans Erik Bøtker
    Won Yong Kim
    The International Journal of Cardiovascular Imaging, 2019, 35 : 1039 - 1045
  • [42] Validation of contrast enhanced cine steady-state free precession and T2-weighted CMR for assessment of ischemic myocardial area-at-risk in the presence of reperfusion injury
    Hansen, Esben Sovso Szocska
    Pedersen, Steen Fjord
    Pedersen, Steen Bonlokke
    Botker, Hans Erik
    Kim, Won Yong
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (06): : 1039 - 1045
  • [43] Dynamic changes of T2-Weighted signal intensity magnetic resonance imaging in reperfused myocardial infarction: implications for retrospective area-at risk quantification
    Rossello, X.
    Fernandez-Friera, L.
    Garcia-Ruiz, J. M.
    Garcia-Alvarez, A.
    Fernandez-Jimenez, R.
    Pizarro, G.
    Dall'armellina, E.
    Fuster, V.
    Choudhury, R. P.
    Ibanez, B.
    EUROPEAN HEART JOURNAL, 2014, 35 : 793 - 794
  • [44] Assessment of depth of myometrial invasion by endometrial carcinoma: comparison of T2-weighted SE and contrast-enhanced dynamic GRE MR imaging
    G. Savci
    T. Ozyaman
    M. Tutar
    T. Bilgin
    O. Erol
    E. Tuncel
    European Radiology, 1998, 8 : 218 - 223
  • [45] Assessment of depth of myometrial invasion by endometrial carcinoma: comparison of T2-weighted SE and contrast-enhanced dynamic GRE MR imaging
    Savci, G
    Ozyaman, T
    Tutar, M
    Bilgin, T
    Erol, O
    Tuncel, E
    EUROPEAN RADIOLOGY, 1998, 8 (02) : 218 - 223
  • [46] In vivo T2-weighted magnetic resonance imaging can accurately determine the ischemic area at risk for 2-day-old nonreperfused myocardial infarction
    Tilak, Gauri S.
    Hsu, Li-Yueh
    Hoyt, Robert F., Jr.
    Arai, Andrew E.
    Aletras, Anthony H.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (01) : 7 - 15
  • [47] ASSESSMENT OF MYOCARDIAL INFARCT SIZE BY MEANS OF T2-WEIGHTED H-1 NUCLEAR MAGNETIC-RESONANCE IMAGING
    BOUCHARD, A
    REEVES, RC
    CRANNEY, G
    BISHOP, SP
    POHOST, GM
    BISCHOFF, P
    AMERICAN HEART JOURNAL, 1989, 117 (02) : 281 - 289
  • [48] A New Approach Towards Improved Visualization of Myocardial Edema Using T2-Weighted Imaging: A Cardiovascular Magnetic Resonance (CMR) Study
    Cocker, Myra S.
    Shea, Steven M.
    Strohm, Oliver
    Green, Jordin
    Abdel-Aty, Hassan
    Friedrich, Matthias G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (02) : 286 - 292
  • [49] Perfusion imaging of cerebral arteriovenous malformations: a study comparing quantitative continuous arterial spin labeling and dynamic contrast-enhanced magnetic resonance imaging at 3 T
    Luedemann, Lutz
    Jedrzejewski, Grzegorz
    Heidenreich, Jens
    Han, Eric T.
    Bruhn, Harald
    MAGNETIC RESONANCE IMAGING, 2011, 29 (09) : 1157 - 1164
  • [50] MYOCARDIUM AREA AT RISK MEASURED WITH DELAYED ENHANCEMENT AFTER SCAR REMODELING COMPARED WITH T2-WEIGHTED CARDIAC MAGNETIC RESONANCE IMAGING
    Loenborg, Jacob
    Vejlstrup, Niels
    Mathiasen, Anders B.
    Engstrom, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E733 - E733