Bonding Performance of Universal Adhesive Systems Applied in Etch-and-Rinse and Self-Etch Strategies on Natural Dentin Caries

被引:28
|
作者
Hass, V [1 ]
Cardenas, A. F. M. [2 ]
Siqueira, F. S. F. [2 ]
Pacheco, R. R. [3 ]
Zago, P. M. W. [4 ]
Silva, D. O. [5 ]
Bandeca, M. C. [6 ]
Loguercio, A. D. [7 ]
机构
[1] Univ North Parana, Postgrad Program Dent, Londrina, Parana, Brazil
[2] CEUMA Univ, Sch Dent, Dept Restorat Dent, Sao Luis, Maranhao, Brazil
[3] Univ Detroit Mercy, Dept Restorat Dent, Detroit, MI 48221 USA
[4] CEUMA Univ, Sch Dent, Sao Luis, Maranhao, Brazil
[5] Univ Ceuma, Postgrad Program Dent, Sao Luis, Brazil
[6] CEUMA Univ, Dept Dent, Sao Luis, Maranhao, Brazil
[7] Univ Estadual Ponta Grossa, Restorat Dent, Uvaranas, Ponta Grossa, Brazil
关键词
IN-VITRO; MATRIX METALLOPROTEINASES; LESIONS; BOTTLE; IMMEDIATE; LONGEVITY; STRENGTH; HARDNESS; ENAMEL; ULTRASTRUCTURE;
D O I
10.2341/17-252-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study investigated the bonding performance of three universal adhesive systems applied using etch-and-rinse (ER) or selfetch (SE) strategies on natural dentin caries. Materials and Methods: Sixty human third molars were selected for this study: 30 naturally carious (CAD) and 30 sound (SD) teeth. The dentin surfaces were exposed, and teeth were randomly assigned to each evaluated adhesive system: Scotchbond Universal (SBU), Futurabond U (FBU), and Prime&Bond Elect (PBE) and an adhesive strategy: ER or SE. The adhesive systems were applied following the manufacturer's instructions, and the teeth were restored using a resin composite (Filtek Supreme Ultra, 3M). After 24 hours (distilled water at 37 degrees C), samples were sectioned and evaluated using microtensile bond strength analysis (mu TBS), micro-Raman spectroscopy to evaluate the degree of conversion within the hybrid layer (DC), and scanning electronic microscopy (SEM) to describe the morphology of the hybrid layer. The mu TBS and DC data were analyzed using three-way analysis of variance and Tukey's test for means comparison (alpha=0.05). The SEM images were analyzed qualitatively. Results: Reduced mu TBS values were observed when comparing CAD with SD, regardless of adhesive system or strategy (p<0.0001). SBU showed statistically higher mu TBS for both dentin substrates and strategies (p<0.0001). Furthermore, SBU showed greater integrity of the hybrid layer and resin tag formation compared with FBU and PBE. Mean mu TBS values for FBU were higher for SD in the SE mode, whereas higher mean mu TBS values were observed for CAD in the ER mode, both compared with PBE (p <0.001). Conclusion: Bonding performance is reduced on a caries-affected substrate. The ER strategy was not able to improve the bonding performance on natural CAD for universal adhesive systems. Improved bonding performance was obtained when using the Scotchbond Universal system.
引用
收藏
页码:510 / 520
页数:11
相关论文
共 50 条
  • [11] Influence of natural and synthetic metalloproteinase inhibitors on bonding durability of an etch-and-rinse adhesive to dentin
    Monteiro, T. M. A.
    Basting, R. T.
    Turssi, C. P.
    Franca, F. M. G.
    Amaral, F. L. B.
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2013, 47 : 83 - 88
  • [12] The evolution of adhesive dentistry: From etch-and-rinse to universal bonding systems
    Breschi, Lorenzo
    Maravic, Tatjana
    Mazzitelli, Claudia
    Josic, Uros
    Mancuso, Edoardo
    Cadenaro, Milena
    Pfeifer, Carmem S.
    Mazzoni, Annalisa
    DENTAL MATERIALS, 2025, 41 (02) : 141 - 158
  • [13] Dentin bonding of an etch-and-rinse adhesive using self- and light-cured composites
    Walter, Ricardo
    Swift, Edward J., Jr.
    Ritter, Andre V.
    Bartholomew, Whitley W.
    Gibson, Christopher G.
    AMERICAN JOURNAL OF DENTISTRY, 2009, 22 (04) : 215 - 218
  • [14] Etch-and-rinse versus self-etch strategy of a universal adhesive in different application methods at the bonding interface of fiber post cementation
    Oliveira Barros, Antonia Patricia
    Alencar, Cristiane de Melo
    Zambon, Matheus
    de Andrade, Marcelo Ferrarezi
    Fernandez, Eduardo
    Kuga, Milton Carlos
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2023, 35 (08) : 1249 - 1256
  • [15] Effect of Mode of Application on the Microtensile Bond Strength of a Self-etch and Etch-and-Rinse Adhesive System
    Reis, A.
    Zander-Grande, C.
    Kossatz, S.
    Stanislawczuk, R.
    Manso, A.
    Carvalho, R. M.
    Loguercio, A. D.
    OPERATIVE DENTISTRY, 2010, 35 (04) : 428 - 435
  • [16] Bonding efficacy of an acetone/based etch-and-rinse adhesive after dentin deproteinization
    Aguilera, Fatima-Sanchez
    Osorio, Raquel
    Osorio, Estrella
    Moura, Pedro
    Toledano, Manuel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2012, 17 (04): : E649 - E654
  • [17] Six-year clinical performance of etch-and-rinse and self-etch adhesives
    Boushell, Lee W.
    Heymann, Harald O.
    Ritter, Andre V.
    Sturdevant, John R.
    Swift, Edward J., Jr.
    Wilder, Aldridge D., Jr.
    Chung, Yunro
    Lambert, Cynthia A.
    Walter, Ricardo
    DENTAL MATERIALS, 2016, 32 (09) : 1065 - 1072
  • [18] EFFECT OF CHLORHEXIDINE ON THE BONDING EFFECT OF AN ETCH-AND-RINSE ADHESIVE TO PRETREATMENT DENTIN
    Jing, Debao
    Wang, Liqin
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 : S146 - S155
  • [19] Effect of green tea extract on bonding durability of an etch-and-rinse adhesive system to caries-affected dentin
    Carvalho, Carolina
    Fernandes, Fernando Pelegrim
    Freitas, Valeria da Penha
    Gomes Franca, Fabiana Mantovani
    Basting, Roberta Tarkany
    Turssi, Cecilia Pedroso
    Botelho do Amaral, Flavia Lucisano
    JOURNAL OF APPLIED ORAL SCIENCE, 2016, 24 (03) : 211 - 217
  • [20] Microtensile bond strength of etch-and-rinse and self-etch adhesive systems to demineralized dentin after the use of a papain-based chemomechanical method
    Gianini, Renato Jose
    Botelho do Amaral, Flavia Lucisano
    Florio, Flavia Martao
    Basting, Roberta Tarkany
    AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (01) : 23 - 28