Inter-Observer and Intra-Observer Variability in Gross Tumor Volume Delineation of Primary Esophageal Carcinomas Based on Different Combinations of Diagnostic Multimodal Images

被引:5
|
作者
Li, Fengxiang [1 ]
Li, Yankang [1 ]
Wang, Xue [2 ]
Zhang, Yingjie [1 ]
Liu, Xijun [1 ]
Liu, Shanshan [1 ]
Wang, Wei [1 ]
Wang, Jinzhi [1 ]
Guo, Yanluan [1 ]
Xu, Min [1 ]
Li, Jianbin [1 ]
机构
[1] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp, Jinan, Peoples R China
[2] Linyi Canc Hosp, Dept Radiat Oncol, Linyi, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
基金
中国国家自然科学基金;
关键词
esophageal carcinoma; diagnostic multimodal images; target delineation; intra-observer variability; inter-observer variability; POSITRON-EMISSION-TOMOGRAPHY; TARGET VOLUME; COMPUTED-TOMOGRAPHY; LUNG-CANCER; CHEMORADIOTHERAPY; RADIOTHERAPY; CT; PET; CHEMORADIATION; DEFINITION;
D O I
10.3389/fonc.2022.817413
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and PurposeThis study aimed to investigate inter-/intra-observer delineation variability in GTVs of primary esophageal carcinomas (ECs) based on planning CT with reference to different combinations of diagnostic multimodal images from endoscopy/EUS, esophagography and FDG-PET/CT. Materials and MethodsFifty patients with pathologically proven thoracic EC who underwent diagnostic multimodal images before concurrent chemoradiotherapy were enrolled. Five radiation oncologist independently delineated the GTVs based on planning CT only (GTV(C)), CT combined with endoscopy/EUS (GTV(CE)), CT combined with endoscopy/EUS and esophagography (X-ray) (GTV(CEX)), and CT combined with endoscopy/EUS, esophagography, and FDG-PET/CT (GTV(CEXP)). The intra-/inter-observer variability in the volume, longitudinal length, generalized CI (CIgen), and position of the GTVs were assessed. ResultsThe intra-/inter-observer variability in the volume and longitudinal length of the GTVs showed no significant differences (p>0.05). The mean intra-observer CIgen values for all observers was 0.73 +/- 0.15. The mean inter-observer CIgen values for the four multimodal image combinations was 0.67 +/- 0.11. The inter-observer CIgen for the four combined images was the largest, showing significant differences with those for the other three combinations. The intra-observer CIgen among different observers and inter-observer CIgen among different combinations of multimodal images showed significant differences (p<0.001). The intra-observer CIgen for the senior radiotherapists was larger than that for the junior radiotherapists (p<0.001). ConclusionFor radiation oncologists with advanced medical imaging training and clinical experience, using diagnostic multimodal images from endoscopy/EUS, esophagography, and FDG-PET/CT could reduce the intra-/inter-observer variability and increase the accuracy of target delineation in primary esophageal carcinomas.
引用
收藏
页数:10
相关论文
共 11 条
  • [11] A PROSPECTIVE STUDY TO DETERMINE INTER-OBSERVER VARIABILITY OF GROSS TUMOR VOLUME WITH FDG-PET/CT COMPARED TO CT ALONE IN STAGE III NON-SMALL CELL LUNG CANCER USING THREE-DIMENSIONAL ANALYSIS
    Peterson, David J.
    Ahmed, Naseer
    Rivest, Ryan
    Bashir, Bashir
    Ahmed, Shahida
    Demeter, Sandor
    Nugent, Zoann
    Brechin, Pam
    Mccurdy, Boyd
    Hunter, William
    Leylek, Ahmet
    Chowdhury, Amit
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S836 - S837