Inter-Observer and Intra-Observer Variability in Gross Tumor Volume Delineation of Primary Esophageal Carcinomas Based on Different Combinations of Diagnostic Multimodal Images

被引:5
|
作者
Li, Fengxiang [1 ]
Li, Yankang [1 ]
Wang, Xue [2 ]
Zhang, Yingjie [1 ]
Liu, Xijun [1 ]
Liu, Shanshan [1 ]
Wang, Wei [1 ]
Wang, Jinzhi [1 ]
Guo, Yanluan [1 ]
Xu, Min [1 ]
Li, Jianbin [1 ]
机构
[1] Shandong First Med Univ & Shandong Acad Med Sci, Shandong Canc Hosp, Jinan, Peoples R China
[2] Linyi Canc Hosp, Dept Radiat Oncol, Linyi, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
基金
中国国家自然科学基金;
关键词
esophageal carcinoma; diagnostic multimodal images; target delineation; intra-observer variability; inter-observer variability; POSITRON-EMISSION-TOMOGRAPHY; TARGET VOLUME; COMPUTED-TOMOGRAPHY; LUNG-CANCER; CHEMORADIOTHERAPY; RADIOTHERAPY; CT; PET; CHEMORADIATION; DEFINITION;
D O I
10.3389/fonc.2022.817413
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and PurposeThis study aimed to investigate inter-/intra-observer delineation variability in GTVs of primary esophageal carcinomas (ECs) based on planning CT with reference to different combinations of diagnostic multimodal images from endoscopy/EUS, esophagography and FDG-PET/CT. Materials and MethodsFifty patients with pathologically proven thoracic EC who underwent diagnostic multimodal images before concurrent chemoradiotherapy were enrolled. Five radiation oncologist independently delineated the GTVs based on planning CT only (GTV(C)), CT combined with endoscopy/EUS (GTV(CE)), CT combined with endoscopy/EUS and esophagography (X-ray) (GTV(CEX)), and CT combined with endoscopy/EUS, esophagography, and FDG-PET/CT (GTV(CEXP)). The intra-/inter-observer variability in the volume, longitudinal length, generalized CI (CIgen), and position of the GTVs were assessed. ResultsThe intra-/inter-observer variability in the volume and longitudinal length of the GTVs showed no significant differences (p>0.05). The mean intra-observer CIgen values for all observers was 0.73 +/- 0.15. The mean inter-observer CIgen values for the four multimodal image combinations was 0.67 +/- 0.11. The inter-observer CIgen for the four combined images was the largest, showing significant differences with those for the other three combinations. The intra-observer CIgen among different observers and inter-observer CIgen among different combinations of multimodal images showed significant differences (p<0.001). The intra-observer CIgen for the senior radiotherapists was larger than that for the junior radiotherapists (p<0.001). ConclusionFor radiation oncologists with advanced medical imaging training and clinical experience, using diagnostic multimodal images from endoscopy/EUS, esophagography, and FDG-PET/CT could reduce the intra-/inter-observer variability and increase the accuracy of target delineation in primary esophageal carcinomas.
引用
收藏
页数:10
相关论文
共 11 条
  • [1] Inter-observer and intra-observer reliability for lung cancer target volume delineation in the 4D-CT era
    Louie, Alexander V.
    Rodrigues, George
    Olsthoorn, Jason
    Palma, David
    Yu, Edward
    Yaremko, Brian
    Ahmad, Bela
    Aivas, Inge
    Gaede, Stewart
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 166 - 171
  • [2] Reduced inter-observer and intra-observer delineation variation in esophageal cancer radiotherapy by use of fiducial markers
    Machiels, Melanie
    Jin, Peng
    van Hooft, Jeanin E.
    Gurney-Champion, Oliver J.
    Jelvehgaran, Pouya
    Geijsen, Elizabeth D.
    Jeene, Paul M.
    Kolff, M. Willemijn
    Oppedijk, Vera
    Rasch, Coen. R. N.
    van Herk, Marcel B.
    Alderliesten, Tanja
    Hulshof, Maarten C. C. M.
    ACTA ONCOLOGICA, 2019, 58 (06) : 943 - 950
  • [3] Definition of gross tumor volume in lung cancer: inter-observer variability
    Van de Steene, J
    Linthout, N
    de Mey, J
    Vinh-Hung, V
    Claassens, C
    Noppen, M
    Bel, A
    Storme, G
    RADIOTHERAPY AND ONCOLOGY, 2002, 62 (01) : 37 - 49
  • [4] Influence of inter-observer delineation variability on radiomics stability in different tumor sites
    Pavic, Matea
    Bogowicz, Marta
    Wurms, Xaver
    Glatz, Stefan
    Finazzi, Tobias
    Riesterer, Oliver
    Roesch, Johannes
    Rudofsky, Leonie
    Friess, Martina
    Veit-Haibach, Patrick
    Huellner, Martin
    Opitz, Isabelle
    Weder, Walter
    Frauenfelder, Thomas
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    ACTA ONCOLOGICA, 2018, 57 (08) : 1070 - 1074
  • [5] Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
    Jaarsma-Coes, Myriam G.
    Klaassen, Lisa
    Verbist, Berit M.
    Vu, T. H. Khanh
    Klaver, Yvonne L. B.
    Rodrigues, Myra F.
    Nabarro, Claire
    Luyten, Gregorius P. M.
    Rasch, Coen R. N.
    van Herk, Marcel
    Beenakker, Jan-Willem M.
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (03)
  • [6] Inter-observer agreement of computed tomography and magnetic resonance imaging on gross tumor volume delineation of intrahepatic cholangiocarcinoma: an initial study
    Zhou, Nan
    Hu, Anning
    Shi, Zhihao
    Wang, Xiaolu
    Zhu, Qiongjie
    Zhou, Qun
    Ma, Jun
    Zhao, Feng
    Kong, Weiwei
    He, Jian
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (02) : 579 - 585
  • [7] INTER-OBSERVER VARIABILITY IN GROSS TUMOUR VOLUME DELINEATION ON KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY (CBCT) SCANS FOR LUNG CANCER RADIOTHERAPY TREATMENT VERIFICATION
    Watt, Sandie
    Vinod, Shalini K.
    Dimigen, Marion
    Descallar, Joseph
    Zogovic, Branimir
    Atyeo, John
    Wallis, Sian
    Holloway, Lois
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S399 - S399
  • [8] Inter-observer variability of clinical target volume delineation in definitive radiotherapy of neck lymph node metastases from unknown primary. A cooperative study of the Italian Association of Radiotherapy and Clinical Oncology (AIRO) Head and Neck Group
    Trignani, Marianna
    Argenone, Angela
    Di Biase, Saide
    Musio, Daniela
    Merlotti, Anna
    Ursino, Stefano
    Orlandi, Ester
    Genovesi, Domenico
    Bacigalupo, Almalina
    RADIOLOGIA MEDICA, 2019, 124 (07): : 682 - 692
  • [9] Inter-observer variability of clinical target volume delineation in definitive radiotherapy of neck lymph node metastases from unknown primary. A cooperative study of the Italian Association of Radiotherapy and Clinical Oncology (AIRO) Head and Neck Group
    Marianna Trignani
    Angela Argenone
    Saide Di Biase
    Daniela Musio
    Anna Merlotti
    Stefano Ursino
    Ester Orlandi
    Domenico Genovesi
    Almalina Bacigalupo
    La radiologia medica, 2019, 124 : 682 - 692
  • [10] Reducing the dose of gadolinium-based contrast agents for DCE-MRI guided SBRT: The effects on inter and intra observer variability for preoperative target volume delineation in early stage breast cancer patients
    Mouawad, Matthew
    Biernaski, Heather
    Brackstone, Muriel
    Lock, Michael
    Yaremko, Brian
    Sexton, Tracy
    Yu, Edward
    Dinniwell, Robert E.
    Lynn, Kalan
    Hajdok, George
    Prato, Frank S.
    Thompson, Robert Terry
    Gelman, Neil
    Gaede, Stewart
    RADIOTHERAPY AND ONCOLOGY, 2019, 131 : 60 - 65