The effect of unrealistic thyroid vertical position on thyroid dose in the MIRD phantom

被引:8
|
作者
Lee, C
Lee, J
Lee, C
机构
[1] Hanyang Univ, Innovat Technol Ctr Radiat Safety, Seoul 133791, South Korea
[2] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
关键词
D O I
10.1118/1.1764702
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Anatomically, the thyroid gland is placed in the lower neck, extending from the level of the fifth cervical vertebra down to the first thoracic vertebra. However, the thyroid of the Medical Internal Radiation Dose (MIRD) phantom, which has been widely used for dosimetric calculation, is located right above the top of the torso and is completely included in the neck region. To investigate the effect of the unrealistic position of the thyroid in the MIRD phantom on dose calculation, thyroid absorbed doses at various vertical positions were calculated for the idealized external broad parallel photon beam from anterior-posterior, posterior-anterior, right lateral (RLAT), and left lateral (LLAT) direction using the Monte Carlo method. The thyroid absorbed dose decreased by as much as about 60% for 0.05 MeV photon in both RLAT and LLAT irradiations when the thyroid was relocated to realistic position (inserted into the torso). The effective dose also decreased by 10%, consequently. The thyroid dose of the widely accepted stylized model, the MIRD phantom, is overestimated in RLAT and LLAT irradiation geometries. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:2038 / 2041
页数:4
相关论文
共 50 条
  • [1] Application of a sitting MIRD phantom for effective dose calculations
    Olsher, RH
    Van Riper, KA
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 392 - 395
  • [2] THYROID PHANTOM FOR SCINTILLOGRAPHY
    MAS, FR
    GALLIZZI, MC
    MEDICINA, 1970, 30 (03): : 272 - &
  • [3] Modification of MIRD human phantom based on the comparison of the dose calculation with the realistic voxel phantom.
    Lee, C
    Lee, C
    Lee, J
    HEALTH PHYSICS, 2002, 82 (06): : S121 - S121
  • [4] Effect of leaded glasses and thyroid shielding on cone beam CT radiation dose in an adult female phantom
    Goren, A. D.
    Prins, R. D.
    Dauer, L. T.
    Quinn, B.
    Al-Najjar, A.
    Faber, R. D.
    Patchell, G.
    Branets, I.
    Colosi, D. C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (06)
  • [5] The effect of aging on the anatomic position of the thyroid gland
    Bann, Darrin V.
    Kim, Yesul
    Zacharia, Thomas
    Goldenberg, David
    CLINICAL ANATOMY, 2017, 30 (02) : 205 - 212
  • [6] A SIMPLE RADIOACTIVE-THYROID PHANTOM
    PREUSS, LE
    NUCLEONICS, 1951, 9 (04): : 72 - 74
  • [7] NEW ANSI STANDARD FOR THYROID PHANTOM
    Mallett, Michael W.
    Bolch, Wesley E.
    Fulmer, Philip C.
    Jue, Tracy M.
    McCurdy, David E.
    Pillay, Mike
    Xu, X. George
    HEALTH PHYSICS, 2015, 109 (02): : 177 - 178
  • [8] Impact of smoking on thyroid gland: dose-related effect of urinary cotinine levels on thyroid function and thyroid autoimmunity
    Kim, Su-jin
    Kim, Min Joo
    Yoon, Sang Gab
    Myong, Jun Pyo
    Yu, Hyeong Won
    Chai, Young Jun
    Choi, June Young
    Lee, Kyu Eun
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [9] Impact of smoking on thyroid gland: dose-related effect of urinary cotinine levels on thyroid function and thyroid autoimmunity
    Su-jin Kim
    Min Joo Kim
    Sang Gab Yoon
    Jun Pyo Myong
    Hyeong Won Yu
    Young Jun Chai
    June Young Choi
    Kyu Eun Lee
    Scientific Reports, 9