New fault location scheme for four-circuit untransposed transmission lines

被引:22
作者
Saber, Ahmed [1 ]
机构
[1] Cairo Univ, Elect Power & Machines Dept, Gi, Egypt
关键词
Pour-circuit transmission line; Fault location; Phasor measurement unit (PMU); INFERENCE SYSTEM APPROACH; LIMITED NUMBER; ALGORITHM; CLASSIFICATION; NETWORKS;
D O I
10.1016/j.ijepes.2018.01.006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper introduces a new fault location scheme for two-terminal four-circuit untransposed transmission line using synchronized measurements. The current phasors at both line terminals and the voltage phasor at only one terminal are needed to formulate the fault location equation. The proposed scheme is developed based on theory of transmission lines and expansion of Taylor series for the distributed line model parameters. The mutual coupling between all phases and the untransposition of the line are considered to obtain precise results. The faulty phases are determined using Kirchhoff's current law (KCL) and all fault types including normal shunt and inter-circuit faults can be located. DIgSILENT Power Factory software is used to simulate the power system and the fault location calculations are carried out using MATLAB. The proposed scheme is investigated under different fault locations, fault inception angles, fault types, and fault resistances. The influence of soil resistivity variation, measurement and synchrophasors errors, errors in line parameters, various line lengths, non-linear time-varying arc resistance, and complex fault impedance is also investigated. The simulation results confirm the validity of the fault location scheme for all test cases.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
[11]   Fault Location Method for Untransposed Transmission Lines with Derivations [J].
Di Santo, S. G. ;
Pereira, C. E. M. .
2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
[12]   Fault location method for partial coupling four-circuit overhead lines with different voltages [J].
Saber, Ahmed .
ELECTRICAL ENGINEERING, 2020, 102 (02) :529-538
[13]   Single-Phase Fault Location in Four-Circuit Transmission Lines Based on Wavelet Analysis Using ANFIS [J].
Ali Khaleghi ;
Mahmoud Oukati Sadegh .
Journal of Electrical Engineering & Technology, 2019, 14 :1577-1584
[14]   Fault location method for partial coupling four-circuit overhead lines with different voltages [J].
Ahmed Saber .
Electrical Engineering, 2020, 102 :529-538
[15]   A New Scheme of Fault Location for Parallel Double-circuit Transmission Lines [J].
Chen, Gonggui ;
Cai, Daiying ;
Tang, Bangrui .
2020 CHINESE AUTOMATION CONGRESS (CAC 2020), 2020, :1118-1122
[16]   Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm [J].
Minan Tang ;
Hang Lu ;
Bin Li .
Protection and Control of Modern Power Systems, 2023, 8
[17]   Fault location of untransposed double-circuit transmission lines based on an improved Karrenbauer matrix and the QPSO algorithm [J].
Tang, Minan ;
Lu, Hang ;
Li, Bin .
PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2023, 8 (01)
[18]   A new fault location scheme for parallel transmission lines using one-terminal data [J].
Saber, A. ;
Zeineldin, H. H. ;
EL-Fouly, Tarek H. M. ;
Al-Durra, Ahmed .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 135
[19]   Accurate Fault Location for Untransposed/Transposed Transmission Lines Using Sparse Wide-Area Measurements [J].
Jiao, Xiangqing ;
Liao, Yuan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) :1797-1805
[20]   A New Fault Location Scheme Based on Distribution Parameter for Four-Parallel Transmission Lines on Same Tower [J].
Xu Peng ;
Liang Yuansheng .
POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, :604-+