Design of a Wireless Intraocular Pressure Monitoring System for a Glaucoma Drainage Implant

被引:0
|
作者
Kakaday, T. [1 ]
Plunkett, M. [2 ]
McInnes, S. [3 ]
Li, J. S. Jimmy [1 ]
Voelcker, N. H. [3 ]
Craig, J. E. [4 ]
机构
[1] Flinders Univ S Australia, Sch Comp Sci Engn & Math, Sturt Rd,Bedford Pk, Adelaide, SA 5042, Australia
[2] Ellex Med Lasers R&D, Adelaide, SA, Australia
[3] Flinders Univ S Australia, Sch Chem Phys & Earth Sci, Adelaide, SA, Australia
[4] Flinders Med Ctr, Dept Ophthalmol, Adelaide, SA, Australia
来源
13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3 | 2009年 / 23卷 / 1-3期
关键词
Glaucoma; intraocular pressure; glaucoma drainage implant; micro-electro-mechanical systems (MEMS); and capacitive pressure sensor; SENSOR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Glaucoma is a common cause of blindness. Wireless, continuous monitoring of intraocular pressure (IOP) is an important, unsolved goal in managing glaucoma. An IOP monitoring system incorporated into a glaucoma drainage implant (GDI) overcomes the design complexity with incorporating a similar system in a more confined space within the eye. The device consists of a micro-electro-mechanical systems (MEMS) based capacitive pressure sensor combined with an inductor printed directly onto a polyimide printed circuit board (PCB). The device is designed to be placed onto the external plate of a therapeutic GDI. The resonance frequency changes as a function of IOP and is tracked remotely using a spectrum analyzer. A theoretical model for the reader antenna was developed to enable maximal inductive coupling with the IOP sensor implant, including modeling of high frequency effects. Pressure chamber tests indicate that the device has adequate sensitivity in the IOP range with excellent reproducibility over time. Additionally, we show that sensor sensitivity does not change significantly after encapsulation with polydimethylsiloxane (PDMS) to protect the device from the aqueous environment. In vitro experiments showed that the signal measured wirelessly through sheep corneal tissue was adequate indicating potential for using the system in human subjects.
引用
收藏
页码:198 / +
页数:2
相关论文
共 50 条
  • [1] Development of a wireless intra-ocular pressure monitoring system for incorporation into a therapeutic glaucoma drainage implant
    Kakaday, Tarun
    Plunkett, Malcolm
    McInnes, Steven
    Li, Jim S. Jimmy
    Voelcker, Nicolas H.
    Craig, Jamie E.
    BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING IV AND COMPLEX SYSTEMS, 2008, 7270
  • [2] Design of an Optical Pressure Measurement System for Intraocular Pressure Monitoring
    Phan, Alex
    Phuong Truong
    Trumpp, Julian
    Talke, Frank E.
    IEEE SENSORS JOURNAL, 2018, 18 (01) : 61 - 68
  • [3] Self-monitoring of intraocular pressure in glaucoma
    Beck, Daniel
    Tatham, Andrew J.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2019, 14 (4-5) : 219 - 225
  • [4] A New Design and Application of Bioelastomers for Better Control of Intraocular Pressure in a Glaucoma Drainage Device
    Quang Minh Luong
    Shang, Lei
    Ang, Marcus
    Kong, Jen Fong
    Peng, Yan
    Wong, Tina T.
    Venkatraman, Subbu S.
    ADVANCED HEALTHCARE MATERIALS, 2014, 3 (02) : 205 - 213
  • [5] Design of wireless contact-lens antenna for intraocular pressure monitoring
    Priya, L.
    Vijitha, J.
    Alagappan, M.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2019, 31 (03) : 315 - 323
  • [6] Magnetic Design for an IPT based Wireless Intraocular Pressure Regulating Implant
    Xu, Qing
    Thrimawithana, Duleepa J.
    Svirskis, Darren
    Rupenthal, Ilva Dana
    2017 IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2017, : 525 - 530
  • [7] Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma
    Kim, Tae Yeon
    Mok, Jee Won
    Hong, Sang Hoon
    Jeong, Sang Hoon
    Choi, Hyunsik
    Shin, Sangbaie
    Joo, Choun-Ki
    Hahn, Sei Kwang
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [8] Is 24-hour Intraocular Pressure Monitoring Necessary in Glaucoma?
    Mansouri, Kaweh
    Weinreb, Robert N.
    Medeiros, Felipe A.
    SEMINARS IN OPHTHALMOLOGY, 2013, 28 (03) : 157 - 164
  • [9] A Wireless Handheld Pressure Measurement System for In Vivo Monitoring of Intraocular Pressure in Rabbits
    Phan, Alex
    Truong, Phuong
    Camp, Andrew
    Stewart, Kerrianne
    Suen, Benjamin
    Weinreb, Robert N.
    Talke, Frank E.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (03) : 931 - 937
  • [10] The Ahmed Glaucoma Valve - a new implant for high intraocular pressure
    Hille, K
    Ruprecht, KW
    OPHTHALMOLOGE, 1999, 96 (10): : 653 - 657