A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry

被引:341
作者
Schneider, David [1 ]
Marquardt, Pascal
Zwahlen, Marcel [2 ]
Jung, Ronald E. [1 ]
机构
[1] Univ Zurich, Dept Fixed & Removable Prosthodont & Dent Mat Sci, Sch Dent, CH-8032 Zurich, Switzerland
[2] Univ Bern, Inst Social & Prevent Med, Bern, Switzerland
关键词
computer-guided implant dentistry; dental implants; image-guided surgery; STEREOLITHOGRAPHIC SURGICAL GUIDES; COMPLICATION RATES; PLACEMENT; SURVIVAL; RELIABILITY; TOMOGRAPHY; PROSTHESIS; SURGERY; IMAGES;
D O I
10.1111/j.1600-0501.2009.01788.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry. Materials and methods An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized. Results From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures. Conclusion Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications. To cite this article:Schneider D, Marquardt P, Zwahlen M, Jung RE. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry.Clin. Oral Impl. Res. 20 (Suppl. 4), 2009; 73-86.doi: 10.1111/j.1600-0501.2009.01788.x.
引用
收藏
页码:73 / 86
页数:14
相关论文
共 50 条
  • [21] Accuracy of a flapless protocol for computer-guided zygomatic implant placement in human cadavers: expectations and reality
    Schiroli, Guido
    Angiero, Francesca
    Zangerl, Antoniettel
    Benedicenti, Stefano
    Ferrante, Franco
    Widmann, Gerlig
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (01) : 102 - 108
  • [22] Computer-guided implant surgery and immediate loading with a modifiable radiographic template in a patient with partial edentulism: A clinical report
    Lanis, Alejandro
    Padial-Molina, Miguel
    Gamil, Rami
    del Canto, Orlando Alvarez
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (03) : 328 - 334
  • [23] Accuracy of template-based guided dental implant placement-An in vitro comparison of different manufacturing methods
    Sium-Abel, Aura
    Keilig, Ludger
    Doersam, Istabrak
    Bourauel, Christoph
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 864 - 875
  • [24] Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance
    Naeini, Emitis Natali
    Atashkadeh, Mandana
    De Bruyn, Hugo
    D'Haese, Jan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 454 - 467
  • [25] CLINICAL FACTORS AFFECTING THE ACCURACY OF GUIDED IMPLANT SURGERY-A SYSTEMATIC REVIEW AND META-ANALYSIS
    Zhou, Wenjuan
    Liu, Zhonghao
    Song, Liansheng
    Kuo, Chia-Ling
    Shafer, David M.
    JOURNAL OF EVIDENCE-BASED DENTAL PRACTICE, 2018, 18 (01) : 28 - 40
  • [26] Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement
    Behneke, Alexandra
    Burwinkel, Matthias
    Behneke, Nikolaus
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) : 416 - 423
  • [27] Accuracy of computer-guided implant surgery in partially edentulous patients: a prospective observational study
    Chrabieh, Emile
    Hanna, Christine
    Mrad, Stephanie
    Rameh, Stephanie
    Bassil, Joseph
    Zaarour, Joseph
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2024, 10 (01)
  • [28] The Effects of Distribution of Image Matched Fiducial Markers on Accuracy of Computer-Guided Implant Surgery
    Choi, Yong-Do
    Mai, Hang-Nga
    Mai, Hai Yen
    Ha, Jung-Hong
    Li, Lin-Jie
    Lee, Du-Hyeong
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (05): : 409 - 414
  • [29] Influence of clinical and technical parameters on accuracy of guided implant placement. Systematic review and meta-analysis
    Kasradze, D.
    Segalyte, E.
    Kubilius, R.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (04) : 198 - 219
  • [30] Comparison between computer-guided and freehand dental implant placement surgery: A systematic review and meta-analysis
    Yogui, F. C.
    Verri, F. R.
    Gomes, J. M. de Luna
    Lemos, C. A. A.
    Cruz, R. S.
    Pellizzer, E. P.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (02) : 242 - 250