A field evaluation of the predictive value of a hand-held drum pressure detection device

被引:0
作者
Pannell, MA
Brandt, MT
Boatright, DT
机构
[1] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[2] Univ Oklahoma, Hlth Sci Ctr, Oklahoma City, OK 73190 USA
关键词
acoustic resonance spectroscopy; drum pressure prediction; drum pressurization;
D O I
10.1080/15459620490445480
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
According to Environmental Protection Agency estimates, 20% of hazardous waste drums currently managed in the 6500 known, uncontrolled Superfund removal or remediation sites contain some degree of elevated internal pressurization. This estimate increases to 90% during the summer months, and, overall, tip to 5% of the drums stored in active treatment, storage, and disposal facilities may be pressurized. The ability to identify pressurized drums in real-time would enhance worker health and safety, reduce the potential for environmental contamination, and minimize property damage. A prototype hand-held drum pressure detection device was field tested at all active Resource Conservation and Recovery Act mixed waste operation using acoustic resonance spectroscopy technology to identify pressurized drums. The waste operation used a drum venting system that measured the actual drum pressure of retrieved drums. Drum venting system data were analyzed to quantify the ability of the drum pressure detection device to correctly identify drums with elevated internal pressure. After 456 drums were measured, the dichotomous pressure data (pressurized vs. nonpressurized) were analyzed. The relationship between the drum venting system and drum pressure detection device pressure data was found to be statistically significant. With alpha and beta values of 0.05, the negative predictive value was 0.94, the positive predictive value was 0.47, the sensitivity was 0.82, and the specificity was 0.77. Although capable of identifying nonpressurized drums, this instrument may not be appropriate for general use. Study results and critical improvements necessary to improve the instrument's predictive value, specificity, and sensitivity are presented.
引用
收藏
页码:319 / 323
页数:5
相关论文
共 8 条
[1]  
*DOE, 1993, FIR EXPL HIGH PRESS
[2]  
LAFORNARA J, 1999, COMMUNICATION
[3]  
LARRANAGA MD, 1998, PRESSURE EFFECTS DEF
[4]  
PANNELL MA, 1999, AM IND HYG C TOR JUN
[5]  
PANNELL MA, 1999, THESIS U OKLAHOMA HL
[6]  
PATEL H, 1998, REV PROGR QUANT NOND
[7]  
SINHA DN, 1994, MAT RES SOC S P, V333
[8]  
*THINNES GL, 1995, RESONANCE ANAL DETER