Using Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty Necessitating 44-or46-mm Metal Shells

被引:0
作者
Park, Chan Ho [1 ]
Ha, Yong-Chan [2 ]
Lee, Young-Kyun [3 ]
Koo, Kyung-Hoi [3 ]
机构
[1] Yeungnam Univ, Med Ctr, Dept Orthopaed Surg, Daegu, South Korea
[2] Chung Ang Univ, Coll Med, Dept Orthopaed Surg, Seoul, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Orthopaed Surg, 82 Gumi Ro,173 Beon Gil, Seongnam 13620, Gyeonggi Do, South Korea
关键词
CROSS-LINKED POLYETHYLENE; ACETABULAR COMPONENT; LATERAL APPROACH; FEMORAL-HEAD; WEAR; DISLOCATION; REPLACEMENT; FRACTURES; DYSPLASIA; FREQUENCY;
D O I
10.3928/01477447-20180320-01
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Ceramic-on-ceramic articulation shows the lowest wear, with a low incidence of osteolysis. A small cup limits options regarding liner thickness and femoral implant size. The purpose of this study was to evaluate the safety of a 4-mm-thick ceramic liner and the outcomes of cementless total hip arthroplasty using a 44-or 46-mm metal shell and a ceramic-on-ceramic bearing at mid-to long-term follow-up. Between May 2003 and June 2008, 80 patients (88 hips) who had hip osteoarthritis and a hypoplastic acetabulum underwent cementless total hip arthroplasty using a 44-or 46-mm metal shell and a ceramic-on-ceramic bearing. Sixty-eight of these patients (76 hips) were followed for an average of 8 years. The ceramic-related complications, clinical and radiological results, and Kaplan-Meier survivorship of these patients were evaluated. Mean Harris hip score had improved to 88 points (range, 49-100 points) at final follow-up. No ceramic fractures occurred during follow-up. All acetabular and femoral prostheses had bone ingrowth, and there was no measurable wear in any hip. In 1 patient, a radiolucent lesion occurred around the acetabular cup. Two hips underwent revision because of periprosthetic fractures. The survival rates of the acetabular cups and the femoral stems were 100% and 97.4%, respectively. The thin (4 mm) ceramic liner did not increase the risk of ceramic fracture and did not affect the mid-to long-term results and survival of cementless total hip arthroplasty using 44-or 46-mm metal shells.
引用
收藏
页码:E354 / E359
页数:6
相关论文
共 28 条
  • [1] Total hip arthroplasty with insertion of the acetabular component without cement in hips with total congenital dislocation or marked congenital dysplasia
    Anderson, MJ
    Harris, WH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (03) : 347 - 354
  • [2] CATASTROPHIC FAILURE OF THE POLYETHYLENE LINER OF UNCEMENTED ACETABULAR COMPONENTS
    BERRY, DJ
    BARNES, CL
    SCOTT, RD
    CABANELA, ME
    POSS, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04): : 575 - 578
  • [3] ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION
    BROOKER, AF
    BOWERMAN, JW
    ROBINSON, RA
    RILEY, LH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) : 1629 - 1632
  • [4] Total hip arthroplasty in patients with deficient bone stock and small femoral canals
    Cameron, HU
    Lee, OB
    Chou, H
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (01) : 35 - 40
  • [5] Total hip replacement using a highly cross-linked polyethylene liner in Asians with small acetabulum
    Chua, Weiliang
    Roy, Shuvendu
    Sng, Jonathan
    Liang, Shen
    Das De, Shamal
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03): : 342 - 346
  • [6] DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
  • [7] ENGH CA, 1994, CLIN ORTHOP RELAT R, P89
  • [8] ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
  • [9] The evolution of an uncemented acetabular component in alumina-on-alumina total hip arthroplasty has improved clinical outcome A PROSPECTIVE, COMPARATIVE FIVE- TO 15-YEAR FOLLOW-UP STUDY
    Garcia-Rey, E.
    Cruz-Pardos, A.
    Garcia-Cimbrelo, E.
    [J]. BONE & JOINT JOURNAL, 2017, 99B (06) : 749 - 758
  • [10] The influence of head diameter and wall thickness on deformations of metallic acetabular press-fit cups and UHMWPE liners: a finite element analysis
    Goebel, Paul
    Kluess, Daniel
    Wieding, Jan
    Souffrant, Robert
    Heyer, Horst
    Sander, Manuela
    Bader, Rainer
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (02) : 264 - 270