Cytochrome P450 2D6 based electrochemical sensor for the determination of codeine

被引:21
作者
Asturias-Arribas, Laura [1 ]
Asuncion Alonso-Lomillo, M. [1 ]
Dominguez-Renedo, Olga [1 ]
Julia Arcos-Martinez, M. [1 ]
机构
[1] Univ Burgos, Fac Sci, Dept Analyt Chem, Burgos 09001, Spain
关键词
Codeine; Cytochrome P450 2D6; Screen-printed electrode; Biosensor; VOLTAMMETRIC DETERMINATION; ALUMINUM ELECTRODE; CARBON ELECTRODES; ASCORBIC-ACID; MORPHINE; BIOSENSORS; DRUGS; PHARMACEUTICALS; PARACETAMOL; METABOLITES;
D O I
10.1016/j.talanta.2014.05.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Considering the enzymatic activity of the cytochrome P450 2D6 on substrates such as codeine, the current paper includes the development of an enzymatic biosensor for detection of this drug. Home-made screen-printed electrodes were used as electrochemical transducers of the biosensor, in which the enzyme was covalently attached to the carbon surface of the working electrode, this type of modification being the most suitable for the immobilization of the biological element. Chronoamperometric measurements were carried out under optimum conditions of pH and working potential, pH 7 and +200 mV vs. screen-printed Ag/AgCl electrode, giving a reduction signal related to the concentration of codeine in solution. Consecutive additions of a solution of codeine were performed to obtain calibration curves in order to validate the electrochemical method in terms of precision and calculate its capability of detection. These biosensors were used for the determination of codeine in urine and commercial pharmaceutical samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:315 / 319
页数:5
相关论文
共 42 条
[1]   CYP450 biosensors based on gold chips for antiepileptic drugs determination [J].
Alonso-Lomillo, M. A. ;
Gonzalo-Ruiz, J. ;
Dominguez-Renedo, O. ;
Munoz, F. J. ;
Arcos-Martinez, M. J. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (11) :1733-1737
[2]   CYP450 2B4 covalently attached to carbon and gold screen printed electrodes by diazonium salt and thiols monolayers [J].
Alonso-Lomillo, M. A. ;
Yardimci, C. ;
Dominguez-Renedo, O. ;
Arcos-Martinez, M. J. .
ANALYTICA CHIMICA ACTA, 2009, 633 (01) :51-56
[3]  
[Anonymous], 1994, STATGRAPHICS
[4]   Screen-printed biosensor based on the inhibition of the acetylcholinesterase activity for the determination of codeine [J].
Asturias-Arribas, Laura ;
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Julia Arcos-Martinez, M. .
TALANTA, 2013, 111 :8-12
[5]   Electrochemical determination of cocaine using screen-printed cytochrome P450 2B4 based biosensors [J].
Asturias-Arribas, Laura ;
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Julia Arcos-Martinez, M. .
TALANTA, 2013, 105 :131-134
[6]   CYP450 biosensors based on screen-printed carbon electrodes for the determination of cocaine [J].
Asturias-Arribas, Laura ;
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Julia Arcos-Martinez, M. .
ANALYTICA CHIMICA ACTA, 2011, 685 (01) :15-20
[7]   Sensitive enzyme-biosensor based on screen-printed electrodes for Ochratoxin A [J].
Asuncion Alonso-Lomillo, M. ;
Dominguez-Renedo, Olga ;
Ferreira-Goncalves, Liliana ;
Julia Arcos-Martinez, M. .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (06) :1333-1337
[8]   New enzyme sensors for morphine and codeine based on morphine dehydrogenase and laccase [J].
Bauer, CG ;
Kühn, A ;
Gajovic, N ;
Skorobogatko, O ;
Holt, PJ ;
Bruce, NC ;
Makower, AA ;
Lowe, CR ;
Scheller, FW .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (1-2) :179-183
[9]   ANODIC VOLTAMMETRY OF CODEINE AND DIHYDROCODEINE AT ROTATING-DISK ELECTRODES OF PLATINUM AND GOLD [J].
BISHOP, E ;
HUSSEIN, W .
ANALYST, 1984, 109 (02) :143-145
[10]   Cytochrome P450 biosensors - a review [J].
Bistolas, N ;
Wollenberger, U ;
Jung, C ;
Scheller, FW .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2408-2423