Calculating the predicted retinal thickness from spectral domain and time domain optical coherence tomography - comparison of different methods

被引:9
作者
Tan, Colin S. [1 ,2 ]
Li, Kelvin Z. [1 ]
Lim, Tock Han [1 ,2 ]
机构
[1] Tan Tock Seng Hosp, Dept Ophthalmol, Singapore 308433, Singapore
[2] Natl Healthcare Grp Eye Inst, Fundus Image Reading Ctr, Singapore, Singapore
关键词
Optical coherence tomography; Central retinal thickness; Spectral domain OCT; Time domain OCT; DIABETIC MACULAR EDEMA; NORMAL EYES; STRATUS OCT; INSTRUMENTS; DEGENERATION; RANIBIZUMAB; BOUNDARY; ADULTS;
D O I
10.1007/s00417-014-2672-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare the accuracy of different methods of calculating predicted central retinal thickness values in order to allow comparison between results of spectral-domain optical coherence tomography (SD-OCT) and time-domain OCT (TD-OCT) devices. In a prospective cohort study, 100 consecutive healthy individuals without ocular disease underwent sequential scanning with SD-OCT (Spectralis OCT) and TD-OCT (Stratus OCT). A group of 60 eyes was used to generate the conversion equations, which were tested on the remaining 140 eyes. Four equations were used: 1. Mean difference between SD-OCT and TD-OCT; 2. Multiplying a ratio by the original retinal thickness; 3. Linear regression analysis using retinal thickness; and 4. Regression analysis using retinal thickness and spherical equivalent. All four methods were used to calculate predicted SD-OCT values from TD-OCT measurements, and vice versa. For all four equations, the predicted SD-OCT central retinal thickness values were similar to the actual SD-OCT, with mean difference ranging from 0.78 to 1.01 mu m, and intraclass correlation coefficients > 0.88. Both regression equations and mean difference showed greater accuracy, with variation between calculated and actual retinal thickness values a parts per thousand currency sign5 mu m in 60 % of eyes. In contrast, the ratio method was less accurate, with 15.8 % of eyes showing differences > 15 mu m. Similar results were found for predicted TD-OCT values. Several methods can be used to convert central retinal thickness values from SD-OCT to the predicted TD-OCT value, or vice versa, with high degrees of accuracy and reliability. These methods may allow comparison of OCT values from SD-OCT and TD-OCT devices in clinical trials and standard patient care.
引用
收藏
页码:1491 / 1499
页数:9
相关论文
共 28 条
  • [1] Correlation in foveal thickness measurements between spectral-domain and time-domain optical coherence tomography in normal individuals
    Carpineto, P.
    Nubile, M.
    Toto, L.
    Gnama, A. Aharrh
    Marcucci, L.
    Mastropasqua, L.
    Ciancaglini, M.
    [J]. EYE, 2010, 24 (02) : 251 - 258
  • [2] Ranibizumab versus Bevacizumab to Treat Neovascular Age-related Macular Degeneration
    Chakravarthy, Usha
    Harding, Simon P.
    Rogers, Chris A.
    Downes, Susan M.
    Lotery, Andrew J.
    Wordsworth, Sarah
    Reeves, Barnaby C.
    [J]. OPHTHALMOLOGY, 2012, 119 (07) : 1399 - 1411
  • [3] Comparison of Central Retinal Thickness in Healthy Children and Adults Measured with the Heidelberg Spectralis OCT and the Zeiss Stratus OCT 3
    Chopovska, Yaroslava
    Jaeger, Melanie
    Rambow, Ronny
    Lorenz, Birgit
    [J]. OPHTHALMOLOGICA, 2011, 225 (01) : 27 - 36
  • [4] Repeatability of Spectralis OCT Measurements of Macular Thickness and Volume in Diabetic Macular Edema
    Comyn, Oliver
    Heng, Ling Zhi
    Ikeji, Felicia
    Bibi, Kanom
    Hykin, Philip G.
    Bainbridge, James W.
    Patel, Praveen J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (12) : 7754 - 7759
  • [5] Optical coherence tomography 3: Delineation of the outer neural retinal boundary and its influence on retinal thickness measurements
    Costa, RA
    Calucci, D
    Skaf, M
    Cardillo, JA
    Castro, JC
    Melo, LA
    Martins, MC
    Kaiser, PK
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (07) : 2399 - 2406
  • [6] Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema
    Forooghian, Farzin
    Cukras, Catherine
    Meyerle, Catherine B.
    Chew, Emily Y.
    Wong, Wai T.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) : 4290 - 4296
  • [7] Comparison of time domain Stratus OCT and spectral domain SLO/OCT for assessment of macular thickness and volume
    Forte, R.
    Cennamo, G. L.
    Finelli, M. L.
    de Crecchio, G.
    [J]. EYE, 2009, 23 (11) : 2071 - 2078
  • [8] An optical coherence tomography-guided, variable dosing regimen with intravitreal ranibizumab (lucentis) for neovascular age-related macular degeneration
    Fung, Anne E.
    Lalwani, Geeta A.
    Rosenfeld, Philip J.
    Dubovy, Sander R.
    Michels, Stephan
    Feuer, William J.
    Puliafito, Carmen A.
    Davis, Janet L.
    Flynn, Harry W., Jr.
    Esquiabro, Maria
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (04) : 566 - 583
  • [9] Reproducibility of Retinal Thickness Measurements on Normal and Pathologic Eyes by Different Optical Coherence Tomography Instruments
    Giani, Andrea
    Cigada, Mario
    Choudhry, Netan
    Deiro, Antonio Peroglio
    Oldani, Marta
    Pellegrini, Marco
    Invernizzi, Alessandro
    Duca, Piergiorgio
    Miller, Joan W.
    Staurenghi, Giovanni
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (06) : 815 - 824
  • [10] Comparison of Retinal Thickness in Normal Eyes Using Stratus and Spectralis Optical Coherence Tomography
    Grover, Sandeep
    Murthy, Ravi K.
    Brar, Vikram S.
    Chalam, Kakarla V.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) : 2644 - 2647