Home Blood Pressure Monitoring: A Few minutes of Rest Before Measurement May Not Be Appropriate

被引:8
作者
Boivin, Jean-Marc [1 ,2 ,3 ]
Boutte, Emilie [1 ,2 ]
Fay, Renaud [3 ]
Rossignol, Patrick [1 ,3 ]
Zannad, Faiez [1 ,3 ]
机构
[1] Lorraine Univ, Nancy, France
[2] Fac Med, Dept Family Med, Nancy, France
[3] CHU Pierre Drouin, INSERM, CIC P, Nancy, France
关键词
blood pressure; home blood pressure measurement; hypertension; hypertension measurement; TENSOVAL DUO CONTROL; EUROPEAN-SOCIETY; SELF-MEASUREMENT; HYPERTENSION GUIDELINES; CARDIOVASCULAR EVENTS; DIAGNOSIS; BRITISH; ADULTS;
D O I
10.1093/ajh/hpu001
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND Home blood pressure measurement (HBPM) is recommended for the diagnosis and follow-up of hypertensive patients. While measurement protocols emphasize a rest period before taking the measurement, this directive has not been supported by any specific study to date. This analysis aimed to determine whether the respect or non-respect of rest before HBPM could introduce a difference between daytime ambulatory blood pressure measurement (ABPM) and HBPM; whether this rest is observed "in real life" among educated hypertensive patients. METHODS In this open, prospective study we compared HBPM, with and without rest, and ABPM among 52 office/clinically controlled hypertensive patients. HBPM was performed during 3 days (French HAS instructions); 24-hour ABPM was performed within 3 days of HBPM. All patients who regularly performed HBPM before the study were asked how they practiced HBPM in real life. RESULTS There was a differential impact of rest on differences observed in daytime ABPM and HBPM. Systolic HBPM decreased with rest, while diastolic HBPM did not significantly increase. HBPM systolic BP (SBP) without rest was not significantly different from daytime ABPM SBP (P = 0.27). HBPM SBP without rest was lower than daytime and 24-hour systolic ABPM. Diastolic HBPM after rest was not significantly different from daytime diastolic ABPM (P = 0.09). None of the 38 patients who regularly performed HBPM were compliant with a period of rest before beginning the measurements. CONCLUSIONS Rest before HBPM induces a bias that underestimates SBP vs. daytime ABPM and perhaps complicates patient adherence to HBPM protocols.
引用
收藏
页码:932 / 938
页数:7
相关论文
共 35 条
[1]   Blood pressure recordings within and outside the clinic and cardiovascular events in chronic kidney disease [J].
Agarwal, Rajiv ;
Andersen, Martin J. .
AMERICAN JOURNAL OF NEPHROLOGY, 2006, 26 (05) :503-510
[2]   Management of hypertension in adults: the 2013 French Society of Hypertension guidelines [J].
Blacher, Jacques ;
Halimi, Jean-Michel ;
Hanon, Olivier ;
Mourad, Jean-Jacques ;
Pathak, Atul ;
Schnebert, Bruno ;
Girerd, Xavier .
FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2014, 28 (01) :1-9
[3]   Cardiovascular prognosis of "masked hypertension" detected by blood pressure self-measurement in elderly treated hypertensive patients [J].
Bobrie, G ;
Chatellier, G ;
Genes, N ;
Clerson, P ;
Vaur, L ;
Vaisse, L ;
Menard, J ;
Mallion, JM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (11) :1342-1349
[4]   Accuracy assessment of the Tensoval duo control according to the British and European Hypertension Societies' standards [J].
De Greeff, Annemarie ;
Arora, Jasleen ;
Hervey, Simon ;
Liu, Bing ;
Shennan, Andrew H. .
BLOOD PRESSURE MONITORING, 2008, 13 (02) :111-116
[5]   Validation of the Tensoval Duo Control II blood pressure monitor for clinic use and self-measurement according to the British Hypertension Society protocol and the European Society of Hypertension International Protocol revision 2010 [J].
de Greeff, Annemarie ;
Shennan, Andrew H. .
BLOOD PRESSURE MONITORING, 2013, 18 (03) :161-166
[6]   What is the optimal interval between successive home blood pressure readings using an automated oscillometric device? [J].
Eguchi, Kazuo ;
Kuruvilla, Sujith ;
Ogedegbe, Gbenga ;
Gerin, William ;
Schwartz, Joseph E. ;
Pickering, Thomas G. .
JOURNAL OF HYPERTENSION, 2009, 27 (06) :1172-1177
[7]   Prevention of dementia in randomised double-blind placebo-controlled Systolic Hypertension in Europe (Syst-Eur) trial [J].
Forette, F ;
Seux, ML ;
Staessen, JA ;
Thijs, L ;
Birkenhäger, WH ;
Babarskiene, MR ;
Babeanu, S ;
Bossini, A ;
Gil-Extremera, B ;
Girerd, X ;
Laks, T ;
Lilov, E ;
Moisseyev, V ;
Tuomilehto, J ;
Vanhanen, H ;
Webster, J ;
Yodfat, Y ;
Fagard, R .
LANCET, 1998, 352 (9137) :1347-1351
[8]  
HAS, PRIS CHARG PAT ADU A
[9]  
HAS, PRIS CHARG PAT AD AT
[10]   Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study [J].
Head, Geoffrey A. ;
Mihailidou, Anastasia S. ;
Duggan, Karen A. ;
Beilin, Lawrence J. ;
Berry, Narelle ;
Brown, Mark A. ;
Bune, Alex J. ;
Cowley, Diane ;
Chalmers, John P. ;
Howe, Peter R. C. ;
Hodgson, Jonathan ;
Ludbrook, John ;
Mangoni, Arduino A. ;
McGrath, Barry P. ;
Nelson, Mark R. ;
Sharman, James E. ;
Stowasser, Michael .
BMJ-BRITISH MEDICAL JOURNAL, 2010, 340 :849