Comparison of the Bactec 9240 and BacT/Alert Blood Culture Systems for Evaluation of Placental Cord Blood for Transfusion in Neonates

被引:15
作者
Riedel, Stefan [1 ]
Junkins, Alan [2 ]
Stamper, Paul D.
Cress, Gretchen [3 ]
Widness, John A. [3 ]
Doern, Gary V. [2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Pathol, Div Microbiol,Johns Hopkins Bayview Med Ctr, Baltimore, MD 21224 USA
[2] Univ Iowa, Dept Pathol, Div Microbiol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Pediat, Div Neonatol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
AUTOLOGOUS BLOOD; UNITED-STATES; CONTAMINATION; COLLECTION; TRANSPLANTATION; STERILITY; PRODUCTS; THERAPY; STORAGE; SAFETY;
D O I
10.1128/JCM.00302-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The Bactec 9240 and the BacT/Alert blood culture systems were compared as a means for detection of bacterial contaminants in whole blood, concentrated red cells, and plasma preparations prepared from umbilical cord blood (UCB) samples. Ninety-two UCB units seeded with low levels of various bacteria were evaluated. In more than 50% of cases, growth was not detected in plasma using either system (P < 0.001). When concentrated red cells and whole blood were compared, the Bactec system detected bacterial growth consistently sooner than the BacT/Alert system in all seeded bacteria except Staphylococcus species in whole blood. The median lengths of time to detection (LTD) for whole blood and concentrated cells in BacT/Alert were 18.7 h and 18.5 h, respectively. The median LTD for the same blood fractions using the Bactec system were 16.05 h and 15.64 h. These differences in LTD by blood culture system and sample type were statistically significant (whole blood, P = 0.0449; concentrated cells, P = 0.0037). Based on the results of our study, we recommend the use of either concentrated red cells or whole blood for sterility testing in UCB samples. In our laboratory, the Bactec system compared to the BacT/Alert system was the superior method for rapid detection of bacterial contaminants in cord blood.
引用
收藏
页码:1645 / 1649
页数:5
相关论文
共 30 条
  • [1] *AM ASS BLOOD BANK, 2004, STAND CELL THER PROD
  • [2] *AM ASS BLOOD BANK, 2005, TECHN MAN
  • [3] RETRIEVAL OF PLACENTAL BLOOD FROM THE UMBILICAL VEIN TO DETERMINE VOLUME, STERILITY, AND PRESENCE OF CLOT FORMATION
    ANDERSON, S
    FANGMAN, J
    WAGER, G
    UDEN, D
    [J]. AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1992, 146 (01): : 36 - 39
  • [4] Safety of the blood supply in the United States: Opportunities and controversies
    AuBuchon, JP
    Birkmeyer, JD
    Busch, MP
    [J]. ANNALS OF INTERNAL MEDICINE, 1997, 127 (10) : 904 - 909
  • [5] AUTOLOGOUS UMBILICAL-CORD BLOOD-TRANSFUSION
    BALLIN, A
    ARBEL, E
    KENET, G
    BERAR, M
    KOHELET, D
    TANAY, A
    ZAKUT, H
    MEYTES, D
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1995, 73 (03): : F181 - F183
  • [6] COLLECTION AND 28-DAY STORAGE OF HUMAN PLACENTAL BLOOD
    BIFANO, EM
    DRACKER, RA
    LORAH, K
    PALIT, A
    [J]. PEDIATRIC RESEARCH, 1994, 36 (01) : 90 - 94
  • [7] A modified cord blood collection method achieves sufficient cell levels for transplantation in most adult patients
    Bornstein, R
    Flores, AI
    Montalbán, MA
    del Rey, MJ
    de la Serna, J
    Gilsanz, F
    [J]. STEM CELLS, 2005, 23 (03) : 324 - 334
  • [8] Bacterial contamination of blood components
    Brecher, ME
    Hay, SN
    [J]. CLINICAL MICROBIOLOGY REVIEWS, 2005, 18 (01) : 195 - +
  • [9] Autologous placental blood transfusion for a therapy of anaemic neonates
    Brune, T
    Garritsen, H
    Witteler, R
    Schlake, A
    Wüllenweber, J
    Louwen, F
    Jorch, G
    Harms, E
    [J]. BIOLOGY OF THE NEONATE, 2002, 81 (04): : 236 - 243
  • [10] Cord blood as a source of autologous RBCs for transfusion to preterm infants
    Eichler, H
    Schaible, T
    Richter, E
    Zieger, W
    Voller, K
    Leveringhaus, A
    Goldmann, SF
    [J]. TRANSFUSION, 2000, 40 (09) : 1111 - 1117