A Simple RF Attenuation Measurement Technique With a Small Mismatch Uncertainty

被引:3
作者
Widarta, Anton [1 ]
Kawakami, Tomoteru [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058563, Japan
关键词
Attenuation measurement; attenuators; microwave circuit; mismatch; standard;
D O I
10.1109/TIM.2008.2008472
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An accurate radio frequency (RF) and microwave attenuation measurement method is described, where source and load do not have to be matched to the line impedance and where the contribution of a mismatch effect to the uncertainty is reduced to about 0.002 dB. From loss measurements carried out for variable attenuators, as well as for atternuators of fixed attenuation values as devices under test, which are fitted to quarter-wavelength lines in three different configurations, the attenuation is simply obtained and is unrelated to the source and load reflection coefficients of Gamma(G) and Gamma(L), respectively. Experimental results on a 10-dB step attenuator measurement at frequencies from 1 to 17 GHz show good agreement with measurements where the source and load are impedance matched. The technique is effective even with Gamma(G) and Gamma(L) higher than 0.1.
引用
收藏
页码:1164 / 1169
页数:6
相关论文
共 8 条
[1]  
BEATTY RW, 1973, NBS MONOGRAPH, V137
[2]  
FANTOM A, 1990, RADIO FREQUENCY MICR, pCH11
[3]  
HARRIS IA, 1981, P I ELECT ENG H, V128, P35
[4]  
Mason S.J., 1960, ELECT CIRCUITS SIGNA
[5]  
Warner F. L., 1977, IEE MONOGRAPH SERIES, V19
[6]   RECENT IMPROVEMENTS TO THE UK NATIONAL MICROWAVE ATTENUATION STANDARDS [J].
WARNER, FL ;
HERMAN, P ;
CUMMINGS, P .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (01) :33-37
[7]  
WIDARTA A, 2008, P ICEE OK JAP JUL L
[8]  
WIDARTA A, 2008, CPEM BROOMF CO JUN 8, P432