Respiration Average CT for Myocardial Perfusion SPECT/CT Attenuation Correction

被引:0
|
作者
Mok, Greta S. P. [1 ]
Zhang, Duo [1 ]
Ho, Cobie Y. T. [1 ]
机构
[1] Univ Macau, Fac Sci & Technol, Dept Elect & Comp Engn, Macau, Peoples R China
关键词
MISREGISTRATION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Previously we proposed interpolated averaged CT (IACT) as a low dose alternate of cine average CT (CACT) for improved PET/CT attenuation correction (AC) in oncology and cardiology applications. This study aims to evaluate the effectiveness of both average CT protocols in myocardial perfusion SPECT/CT. We simulated a patient injected with Tc-99m-sestamibi using the digital 4D Extended Cardiac Torso (XCAT) phantom. We modeled the respiratory motion of 2, 3 and 4 cm with period of 5.9 s. The average attenuation and activity maps represented CACT and static SPECT, while the attenuation maps of end-inspiration and end-expiration represented 2 helical CTs (HCT-in and HCT-ex). The IACT was obtained by averaging the HCT-in, HCT-ex and the interpolated phases between them generated by B-spline method. Sixty noise free and realistic noisy projections with attenuation modeling were generated from RAO to LPO positions using an analytical projector to model a low energy high resolution parallel-hole collimator. Data were reconstructed with different AC maps (CACT, HCTs and IACT) using OS-EM method with up to 200 updates. Polar plots were generated from the short-axis images and 17-segments were drawn on the plots. Relative difference (RD) of the average intensity was computed for each segment using the original phantom as the reference. Slight artifacts can be observed in the reconstructed images and polar plots using the HCTs AC. For motion amplitude = 2 cm, the maximum RD for CACT, IACT, HCT-in and HCT-ex were 0.7%, 2.3%, 6.1% and 8.0% respectively. The RD of the HCTs notably deviated from the phantom in the basal inferolateral and anterolateral regions especially for higher motion amplitudes. Our findings are consistent with our former results of cardiac PET/CT. We conclude that CACT and IACT have the potential to reduce respiratory artifacts and improve quantitation in myocardial perfusion SPECT/CT. The performance of IACT was comparable to CACT with reduced radiation dose.
引用
收藏
页数:2
相关论文
共 50 条
  • [41] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Goetze, Sibyll
    Wahl, Richard L.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (02) : 200 - 206
  • [42] The impact of attenuation correction in SPECT/CT on quantitative parameters of myocardial perfusion in patients with intact coronary arteries
    Khachirova, E.
    Samoylenko, L.
    Shevchenko, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S562 - S562
  • [43] Optimisation of protocol for low dose CT-derived attenuation correction in myocardial perfusion SPECT imaging
    Preuss, Rainer
    Weise, Reiner
    Lindner, Oliver
    Fricke, Eva
    Fricke, Harald
    Burchert, Wolfgang
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) : 1133 - 1141
  • [44] Optimisation of protocol for low dose CT-derived attenuation correction in myocardial perfusion SPECT imaging
    Rainer Preuss
    Reiner Weise
    Oliver Lindner
    Eva Fricke
    Harald Fricke
    Wolfgang Burchert
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35
  • [45] Attenuation correction of myocardial SPECT perfusion images with low-dose CT: Evaluation of the method by comparison with perfusion PET
    Fricke, E
    Fricke, H
    Weise, R
    Kammeier, A
    Hagedorn, R
    Lotz, N
    Lindner, O
    Tschoepe, D
    Burchert, W
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (05) : 736 - 744
  • [46] Diagnostic impact of CT attenuation correction on CZT myocardial perfusion SPECT in patients with coronary artery disease compared to cardiac SPECT/CT hybrid imaging
    Fukushima, Y.
    Kumita, S.
    Hashimoto, H.
    Sugihara, Y.
    Iwata, K.
    Hamana, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S558 - S558
  • [47] Attenuation correction of thallium myocardial perfusion SPECT
    Ryan, PJ
    Hausenlot, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1232 - 1232
  • [48] CT Attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner
    Koepfli, P
    Hany, TF
    Wyss, CA
    Namdar, M
    Burger, C
    Konstantinidis, AV
    Berthold, T
    von Schulthess, GK
    Kaufmann, PA
    JOURNAL OF NUCLEAR MEDICINE, 2004, 45 (04) : 537 - 542
  • [49] Reducing CT dose in myocardial perfusion SPECT/CT
    O'Shaughnessy, Emma
    Dixon, Kat L.
    NUCLEAR MEDICINE COMMUNICATIONS, 2015, 36 (11) : 1150 - 1154
  • [50] Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECT
    Bhupinder Singh
    Timothy M. Bateman
    James A. Case
    Gary Heller
    Journal of Nuclear Cardiology, 2007, 14