COMPARISON OF SPINE, CARINA, AND TUMOR AS REGISTRATION LANDMARKS FOR VOLUMETRIC IMAGE-GUIDED LUNG RADIOTHERAPY

被引:49
作者
Higgins, Jane [1 ,3 ]
Bezjak, Andrea [1 ,3 ]
Franks, Kevin [4 ]
Le, Lisa W. [2 ,3 ]
Cho, B. C. [1 ,3 ]
Payne, David [1 ,3 ]
Bissonnette, Jean-Pierre [1 ,3 ]
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
[2] Princess Margaret Hosp, Dept Biostat, Toronto, ON M5G 2M9, Canada
[3] Univ Toronto, Toronto, ON, Canada
[4] Leeds Teaching Hosp, St James Inst Oncol, Natl Hlth Serv Trust, Leeds, W Yorkshire, England
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2009年 / 73卷 / 05期
关键词
Lung cancer; Lung radiotherapy; Cone-beam computed tomography; CBCT; Treatment verification; Image-guided radiotherapy; BEAM COMPUTED-TOMOGRAPHY; INTENSITY-MODULATED RADIOTHERAPY; IMPLANTED FIDUCIAL MARKERS; RADIATION-THERAPY; STEREOTACTIC RADIOTHERAPY; HELICAL TOMOTHERAPY; GATED RADIOTHERAPY; DOSE-ESCALATION; MEGAVOLTAGE CT; ORGAN MOTION;
D O I
10.1016/j.ijrobp.2008.06.1926
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the feasibility, reproducibility, and accuracy of volumetric lung image guidance using different thoracic landmarks for image registration. Methods and Materials: In 30 lung patients, four independent observers conducted automated and manual image registrations on Day 1 cone-beam computed tomography data sets using the spine, carina, and tumor (720 image registrations). The image registration was timed, and the couch displacements were recorded. The intraclass correlation was used to assess reproducibility, and the Bland-Altman analysis was used to compare the automatic and manual matching methods. Tumor coverage (accuracy) was assessed through grading the tumor position after image matching against the internal target volume and planning target volume. Results: The image-guided process took an average of 1 min for all techniques, with the exception of manual tumor matching, which took 4 min. Reproducibility was greatest for automatic carina matching (intraclass correlation, 0.90-0.93) and lowest for manual tumor matching (intraclass correlation, 0.07-0.43) in the left-right, superoinferior, and anteroposterior directions, respectively. The Bland-Altman analysis showed no significant difference between the automatic and manual registration methods. The tumor was within the internal target volume 62% and 60% of the time and was outside the internal target volume, but within the planning target volume, 38% and 40% of the time after automatic spine and automatic carina matching, respectively. Conclusion: For advanced lung cancer, the spine or carina can be used equally for cone-beam computed tomography image registration without compromising target coverage. The carina was more reproducible than the spine, but additional analysis is required to confirm its validation as a tumor surrogate. Soft-tissue registration is unsuitable at present, given the limitations in contrast resolution and the high interobserver variability. (C) 2009 Elsevier Inc.
引用
收藏
页码:1404 / 1413
页数:10
相关论文
共 36 条
  • [11] Review of image-guided radiation therapy
    Jaffray, David
    Kupelian, Patrick
    Djemil, Toufik
    Macklis, Roger M.
    [J]. EXPERT REVIEW OF ANTICANCER THERAPY, 2007, 7 (01) : 89 - 103
  • [12] Serial megavoltage CT imaging during external beam radiotherapy for non-small-cell lung cancer: Observations on tumor regression during treatment
    Kupelian, PA
    Ramsey, C
    Meeks, SL
    Willoughby, TR
    Forbes, A
    Wagner, TH
    Langen, KM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04): : 1024 - 1028
  • [13] Has 3-D conformal radiotherapy (3D CRT) improved the local tumour control for stage I non-small cell lung cancer?
    Lagerwaard, FJ
    Senan, S
    van Meerbeeck, JP
    Graveland, WJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2002, 63 (02) : 151 - 157
  • [14] Cone-beam-CT guided radiation therapy:: technical implementation
    Létourneau, D
    Wong, JW
    Oldham, M
    Gulam, M
    Watt, L
    Jaffray, DA
    Siewerdsen, JH
    Martinez, AA
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 279 - 286
  • [15] Retrospective evaluation of setup reproducibility for thoracic and upper gastrointestinal radiotherapy through volumetric imaging: Stability and dependence on immobilization
    Li, W.
    Moseley, D.
    Bissonnette, J.
    Le, L.
    Purdie, T.
    Bezjak, A.
    Kim, J.
    Jaffray, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S507 - S508
  • [16] X-ray volumetric imaging in image-guided radiotherapy: The new standard in on-treatment imaging
    McBain, CA
    Henry, AM
    Sykes, J
    Amer, A
    Marchant, T
    Moore, CM
    Davies, J
    Stratford, J
    McCarthy, C
    Porritt, B
    Williams, P
    Khoo, VS
    Price, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02): : 625 - 634
  • [17] Comparison of localization performance with implanted fiducial markers and cone-beam computed tomography for on-line image-guided radiotherapy of the prostate
    Moseley, Douglas J.
    White, Elizabeth A.
    Wiltshire, Kirsty L.
    Rosewall, Tara
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Bissonnette, Jean-Pierre
    Gospodarowicz, Mary
    Warde, Padraig
    Catton, Charles N.
    Jaffray, David A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 942 - 953
  • [18] Cone-beam computed tomography for on-line image guidance of lung stereotactic radiotherapy: Localization, verification, and intrafraction tumor position
    Purdie, Thomas G.
    Bissonnette, Jean-Pierre
    Franks, Kevin
    Bezjak, Andrea
    Payne, David
    Sie, Fanny
    Sharpe, Michael B.
    Jaffray, David A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 243 - 252
  • [19] A technique for adaptive image-guided helical tomotherapy for lung cancer
    Ramsey, CR
    Langen, KM
    Kupelian, PA
    Scaperoth, DD
    Meeks, SL
    Mahan, SL
    Seibert, RM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04): : 1237 - 1244
  • [20] Improved local control with higher doses of radiation in large-volume stage III non-small-cell lung cancer
    Rengan, R
    Rosenzweig, KE
    Venkatraman, E
    Koutcher, LA
    Fox, JL
    Nayak, R
    Amols, H
    Yorke, E
    Jackson, A
    Ling, CC
    Leibel, SA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 741 - 747