Synchronous-frame current control of multiphase synchronous motor under asymmetric fault condition due to open phases

被引:141
作者
Ryu, Hyung-Min [1 ]
Kim, Ji-Woong
Sul, Seung-Ki
机构
[1] INTECH Factory Automat Co, Automat Lab, Seongnamsi 463810, South Korea
[2] LG Elect Co, Digital Appliance Res Lab, Seoul 152848, South Korea
[3] Seoul Natl Univ, Sch Elect Engn & Comp Sci, Seoul 151744, South Korea
关键词
asymmetric fault condition; multiphase motor; synchronous-frame current controller;
D O I
10.1109/TIA.2006.876074
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, a synchronous-frame current controller of a multiphase synchronous motor with open phases is proposed. The proposed method cannot only possess the superiority of a linear controller over the conventional hysteresis-type current controller but it also enables the current to be regulated without a steady-state error. The key idea is that all the harmonics of the current and voltage, which can still contribute to the torque positively, can be equivalently represented as dc components even under asymmetric fault conditions. Throughout this paper, a five-phase synchronous motor with one open phase is used as a practical example, and the basic concepts can be easily extended into an n-phase ac motor with multiple open phases, which has the arbitrary number or configuration of the remaining healthy phases. Experimental results prove the validity of the proposed modeling and control algorithm.