Novel composite material for selective copper(II) detection and removal from aqueous media

被引:268
作者
Awual, Md. Rabiul [1 ,2 ,3 ]
Hasan, Md. Munjur [4 ]
Rahman, Mohammed M. [2 ]
Asiri, Abdullah M. [2 ]
机构
[1] Japan Atom Energy Agcy SPring8, Mat Sci & Res Ctr, Tokai, Hyogo 6795148, Japan
[2] King Abdulaziz Univ, Fac Sci, Ctr Excellence Adv Mat Res, Jeddah 21589, Saudi Arabia
[3] Curtin Univ, Dept Chem Engn, GPO Box U1987, Perth, WA 6845, Australia
[4] Jessore Univ Sci & Technol, Fac Engn & Technol, Dept Petr & Min Engn, Jessore, Bangladesh
基金
日本学术振兴会;
关键词
Mesoporous composite material; Copper(II) ion; Sensitive detection and removal; High adsorption; Regeneration; GLASSY-CARBON ELECTRODE; EFFICIENT SELENIUM(IV) DETECTION; TRACE PALLADIUM(II) DETECTION; TUNING MESOPOROUS ADSORBENT; NANO-CONJUGATE ADSORBENT; HEAVY-METAL IONS; WASTE-WATER; SENSOR DEVELOPMENT; GRAPHENE OXIDE; LEAD(II) IONS;
D O I
10.1016/j.molliq.2019.03.141
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The mesoporous composite material (MeCM) was fabricated using functional organic ligand of 2-methy1-8-quinolinol immobilization onto the porous silica by direct conjugation and employed as an effective material for the detection and removal of copper (Cu(II)) ion from aqueous media. The material characterization was evaluated in detail to understand the material morphology for complexation during the Cu(II) ion capturing. The variation of pH solution, reaction time, detection limit, initial Cu(II) concentration and competing ion parameters were measured systematically. The MeCM was sensitively evolved the color upon addition of Cu(II) ion even in the low concentration level. The detection limit was 0.33 mu g/L. The solution pH was highly influenced both in the detection and adsorption operation. However, the neutral pH 7.0 was effective for efficient detection and removal of Cu(II) ion. The application of MeCM was significantly enhanced the removal capacity as well as selectivity. The Langmuir isotherm model was applied to validate the adsorption isotherms as the MeCM exhibited the homogeneous ordered frameworks. The adsorption capacity was 197.15 mg/g as expected due to the high surface area of MeCM even after ligand immobilization onto the porous silica. The competing ion was not affected significantly during the Cu(II) ion detection and removal because of the high affinity Cu(II) ion to MeCM at this optimum experimental protocol. Moreover, the Cu(II) ion was desorbed from the MeCM with using 0.20 M HCl and able to reuse in several cycles without deterioration in its original performances. Therefore, the designing method with experimental condition makes the MeCM to adopt for various environmental applications dealing with monitoring and separation processes. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:772 / 780
页数:9
相关论文
共 120 条
  • [1] A ligand anchored conjugate adsorbent for effective mercury(II) detection and removal from aqueous media
    Abbas, Khalid
    Znad, Hussein
    Awual, Md. Rabiul
    [J]. CHEMICAL ENGINEERING JOURNAL, 2018, 334 : 432 - 443
  • [2] One-step wet-chemical synthesis of ternary ZnO/CuO/Co3O4 nanoparticles for sensitive and selective melamine sensor development
    Alam, M. M.
    Asiri, Abdullah M.
    Uddin, M. T.
    Inamuddin
    Islam, M. A.
    Awual, Md. Rabiul
    Rahman, Mohammed M.
    [J]. NEW JOURNAL OF CHEMISTRY, 2019, 43 (12) : 4849 - 4858
  • [3] Ultra-sensitive 2-nitrophenol detection based on reduced graphene oxide/ZnO nanocomposites
    Alam, Mohammad K.
    Rahman, Mohammed M.
    Abbas, Mohamed
    Torati, Sri Ramulu
    Asiri, Abdullah M.
    Kim, Dojin
    Kim, CheolGi
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 66 - 73
  • [4] Ali M, 2001, INDIAN J FIBRE TEXT, V26, P414
  • [5] Equilibrium, thermodynamic and kinetic studies on biosorption of Pb(II) and Cd(II) from aqueous solution by macrofungus (Lactarius scrobiculatus) biomass
    Anayurt, Ruhan Altun
    Sari, Ahmet
    Tuzen, Mustafa
    [J]. CHEMICAL ENGINEERING JOURNAL, 2009, 151 (1-3) : 255 - 261
  • [6] [Anonymous], 2008, SOC CHEM IND
  • [7] [Anonymous], 1963, International standards for drinking-water
  • [8] Fabrication of cadmium ionic sensor based on (E)-4-Methyl-N′-(1-(pyridin-2-yl)ethylidene)benzenesulfonohydrazide (MPEBSH) by electrochemical approach
    Arshad, Muhammad Nadeem
    Sheikh, Tahir Ali
    Rahman, Mohammed M.
    Asiri, Abdullah M.
    Marwani, Hadi M.
    Awual, Md. Rabiul
    [J]. JOURNAL OF ORGANOMETALLIC CHEMISTRY, 2017, 827 : 49 - 55
  • [9] Evaluating of arsenic(V) removal from water by weak-base anion exchange adsorbents
    Awual, M. Rabiul
    Hossain, M. Amran
    Shenashen, M. A.
    Yaita, Tsuyoshi
    Suzuki, Shinichi
    Jyo, Akinori
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (01) : 421 - 430
  • [10] Arsenate removal from water by a weak-base anion exchange fibrous adsorbent
    Awual, Md. Rabiul
    Urata, Shinya
    Jyo, Akinori
    Tamada, Masao
    Katakai, Akio
    [J]. WATER RESEARCH, 2008, 42 (03) : 689 - 696