Influence of intrafraction motion on margins for prostate radiotherapy

被引:173
作者
Litzenberg, DW
Balter, JM
Hadley, SW
Sandler, HM
Willoughby, TR
Kupelian, PA
Levine, L
机构
[1] Univ Michigan Hlth Syst, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] MD Anderson Canc Ctr, Orlando, FL USA
[3] Calypso Med Technol, Seattle, WA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 65卷 / 02期
关键词
prostate cancer; intrafraction motion; margins; setup correction; organ motion;
D O I
10.1016/j.ijrobp.2005.12.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the impact of intrafraction intervention on margins for prostate radiotherapy. Methods and Materials: Eleven supine prostate patients with three implanted transponders were studied. The relative transponder positions were monitored for 8 min and combined with previously measured data on prostate position relative to skin marks. Margins were determined for situations of (1) skin-based positioning, and (2) pretreatment transponder positioning. Intratreatment intervention was simulated assuming conditions of (1) continuous tracking, and (2) a 3-mm threshold for position correction. Results: For skin-based setup without and with inclusion of intrafraction motion, prostate treatments would have required average margins of 8.0, 7.3, and 10.0 mm and 8.2, 10.2, and 12.5 mm, about the left-right, anterior-posterior, and cranial-caudal directions, respectively. Positioning by prostate markers at the start of the treatment fraction reduced these values to 1.8, 5.8, and 7.1 mm, respectively. Interbeam adjustment further reduced margins to an average of 1.4, 2.3, and 1.8 mm. Intrabeam adjustment yielded margins of 1.3, 1.5, and 1.5 mm, respectively. Conclusion: Significant reductions in margins might be achieved by repositioning the patient before each beam, either radiographically or electromagnetically. However, 2 of the 11 patients would have benefited from continuous target tracking and threshold-based intervention. (c) 2006 Elsevier Inc.
引用
收藏
页码:548 / 553
页数:6
相关论文
共 35 条
[11]   Target position variability throughout prostate radiotherapy [J].
Dawson, LA ;
Mah, K ;
Franssen, E ;
Morton, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (05) :1155-1161
[12]   The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy [J].
Dawson, LA ;
Brock, KK ;
Kazanjian, S ;
Fitch, D ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK ;
Balter, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1410-1421
[13]   A comparison of ventilatory prostate movement in four treatment positions [J].
Dawson, LA ;
Litzenberg, DW ;
Brock, KK ;
Sanda, M ;
Sullivan, M ;
Sandler, HM ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :319-323
[14]   A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload [J].
De Boer, HCJ ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1350-1365
[15]   Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions [J].
Kitamura, K ;
Shirato, H ;
Seppenwoolde, Y ;
Onimaru, R ;
Oda, M ;
Fujita, K ;
Shimizu, S ;
Shinohara, N ;
Harabayashi, T ;
Miyasaka, K .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1117-1123
[16]   IMPROVEMENT OF PRECISION IN SPATIAL LOCALIZATION OF RADIO-OPAQUE MARKERS USING THE 2-FILM TECHNIQUE [J].
LAM, KL ;
TENHAKEN, RK .
MEDICAL PHYSICS, 1991, 18 (06) :1126-1131
[17]   AUTOMATED-DETERMINATION OF PATIENT SETUP ERRORS IN RADIATION-THERAPY USING SPHERICAL RADIO-OPAQUE MARKERS [J].
LAM, KL ;
TENHAKEN, RK ;
MCSHAN, DL ;
THORNTON, AF .
MEDICAL PHYSICS, 1993, 20 (04) :1145-1152
[18]   Daily prostate targeting using implanted radiopaque markers [J].
Litzenberg, D ;
Dawson, LA ;
Sandler, H ;
Sanda, MG ;
McShan, D ;
Ten Haken, RK ;
Lam, KL ;
Brock, KK ;
Balter, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (03) :699-703
[19]  
Mageras G S, 2001, J Appl Clin Med Phys, V2, P191, DOI 10.1120/1.1409235
[20]   Measurement of intrafractional prostate motion using magnetic resonance imaging [J].
Mah, D ;
Freedman, G ;
Milestone, B ;
Hanlon, A ;
Palacio, E ;
Richardson, T ;
Movsas, B ;
Mitra, R ;
Horwitz, E ;
Hanks, GE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (02) :568-575