Influence of intrafraction motion on margins for prostate radiotherapy

被引:172
作者
Litzenberg, DW
Balter, JM
Hadley, SW
Sandler, HM
Willoughby, TR
Kupelian, PA
Levine, L
机构
[1] Univ Michigan Hlth Syst, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] MD Anderson Canc Ctr, Orlando, FL USA
[3] Calypso Med Technol, Seattle, WA USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2006年 / 65卷 / 02期
关键词
prostate cancer; intrafraction motion; margins; setup correction; organ motion;
D O I
10.1016/j.ijrobp.2005.12.033
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the impact of intrafraction intervention on margins for prostate radiotherapy. Methods and Materials: Eleven supine prostate patients with three implanted transponders were studied. The relative transponder positions were monitored for 8 min and combined with previously measured data on prostate position relative to skin marks. Margins were determined for situations of (1) skin-based positioning, and (2) pretreatment transponder positioning. Intratreatment intervention was simulated assuming conditions of (1) continuous tracking, and (2) a 3-mm threshold for position correction. Results: For skin-based setup without and with inclusion of intrafraction motion, prostate treatments would have required average margins of 8.0, 7.3, and 10.0 mm and 8.2, 10.2, and 12.5 mm, about the left-right, anterior-posterior, and cranial-caudal directions, respectively. Positioning by prostate markers at the start of the treatment fraction reduced these values to 1.8, 5.8, and 7.1 mm, respectively. Interbeam adjustment further reduced margins to an average of 1.4, 2.3, and 1.8 mm. Intrabeam adjustment yielded margins of 1.3, 1.5, and 1.5 mm, respectively. Conclusion: Significant reductions in margins might be achieved by repositioning the patient before each beam, either radiographically or electromagnetically. However, 2 of the 11 patients would have benefited from continuous target tracking and threshold-based intervention. (c) 2006 Elsevier Inc.
引用
收藏
页码:548 / 553
页数:6
相关论文
共 35 条
  • [1] Balter J. M., 2000, International Journal of Radiation Oncology Biology Physics, V48, P167, DOI 10.1016/S0360-3016(00)80129-7
  • [2] Accuracy of a wireless localization system for radiotherapy
    Balter, JM
    Wright, JN
    Newell, LJ
    Friemel, B
    Dimmer, S
    Cheng, Y
    Wong, J
    Vertatschitsch, E
    Mate, TP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 933 - 937
  • [3] Daily targeting of intrahepatic tumors for radiotherapy
    Balter, JM
    Brock, KK
    Litzenberg, DW
    McShan, DL
    Lawrence, TS
    Ten Haken, R
    McGinn, CJ
    Lam, KL
    Dawson, LA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01): : 266 - 271
  • [4] ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS
    BALTER, JM
    CHEN, GTY
    PELIZZARI, CA
    KRISHNASAMY, S
    RUBIN, S
    VIJAYAKUMAR, S
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (01): : 137 - 143
  • [5] Determination of ventilatory liver movement via radiographic evaluation of diaphragm position
    Balter, JM
    Dawson, LA
    Kazanjian, S
    McGinn, C
    Brock, KK
    Lawrence, T
    Ten Haken, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01): : 267 - 270
  • [6] High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging
    Bel, A
    Vos, PH
    Rodrigus, PTR
    Creutzberg, CL
    Visser, AG
    Stroom, JC
    Lebesque, JV
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02): : 321 - 332
  • [7] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [8] Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors
    Berbeco, RI
    Jiang, SB
    Sharp, GC
    Chen, GTY
    Mostafavi, H
    Shirato, H
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) : 243 - 255
  • [9] Fluoroscopic study of tumor motion due to breathing: Facilitating precise radiation therapy for lung cancer patients
    Chen, QS
    Weinhous, MS
    Deibel, FC
    Ciezki, JP
    Macklis, RM
    [J]. MEDICAL PHYSICS, 2001, 28 (09) : 1850 - 1856
  • [10] Interventions to reduce organ motion effects in radiation delivery
    Dawson, LA
    Balter, AM
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2004, 14 (01) : 76 - 80